Geophysical, Geochemical, and Mineralogical Data from the Pebble Cu-Au-Mo Porphyry Deposit Area, Southwest Alaska: Contributions to Assessment Techniques for Concealed Mineral Resources

Metadata also available as

Frequently anticipated questions:


What does this data set describe?

Title:
Geophysical, Geochemical, and Mineralogical Data from the Pebble Cu-Au-Mo Porphyry Deposit Area, Southwest Alaska: Contributions to Assessment Techniques for Concealed Mineral Resources
Abstract:
The Microsoft Access database serves as a geochemical data warehouse in support of the Pebble Deposit Project, and contains data tables describing quantitative and qualitative geochemical analyses determined by 51 analytical laboratory and field methods for 4,035 sediment, soil, heavy-mineral concentrate, rock and vegetation samples, all of which were collected by USGS personnel and analyzed either in the analytical laboratories of the Geologic Discipline of the USGS or by contract with commercial analytical laboratories.
Supplemental_Information:
Tabular datafiles included in this dataset are: PebbleGeochem.mdb
  1. How should this data set be cited?

    U.S. Geological Survey (USGS), 2011, Geophysical, Geochemical, and Mineralogical Data from the Pebble Cu-Au-Mo Porphyry Deposit Area, Southwest Alaska: Contributions to Assessment Techniques for Concealed Mineral Resources: U.S. Geological Survey Data Series 608, U.S. Geological Survey, Denver, CO.

    Online Links:

  2. What geographic area does the data set cover?

    West_Bounding_Coordinate: -155.68426
    East_Bounding_Coordinate: -155.03283
    North_Bounding_Coordinate: 60.03541
    South_Bounding_Coordinate: 59.7293

  3. What does it look like?

  4. Does the data set describe conditions during a particular time period?

    Beginning_Date: 2007
    Ending_Date: 2011
    Currentness_Reference: sample collection and analysis period

  5. What is the general form of this data set?

    Geospatial_Data_Presentation_Form: tabular data

  6. How does the data set represent geographic features?

    1. How are geographic features stored in the data set?

      This is a point data set. It contains the following vector data types (SDTS terminology):

      • point (446)

    2. What coordinate system is used to represent geographic features?

      Horizontal positions are specified in geographic coordinates, that is, latitude and longitude. Latitudes are given to the nearest 0.00001. Longitudes are given to the nearest 0.00001. Latitude and longitude values are specified in decimal degrees.

  7. How does the data set describe geographic features?

    Entity_and_Attribute_Overview:
    The AnalyticMethod table is a table of analytic methods used to obtain chemical and physical data for the Pebble project.
    FieldName                 FieldType   FieldSize-Format   FieldDescript
    
    AnalyticMethodShortName   Text        15                 Short name of analytic method.
    AnalyticMethodDesc        Text        200                Full description of analytic method.
    AnalyzedMedia             Text        10                 Media analyzed by specific method.
    LabShortName              Text        15                 Short name of laboratory that performed analysis.
    AnalMethPub_ID            Text        50                 Unique ID for analytic method publication; usually USGS Library call number for reference of analytic method.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The AnalyticMethodBiblio table is a table of references for analytic methods used to obtain chemical data utilized in the Pebble project
    FieldName                 FieldType   FieldSize-Format   FieldDescript
    
    AnalMethPub_ID            Text        50                 Unique ID for analytic method publication; usually USGS Library call number for reference of analytic method.
    AnalMethPub_Author        Text        255                Analytic method publication author(s).
    AnalMethPub_Year          Number      Long Integer       Year of analytic method publication.
    AnalMethPub_Title         Text        255                Title of analytic method publication.
    AnalMethPub_SeriesTitle   Text        150                Series title of analytic method publication.
    AnalMethPub_Pages         Text        100                Pages in analytic method publication.
    AnalMethPub_URL           Hyperlink                      URL of analytic method publication, if available.
    AnalMethPub_Notes         Memo        65,535             Notes regarding analytic method publication.
    AnalMethPub_Citation      Memo        65,535             Full citation of analytic method publication.
    LabShortName              Text        15                 Short name of laboratory that performed analysis.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table FieldNameDictionary is a table of field name descriptions for all tables in the Pebble project database.
    FieldName          FieldType   FieldSize-Format   FieldDescript
    
    FieldName          Text        50                 Field name populated in one or more tables in Pebble database.
    FieldType          Text        15                 Data type of field.
    FieldSize-Format   Text        15                 Maximum number of characters, or format of data, that can be entered in field.
    FieldDescript      Text        255                Description of field.
    FieldTables        Memo        65,535             Table(s) containing field.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table FieldSite is a table of spatial and descriptive attributes for field sites in the Pebble project.
    FieldName                    FieldType   FieldSize-Format   FieldDescript
    
    FieldSiteNumber              Text        15                 Unique field site ID assigned by scientist in the field.
    FieldSiteNumber_Coincident   Text        50                 Site IDs for sites co-located at this spot; from different sample collectors or re-sample at different time period.
    FieldLatitude_DD             Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD            Number      Decimal            Longitude from field, in decimal degrees.
    FieldLatitude_DMS            Text        20                 Latitude from field, in degrees, minutes and seconds.
    FieldLongitude_DMS           Text        20                 Longitude from field, in degrees, minutes and seconds.
    FieldCoordDatum              Text        10                 Datum used to determine Lat/Long from field.
    FieldCoordSpheroid           Text        10                 Spheroid used to determine Lat/Long from field.
    FieldCoordEPE                Number      Double             Estimated Position Error (EPE), in feet; measure of uncertainty of a position measurement given by higher quality GPS units.
    FieldCoordNo_Satellites      Number      Long Integer       Number of satellites for the GPS location fix.
    FieldCoordMethod             Text        25                 Method in which the latitude/longitude were determined: GPS, digitized from topo, other (state method).
    FieldElevation               Number      Double             Elevation, determined in the field for site (above mean sea level), in feet.
    ElevationMethod              Text        25                 Method used to determine elevation: GPS, altimeter, topo map.
    Quad_63K_Name                Text        25                 Name of 1:63,360 scale quadrangle in which sample site is located.
    State_Province               Text        20                 State or province, 2-letter postal state code if applicable.
    SiteDesc                     Memo        65,535             Descriptive information for site.
    SiteLocationInfo             Text        150                Site-specific location information.
    SiteComment                  Memo        65,535             Any other site-related information that was not captured elsewhere.
    AirTemperature               Number      Double             Air temperature at site, in degrees Celsius.
    RelativeHumidity             Number      Double             Relative humidity at site, in percent.
    Weather                      Text        100                Weather at time site was visited/samples were collected.
    SiteBedrockGeolDesc          Memo        65,535             Brief description of the bedrock geology of the site, regardless of the type of sample collected there.
    MiningDistrict               Text        25                 Name of mining district; if site is not in an organized mining district then state "none;" if unknown, then state "unknown".
    DepositName                  Text        50                 Name of mine, prospect or deposit; if more than one name, list them all separated by commas.
    DepositTypeDesc              Text        50                 Description of deposit type, such as "volcanogenic massive sulfide" or "porphyry copper."
    ContaminationAtSite          Text        150                Presence and type of any man-made potential contaminants visible at site or just upstream.
    FieldSitePubl_Code           Text        25                 U.S. Geological Survey publication code.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table H2O_Alk is a table of alkalinity data for unacidified water samples collected and analyzed for the Pebble project.
    FieldName             FieldType   FieldSize-Format   FieldDescript
    
    SampleID              Number      Long Integer       Unique sample identifier.
    SampleNumber          Text        20                 Sample number provided by submitter.
    FieldSiteNumber       Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID                Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID                Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD      Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD     Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName          Text        15                 Short name of laboratory that performed analysis.
    QA-QC                 Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed        Text        100                Description of actual sample analyzed.
    Alk-CaCO3_mg/L_Titr   Number      Double             Alkalinity, as calcium carbonate, in milligrams per liter, by acid titration.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table H2O_Anions is a table of anion data for unacidified water samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Cl_mg/L_IC          Number      Double             Chloride, in milligrams per liter, determined by ion chromatography.
    F_mg/L_IC           Number      Double             Fluoride, in milligrams per liter, determined by ion chromatography.
    NO3_mg/L_IC         Number      Double             Nitrate, in milligrams per liter, determined by ion chromatography.
    SO4_mg/L_IC         Number      Double             Sulfate, in milligrams per liter, determined by ion chromatography.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table H2O_DOC is a table of dissolved organic carbon data for acidified water samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    C-Org_mg/L_Comb     Number      Double             Organic carbon, dissolved, in milligrams per liter, by carbon analyzer using an infrared detector.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table H2O_Fe is a table of ferrous iron data for acidified water samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Fe(II)_ug/L_CM      Number      Double             Ferrous iron, in micrograms per liter, by visible spectrometry (ferrozine) or spectrophotometry, in the lab.
    Fe(III)_ug/L_Comp   Number      Double             Ferric iron, in micrograms per liter, by the calculated difference between total iron and ferrous iron.
    Fe_ug/L_CM          Number      Double             Iron, in micrograms per liter, by visible spectrometry (ferrozine) or spectrophotometry, in the lab.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table H2O_FldChem is a table of field chemistry data for unacidified water samples collected and analyzed for the Pebble project.
    FieldName               FieldType   FieldSize-Format   FieldDescript
    
    SampleID                Number      Long Integer       Unique sample identifier.
    SampleNumber            Text        20                 Sample number provided by submitter.
    FieldSiteNumber         Text        15                 Unique field site ID assigned by scientist in the field.
    FieldLatitude_DD        Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD       Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName            Text        15                 Short name of laboratory that performed analysis.
    QA-QC                   Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed          Text        100                Description of actual sample analyzed.
    Acid_mg/L_Fld           Number      Double             Acidity, in milligrams per liter, in the field with a field titration kit, performed on most samples with pH < 7.
    Alk-CaCO3_mg/L_Fld      Number      Double             Alkalinity, as calcium carbonate, in milligrams per liter, in the field by acid titration.
    Color-H2O_Fld           Text        50                 Color of water, in the field.
    Filters_Fld             Number      Double             Number of filters used, in the field
    O2_mg/L_Fld             Number      Double             Oxygen, dissolved, in water, in milligrams per liter, in the field using an electrode.
    Odor_Fld                Text        50                 Water odor, in the field.
    pH_SI_Fld               Number      Double             pH of water, in standard units, by digital pH meter in the field.
    Qinstant-Calc_Lpm_Fld   Number      Double             Stream discharge, instantaneous, in liters per minute, calculated in the field.
    Qinstant-Est_cfs_Fld    Number      Double             Stream discharge, instantaneous, in cubic feet per second, estimated in the field.
    Qinstant-Est_Lpm_Fld    Number      Double             Stream discharge, instantaneous, in liters per minute, estimated in the field.
    SpCon_uS/cm_Fld         Number      Double             Specific conductivity of water, in micro-Siemens per centimeter, in the field.
    Temp_degC_Fld           Number      Double             Temperature of water, in degrees Celsius, in the field.
    Turbid_FTU_Fld          Number      Double             Turbidity, in formazine turbidity units, in the field with a turbidity meter, using an infrared LED light source.
    Turbid_NTU_Fld          Number      Double             Turbidity, in nephelometric turbidity units, in the field with a turbidity meter, using an infrared LED light source.
    Turbid-Qual_Fld         Text        50                 Turbidity, as qualitative comment, in the field.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table H2O_Hg is a table of mercury data for acidified water samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Hg_ug/L_AA          Number      Double             Mercury, in micrograms per liter, by cold vapor atomic absorption spectrophotometry.
    Hg_ug/L_AF          Number      Double             Mercury, in micrograms per liter, by cold vapor atomic fluorescence spectroscopy.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table H2O_ICPAES-FA is a table of inductively coupled plasma-atomic emission spectroscopy chemical data for filtered, acidified water samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ug/L_AES         Number   Double                Silver, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Al_ug/L_AES         Number   Double                Aluminum, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    As_ug/L_AES         Number   Double                Arsenic, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    B_ug/L_AES          Number   Double                Boron, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Ba_ug/L_AES         Number   Double                Barium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Be_ug/L_AES         Number   Double                Beryllium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Ca_mg/L_AES         Number   Double                Calcium, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Cd_ug/L_AES         Number   Double                Cadmium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Co_ug/L_AES         Number   Double                Cobalt, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Cr_ug/L_AES         Number   Double                Chromium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Cu_ug/L_AES         Number   Double                Copper, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Fe_ug/L_AES         Number   Double                Iron, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    K_mg/L_AES          Number   Double                Potassium, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Li_ug/L_AES         Number   Double                Lithium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Mg_mg/L_AES         Number   Double                Magnesium, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Mn_ug/L_AES         Number   Double                Manganese, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Mo_ug/L_AES         Number   Double                Molybdenum, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Na_mg/L_AES         Number   Double                Sodium, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Ni_ug/L_AES         Number   Double                Nickel, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    P_mg/L_AES          Number   Double                Phosphorus, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Pb_ug/L_AES         Number   Double                Lead, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Sb_ug/L_AES         Number   Double                Antimony, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Se_ug/L_AES         Number   Double                Selenium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    SiO2_mg/L_AES       Number   Double                Silicon, as silicon dioxide, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    SO4_mg/L_AES        Number   Double                Sulfate, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Sr_ug/L_AES         Number   Double                Strontium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Ti_ug/L_AES         Number   Double                Titanium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    V_ug/L_AES          Number   Double                Vanadium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Zn_ug/L_AES         Number   Double                Zinc, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table H2O_ICPAES-RA is a table of inductively coupled plasma-atomic emission spectroscopy chemical data for unfiltered, acidified water samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ug/L_AES         Number      Double             Silver, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Al_ug/L_AES         Number      Double             Aluminum, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    As_ug/L_AES         Number      Double             Arsenic, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    B_ug/L_AES          Number      Double             Boron, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Ba_ug/L_AES         Number      Double             Barium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Be_ug/L_AES         Number      Double             Beryllium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Ca_mg/L_AES         Number      Double             Calcium, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Cd_ug/L_AES         Number      Double             Cadmium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Co_ug/L_AES         Number      Double             Cobalt, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Cr_ug/L_AES         Number      Double             Chromium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Cu_ug/L_AES         Number      Double             Copper, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Fe_ug/L_AES         Number      Double             Iron, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    K_mg/L_AES          Number      Double             Potassium, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Li_ug/L_AES         Number      Double             Lithium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Mg_mg/L_AES         Number      Double             Magnesium, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Mn_ug/L_AES         Number      Double             Manganese, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Mo_ug/L_AES         Number      Double             Molybdenum, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Na_mg/L_AES         Number      Double             Sodium, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Ni_ug/L_AES         Number      Double             Nickel, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    P_mg/L_AES          Number      Double             Phosphorus, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Pb_ug/L_AES         Number      Double             Lead, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Sb_ug/L_AES         Number      Double             Antimony, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Se_ug/L_AES         Number      Double             Selenium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    SiO2_mg/L_AES       Number      Double             Silicon, as silicon dioxide, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    SO4_mg/L_AES        Number      Double             Sulfate, in milligrams per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Sr_ug/L_AES         Number      Double             Strontium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Ti_ug/L_AES         Number      Double             Titanium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    V_ug/L_AES          Number      Double             Vanadium, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    Zn_ug/L_AES         Number      Double             Zinc, in micrograms per liter, by inductively coupled plasma-atomic emission spectroscopy.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table H2O_ICPMS-FA is a table of inductively coupled plasma-mass spectroscopy chemical data for filtered, acidified water samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ug/L_MS          Number      Double             Silver, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Al_ug/L_MS          Number      Double             Aluminum, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    As_ug/L_MS          Number      Double             Arsenic, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ba_ug/L_MS          Number      Double             Barium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Be_ug/L_MS          Number      Double             Beryllium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Bi_ug/L_MS          Number      Double             Bismuth, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ca_mg/L_MS          Number      Double             Calcium, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    Cd_ug/L_MS          Number      Double             Cadmium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ce_ug/L_MS          Number      Double             Cerium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Co_ug/L_MS          Number      Double             Cobalt, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Cr_ug/L_MS          Number      Double             Chromium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Cs_ug/L_MS          Number      Double             Cesium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Cu_ug/L_MS          Number      Double             Copper, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Dy_ug/L_MS          Number      Double             Dysprosium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Er_ug/L_MS          Number      Double             Erbium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Eu_ug/L_MS          Number      Double             Europium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Fe_ug/L_MS          Number      Double             Iron, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ga_ug/L_MS          Number      Double             Gallium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Gd_ug/L_MS          Number      Double             Gadolinium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ge_ug/L_MS          Number      Double             Germanium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ho_ug/L_MS          Number      Double             Holmium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    K_mg/L_MS           Number      Double             Potassium, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    La_ug/L_MS          Number      Double             Lanthanum, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Li_ug/L_MS          Number      Double             Lithium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Lu_ug/L_MS          Number      Double             Lutetium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Mg_mg/L_MS          Number      Double             Magnesium, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    Mn_ug/L_MS          Number      Double             Manganese, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Mo_ug/L_MS          Number      Double             Molybdenum, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Na_mg/L_MS          Number      Double             Sodium, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    Nb_ug/L_MS          Number      Double             Niobium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Nd_ug/L_MS          Number      Double             Neodymium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ni_ug/L_MS          Number      Double             Nickel, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    P_mg/L_MS           Number      Double             Phosphorus, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    Pb_ug/L_MS          Number      Double             Lead, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Pr_ug/L_MS          Number      Double             Praseodymium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Rb_ug/L_MS          Number      Double             Rubidium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Sb_ug/L_MS          Number      Double             Antimony, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Sc_ug/L_MS          Number      Double             Scandium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Se_ug/L_MS          Number      Double             Selenium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    SiO2_mg/L_MS        Number      Double             Silicon, as silicon dioxide, as silicon dioxide, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    Sm_ug/L_MS          Number      Double             Samarium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    SO4_mg/L_MS         Number      Double             Sulfate, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    Sr_ug/L_MS          Number      Double             Strontium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ta_ug/L_MS          Number      Double             Tantalum, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Tb_ug/L_MS          Number      Double             Terbium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Th_ug/L_MS          Number      Double             Thorium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ti_ug/L_MS          Number      Double             Titanium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Tl_ug/L_MS          Number      Double             Thallium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Tm_ug/L_MS          Number      Double             Thulium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    U_ug/L_MS           Number      Double             Uranium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    V_ug/L_MS           Number      Double             Vanadium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    W_ug/L_MS           Number      Double             Tungsten, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Y_ug/L_MS           Number      Double             Yttrium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Yb_ug/L_MS          Number      Double             Ytterbium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Zn_ug/L_MS          Number      Double             Zinc, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Zr_ug/L_MS          Number      Double             Zirconium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table H2O_ICPMS-HR-FA is a table of high resolution inductively coupled plasma-mass spectroscopy chemical data for filtered, acidified water samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ug/L_MS-HR       Number      Double             Silver, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Al_ug/L_MS-HR       Number      Double             Aluminum, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    As_ug/L_MS-HR       Number      Double             Arsenic, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Au_ug/L_MS-HR       Number      Double             Gold, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    B_ug/L_MS-HR        Number      Double             Boron, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ba_ug/L_MS-HR       Number      Double             Barium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Be_ug/L_MS-HR       Number      Double             Beryllium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Bi_ug/L_MS-HR       Number      Double             Bismuth, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ca_mg/L_MS-HR       Number      Double             Calcium, in milligrams per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Cd_ug/L_MS-HR       Number      Double             Cadmium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ce_ug/L_MS-HR       Number      Double             Cerium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Co_ug/L_MS-HR       Number      Double             Cobalt, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Cr_ug/L_MS-HR       Number      Double             Chromium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Cs_ug/L_MS-HR       Number      Double             Cesium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Cu_ug/L_MS-HR       Number      Double             Copper, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Dy_ug/L_MS-HR       Number      Double             Dysprosium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Er_ug/L_MS-HR       Number      Double             Erbium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Eu_ug/L_MS-HR       Number      Double             Europium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Fe_ug/L_MS-HR       Number      Double             Iron, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ga_ug/L_MS-HR       Number      Double             Gallium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Gd_ug/L_MS-HR       Number      Double             Gadolinium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ge_ug/L_MS-HR       Number      Double             Germanium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Hf_ug/L_MS-HR       Number      Double             Hafnium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Hg_ug/L_MS-HR       Number      Double             Mercury, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ho_ug/L_MS-HR       Number      Double             Holmium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    In_ug/L_MS-HR       Number      Double             Indium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    K_mg/L_MS-HR        Number      Double             Potassium, in milligrams per liter, by high resolution inductively coupled plasma-mass spectrometry.
    La_ug/L_MS-HR       Number      Double             Lanthanum, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Li_ug/L_MS-HR       Number      Double             Lithium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Lu_ug/L_MS-HR       Number      Double             Lutetium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Mg_mg/L_MS-HR       Number      Double             Magnesium, in milligrams per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Mn_ug/L_MS-HR       Number      Double             Manganese, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Mo_ug/L_MS-HR       Number      Double             Molybdenum, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Na_mg/L_MS-HR       Number      Double             Sodium, in milligrams per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Nb_ug/L_MS-HR       Number      Double             Niobium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Nd_ug/L_MS-HR       Number      Double             Neodymium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ni_ug/L_MS-HR       Number      Double             Nickel, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Pb_ug/L_MS-HR       Number      Double             Lead, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Pd_ug/L_MS-HR       Number      Double             Palladium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Pr_ug/L_MS-HR       Number      Double             Praseodymium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Pt_ug/L_MS-HR       Number      Double             Platinum, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Rb_ug/L_MS-HR       Number      Double             Rubidium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Re_ug/L_MS-HR       Number      Double             Rhenium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ru_ug/L_MS-HR       Number      Double             Ruthenium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Sb_ug/L_MS-HR       Number      Double             Antimony, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Sc_ug/L_MS-HR       Number      Double             Scandium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Se_ug/L_MS-HR       Number      Double             Selenium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Sm_ug/L_MS-HR       Number      Double             Samarium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Sn_ug/L_MS-HR       Number      Double             Tin, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Sr_ug/L_MS-HR       Number      Double             Strontium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ta_ug/L_MS-HR       Number      Double             Tantalum, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Tb_ug/L_MS-HR       Number      Double             Terbium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Te_ug/L_MS-HR       Number      Double             Tellurium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Th_ug/L_MS-HR       Number      Double             Thorium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ti_ug/L_MS-HR       Number      Double             Titanium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Tl_ug/L_MS-HR       Number      Double             Thallium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Tm_ug/L_MS-HR       Number      Double             Thulium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    U_ug/L_MS-HR        Number      Double             Uranium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    V_ug/L_MS-HR        Number      Double             Vanadium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    W_ug/L_MS-HR        Number      Double             Tungsten, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Y_ug/L_MS-HR        Number      Double             Yttrium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Yb_ug/L_MS-HR       Number      Double             Ytterbium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Zn_ug/L_MS-HR       Number      Double             Zinc, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Zr_ug/L_MS-HR       Number      Double             Zirconium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table H2O_ICPMS-HR-RA is a table of high resolution inductively coupled plasma-mass spectroscopy chemical data for unfiltered, acidified water samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ug/L_MS-HR       Number      Double             Silver, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Al_ug/L_MS-HR       Number      Double             Aluminum, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    As_ug/L_MS-HR       Number      Double             Arsenic, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Au_ug/L_MS-HR       Number      Double             Gold, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    B_ug/L_MS-HR        Number      Double             Boron, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ba_ug/L_MS-HR       Number      Double             Barium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Be_ug/L_MS-HR       Number      Double             Beryllium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Bi_ug/L_MS-HR       Number      Double             Bismuth, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ca_mg/L_MS-HR       Number      Double             Calcium, in milligrams per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Cd_ug/L_MS-HR       Number      Double             Cadmium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ce_ug/L_MS-HR       Number      Double             Cerium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Co_ug/L_MS-HR       Number      Double             Cobalt, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Cr_ug/L_MS-HR       Number      Double             Chromium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Cs_ug/L_MS-HR       Number      Double             Cesium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Cu_ug/L_MS-HR       Number      Double             Copper, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Dy_ug/L_MS-HR       Number      Double             Dysprosium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Er_ug/L_MS-HR       Number      Double             Erbium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Eu_ug/L_MS-HR       Number      Double             Europium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Fe_ug/L_MS-HR       Number      Double             Iron, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ga_ug/L_MS-HR       Number      Double             Gallium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Gd_ug/L_MS-HR       Number      Double             Gadolinium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ge_ug/L_MS-HR       Number      Double             Germanium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Hf_ug/L_MS-HR       Number      Double             Hafnium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Hg_ug/L_MS-HR       Number      Double             Mercury, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ho_ug/L_MS-HR       Number      Double             Holmium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    In_ug/L_MS-HR       Number      Double             Indium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    K_mg/L_MS-HR        Number      Double             Potassium, in milligrams per liter, by high resolution inductively coupled plasma-mass spectrometry.
    La_ug/L_MS-HR       Number      Double             Lanthanum, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Li_ug/L_MS-HR       Number      Double             Lithium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Lu_ug/L_MS-HR       Number      Double             Lutetium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Mg_mg/L_MS-HR       Number      Double             Magnesium, in milligrams per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Mn_ug/L_MS-HR       Number      Double             Manganese, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Mo_ug/L_MS-HR       Number      Double             Molybdenum, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Na_mg/L_MS-HR       Number      Double             Sodium, in milligrams per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Nb_ug/L_MS-HR       Number      Double             Niobium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Nd_ug/L_MS-HR       Number      Double             Neodymium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ni_ug/L_MS-HR       Number      Double             Nickel, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Pb_ug/L_MS-HR       Number      Double             Lead, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Pd_ug/L_MS-HR       Number      Double             Palladium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Pr_ug/L_MS-HR       Number      Double             Praseodymium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Pt_ug/L_MS-HR       Number      Double             Platinum, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Rb_ug/L_MS-HR       Number      Double             Rubidium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Re_ug/L_MS-HR       Number      Double             Rhenium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ru_ug/L_MS-HR       Number      Double             Ruthenium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Sb_ug/L_MS-HR       Number      Double             Antimony, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Sc_ug/L_MS-HR       Number      Double             Scandium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Se_ug/L_MS-HR       Number      Double             Selenium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Sm_ug/L_MS-HR       Number      Double             Samarium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Sn_ug/L_MS-HR       Number      Double             Tin, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Sr_ug/L_MS-HR       Number      Double             Strontium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ta_ug/L_MS-HR       Number      Double             Tantalum, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Tb_ug/L_MS-HR       Number      Double             Terbium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Te_ug/L_MS-HR       Number      Double             Tellurium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Th_ug/L_MS-HR       Number      Double             Thorium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Ti_ug/L_MS-HR       Number      Double             Titanium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Tl_ug/L_MS-HR       Number      Double             Thallium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Tm_ug/L_MS-HR       Number      Double             Thulium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    U_ug/L_MS-HR        Number      Double             Uranium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    V_ug/L_MS-HR        Number      Double             Vanadium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    W_ug/L_MS-HR        Number      Double             Tungsten, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Y_ug/L_MS-HR        Number      Double             Yttrium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Yb_ug/L_MS-HR       Number      Double             Ytterbium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Zn_ug/L_MS-HR       Number      Double             Zinc, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    Zr_ug/L_MS-HR       Number      Double             Zirconium, in micrograms per liter, by high resolution inductively coupled plasma-mass spectrometry.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table H2O_ICPMS-RA is a table of inductively coupled plasma-mass spectroscopy chemical data for unfiltered, acidified water samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ug/L_MS          Number      Double             Silver, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Al_ug/L_MS          Number      Double             Aluminum, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    As_ug/L_MS          Number      Double             Arsenic, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ba_ug/L_MS          Number      Double             Barium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Be_ug/L_MS          Number      Double             Beryllium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Bi_ug/L_MS          Number      Double             Bismuth, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ca_mg/L_MS          Number      Double             Calcium, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    Cd_ug/L_MS          Number      Double             Cadmium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ce_ug/L_MS          Number      Double             Cerium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Co_ug/L_MS          Number      Double             Cobalt, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Cr_ug/L_MS          Number      Double             Chromium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Cs_ug/L_MS          Number      Double             Cesium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Cu_ug/L_MS          Number      Double             Copper, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Dy_ug/L_MS          Number      Double             Dysprosium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Er_ug/L_MS          Number      Double             Erbium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Eu_ug/L_MS          Number      Double             Europium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Fe_ug/L_MS          Number      Double             Iron, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ga_ug/L_MS          Number      Double             Gallium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Gd_ug/L_MS          Number      Double             Gadolinium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ge_ug/L_MS          Number      Double             Germanium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ho_ug/L_MS          Number      Double             Holmium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    K_mg/L_MS           Number      Double             Potassium, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    La_ug/L_MS          Number      Double             Lanthanum, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Li_ug/L_MS          Number      Double             Lithium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Lu_ug/L_MS          Number      Double             Lutetium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Mg_mg/L_MS          Number      Double             Magnesium, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    Mn_ug/L_MS          Number      Double             Manganese, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Mo_ug/L_MS          Number      Double             Molybdenum, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Na_mg/L_MS          Number      Double             Sodium, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    Nb_ug/L_MS          Number      Double             Niobium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Nd_ug/L_MS          Number      Double             Neodymium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ni_ug/L_MS          Number      Double             Nickel, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    P_mg/L_MS           Number      Double             Phosphorus, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    Pb_ug/L_MS          Number      Double             Lead, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Pr_ug/L_MS          Number      Double             Praseodymium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Rb_ug/L_MS          Number      Double             Rubidium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Sb_ug/L_MS          Number      Double             Antimony, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Sc_ug/L_MS          Number      Double             Scandium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Se_ug/L_MS          Number      Double             Selenium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    SiO2_mg/L_MS        Number      Double             Silicon, as silicon dioxide, as silicon dioxide, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    Sm_ug/L_MS          Number      Double             Samarium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    SO4_mg/L_MS         Number      Double             Sulfate, in milligrams per liter, by inductively coupled plasma-mass spectrometry.
    Sr_ug/L_MS          Number      Double             Strontium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ta_ug/L_MS          Number      Double             Tantalum, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Tb_ug/L_MS          Number      Double             Terbium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Th_ug/L_MS          Number      Double             Thorium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Ti_ug/L_MS          Number      Double             Titanium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Tl_ug/L_MS          Number      Double             Thallium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Tm_ug/L_MS          Number      Double             Thulium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    U_ug/L_MS           Number      Double             Uranium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    V_ug/L_MS           Number      Double             Vanadium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    W_ug/L_MS           Number      Double             Tungsten, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Y_ug/L_MS           Number      Double             Yttrium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Yb_ug/L_MS          Number      Double             Ytterbium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Zn_ug/L_MS          Number      Double             Zinc, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    Zr_ug/L_MS          Number      Double             Zirconium, in micrograms per liter, by inductively coupled plasma-mass spectrometry.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table IndicatorMineralogy is a table of indicator mineralogy data for concentrates of till and stream sediment samples collected and analyzed for the Pebble project.
    FieldName              FieldType   FieldSize-Format   FieldDescript
    SampleID               Number      Long Integer       Unique sample identifier.
    SampleNumber           Text        20                 Sample number provided by submitter.
    FieldSiteNumber        Text        15                 Unique field site ID assigned by scientist in the field.
    JOB_ID                 Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD       Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD      Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName           Text        15                 Short name of laboratory that performed analysis.
    QA-QC                  Text        50                 Quality assurance and quality control information regarding sample.
    Au-vg_thick_calc       Number      Double             Thickness of visible gold grains, calculated, in microns.
    Au-vg_thick_msrd       Number      Double             Thickness of visible gold grains, measured, in microns.
    Au-vg_width            Number      Double             Width of visible gold grains, measured, in microns.
    Au-vg_length           Number      Double             Length of visible gold grains, measured, in microns.
    Au-vg_reshaped         Number      Double             Number of visible reshaped gold grains.
    Au-vg_modified         Number      Double             Number of visible modified gold grains.
    Au-vg_pristine         Number      Double             Number of visible pristine gold grains.
    Au-vg_total            Number      Double             Number of visible gold grains, reshaped + modified + pristine; total.
    Au-vg_reshaped_ppb     Number      Double             Gold in visible reshaped gold grains, calculated, in parts per billion.
    Au-vg_modified_ppb     Number      Double             Gold in visible modified gold grains, calculated, in parts per billion.
    Au-vg_pristine_ppb     Number      Double             Gold in visible pristine gold grains, calculated, in parts per billion.
    Au-vg_total_ppb        Number      Double             Gold in total visible gold grains, reshaped + modified + pristine; calculated, in parts per billion.
    VisGrainComment        Memo        65,535             Comment regarding mineralogy observed in visible grain sample.
    PC-wt_Total            Number      Double             Weight of field pan concentrate, total, in grams.
    PC-wt_Total_>vcsd      Number      Double             Weight of field pan concentrate, greater than 2.0 mm sieve grain size (greater than very coarse sand), in grams.
    PC-wt_Total_<fsd       Number      Double             Weight of field pan concentrate, less than 0.125 mm sieve grain size (less than fine sand), in grams.
    PC-wt_Total_f-vcsd     Number      Double             Weight of field pan concentrate, 0.125 to 2.00 mm sieve grain size (fine to very coarse sand), total, in grams.
    PC-wt_Light            Number      Double             Weight of field pan concentrate, 0.125 to 2.00 mm sieve grain size, specific gravity less than 2.8 after heavy liquid separation, "lights", in grams.
    PC-wt_HMC-mag          Number      Double             Weight of field pan concentrate, 0.125 to 2.00 mm sieve grain size, specific gravity less than 2.8 after heavy liquid separation, magnetic heavy mineral concentrate, in grams.
    PC-wt_NFM-mod_f-vcsd   Number      Double             Weight of field pan concentrate, 0.125 to 2.00 mm sieve grain size (fine to very coarse sand), SG 2.8 to 3.2 after heavy liquid separation, nonferromagnetic fraction, total, in
    
    grams.
    PC-wt_NFM-mod_<fsd     Number      Double             Weight of field pan concentrate, less than 0.125 mm sieve grain size (less than fine sand), washed, SG 2.8 to 3.2 after heavy liquid separation, nonferromagnetic fraction, in grams.
    PC-wt_NFM-mod_fsd      Number      Double             Weight of field pan concentrate, 0.125 to 0.25 mm sieve grain size (fine sand), SG 2.8 to 3.2 after heavy liquid separation, nonferromagnetic fraction, in grams.
    PC-wt_NFM-mod_msd      Number      Double             Weight of field pan concentrate, 0.25 to 0.5 mm sieve grain size (medium sand), SG 2.8 to 3.2 after heavy liquid separation, nonferromagnetic fraction, in grams.
    PC-wt_NFM-mod_csd      Number      Double             Weight of field pan concentrate, 0.5 to 1 mm sieve grain size (coarse sand), SG 2.8 to 3.2 after heavy liquid separation, nonferromagnetic fraction, in grams.
    PC-wt_NFM-mod_vcsd     Number      Double             Weight of field pan concentrate, 1 to 2 mm sieve grain size, (greater than very coarse sand), SG 2.8 to 3.2 after heavy liquid separation, nonferromagnetic fraction, in grams.
    PC-wt_NFM-hvy_f-vcsd   Number      Double             Weight of field pan concentrate, 0.125 to 2.00 mm sieve grain size (fine to very coarse sand), SG greater than 3.2 after heavy liquid separation, nonferromagnetic fraction, total, in
    
    grams.
    PC-wt_NFM-hvy_<fsd     Number      Double             Weight of field pan concentrate, less than 0.125 mm sieve grain size (less than fine sand), washed, SG greater than 3.2 after heavy liquid separation, nonferromagnetic fraction, in
    
    grams.
    PC-wt_NFM-hvy_msd      Number      Double             Weight of field pan concentrate, 0.25 to 0.5 mm sieve grain size (medium sand), SG greater than 3.2 after heavy liquid separation, nonferromagnetic fraction, in grams.
    PC-wt_NFM-hvy_csd      Number      Double             Weight of field pan concentrate, 0.5 to 1 mm sieve grain size (coarse sand), SG greater than 3.2 after heavy liquid separation, nonferromagnetic fraction, in grams.
    PC-wt_NFM-hvy_fsd      Number      Double             Weight of field pan concentrate, 0.125 to 0.25 mm sieve grain size (fine sand), SG greater than 3.2 after heavy liquid separation, nonferromagnetic fraction, in grams.
    PC-wt_NFM-hvy_vcsd     Number      Double             Weight of field pan concentrate, 1 to 2 mm sieve grain size, (greater than very coarse sand), SG greater than 3.2 after heavy liquid separation, nonferromagnetic fraction, in grams.
    Spl-wt_bulk            Number      Double             Sample weight, bulk received, in kilograms.
    Spl-wt_table-split     Number      Double             Sample weight, table split, in kilograms.
    Spl-wt_>vcsd           Number      Double             Sample weight, greater than 2 mm sieve particle size clasts (greater than very coarse sand), in kilograms.
    Spl-wt_table-feed      Number      Double             Sample weight, table feed, in kilograms.
    Clast_size             Text        10                 Largest clasts present, greater than 2.0 mm sieve particle size.
    Clast_V/S              Text        10                 Volcanics and/or sediment components of clasts, greater than 2.0 mm sieve particle size.
    Clast_GR               Text        10                 Granitic components of clasts, greater than 2.0 mm sieve particle size.
    Clast_LS               Text        10                 Limestone and/or carbonate components of clasts, greater than 2.0 mm sieve particle size.
    Clast_OT               Text        10                 Other lithology components of clasts, greater than 2.0 mm sieve particle size.
    Matrix_S/U             Text        10                 Sorting of matrix, less than 2.0 mm sieve particle size.
    Matrix_SD_distrib      Text        35                 Sand fraction in matrix, less than 2.0 mm sieve particle size.
    Matrix_ST              Text        35                 Silt fraction in matrix, less than 2.0 mm sieve particle size.
    Matrix_CY_distrib      Text        35                 Clay fraction in matrix, less than 2.0 mm sieve particle size.
    Matrix_org             Text        35                 Organic fraction in matrix, less than 2.0 mm sieve particle size.
    Matrix_SD_color        Text        25                 Color of sand in matrix, less than 2.0 mm sieve particle size.
    Matrix_CY_color        Text        25                 Color of clay in matrix, less than 2.0 mm sieve particle size.
    SedClass               Text        25                 Sediment class name.
    CPY                    Text        25                 Chalcopyrite, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, and magnetic susceptibility greater than 1 amp.
    PCIM_Sulf/As           Text        50                 Prime porphyry copper indicator minerals (or metamorphosed/magmatic massive sulfide indicator minerals), sulfide-arsenide and related minerals, in till fraction with specific gravity
    
    greater than 3.2, 0.25 to 0.5 mm sieve grain size, magnetic susceptibility greater than 1 amp.
    PY                     Text        25                 Pyrite, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, magnetic susceptibility greater than 1 amp.
    GTH                    Text        25                 Goethite, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, and magnetic susceptibility less than 1 amp.
    ADR                    Text        25                 Andradite, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, and magnetic susceptibility less than 1 amp.
    PCIM_Mg/Mn/Al/Cr/Ti    Text        100                Prime porphyry copper indicator minerals, magnesium/manganese/aluminum/chromium/titanium minerals, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain
    
    size, and magnetic susceptibility greater than 1 amp.
    MnOx                   Text        25                 Manganese oxide, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, and magnetic susceptibility greater than 1 amp.
    RUT                    Text        25                 Red rutile, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, magnetic susceptibility greater than 1 amp.
    TTN                    Text        25                 Blonde titanite, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, magnetic susceptibility greater than 1 amp.
    ASE                    Text        25                 Anatase, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, and magnetic susceptibility greater than 1 amp.
    SPI                    Text        25                 Spinel, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, magnetic susceptibility greater than 1 amp.
    KY/SIL                 Text        25                 Kyanite and/or sillimanite, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, and magnetic susceptibility greater than 1 amp.
    TM_>hvySG              Text        25                 Tourmaline, in till fraction with specific gravity greater than 3.2 (heavy), 0.25 to 0.5 mm sieve grain size, magnetic susceptibility greater than 1 amp.
    ST                     Text        25                 Staurolite, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, magnetic susceptibility greater than 1 amp.
    OL                     Text        25                 Olivine, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, and magnetic susceptibility less than 0.8 amp.
    OPX                    Text        25                 Orthopyroxene, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, and magnetic susceptibility less than 0.8 amp.
    CR                     Text        25                 Chromite, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, and magnetic susceptibility less than 0.8 amp.
    AP                     Text        25                 Apatite, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, and magnetic susceptibility greater than 1 amp.
    MZ                     Text        25                 Monazite, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, and magnetic susceptibility greater than 1 amp.
    ZR                     Text        25                 Rose zircon, in till fraction with specific gravity greater than 3.2, 0.25 to 0.5 mm sieve grain size, magnetic susceptibility greater than 1 amp.
    PCIM_>hvySG_remarks    Memo        65,535             Remarks regarding porphyry copper indicator minerals, in till fraction with specific gravity greater than 3.2 (heavy), and 0.25 to 0.5 mm sieve grain size.
    Assemblage             Text        75                 Mineral assemblage, porphyry copper indicator minerals, in till fraction with specific gravity greater than 3.2, and 0.25 to 0.5 mm sieve grain size.
    Cu-mnrls               Text        25                 Copper minerals, in till fraction with specific gravity 2.8 to 3.2, 0.25 to 0.5 mm sieve grain size.
    PCIM_misc              Text        50                 Miscellaneous prime porphyry copper indicator minerals, in till fraction with specific gravity 2.8 to 3.2, 0.25 to 0.5 mm sieve grain size.
    JAR                    Text        25                 Jarosite, in till fraction with specific gravity 2.8 to 3.2, and 0.25 to 0.5 mm sieve grain size.
    ALN                    Text        25                 Alunite, in till fraction with specific gravity 2.8 to 3.2, and 0.25 to 0.5 mm sieve grain size.
    TM_medSG               Text        25                 Tourmaline in till fraction with specific gravity 2.8 to 3.2 (medium), 0.25 to 0.5 mm sieve grain size.
    PCIM_medSG_remarks     Memo        65,535             Remarks regarding porphyry copper indicator minerals, in till fraction with specific gravity 2.8 to 3.2 (medium), and 0.25 to 0.5 mm sieve grain size.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table LabName is a table of laboratories providing analytic data for the Pebble project.
    FieldName      FieldType   FieldSize-Format   FieldDescript
    
    LabShortName   Text        15                 Short name of laboratory that performed analysis.
    LabName        Text        255                Long name of laboratory that performed analysis.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Parameter is a table of parameters used to describe chemical and physical data yielded from samples collected and analyzed for the Pebble project.
    FieldName         FieldType   FieldSize-Format   FieldDescript
    
    ParameterCode     Text        25                 Species and unit of measurement.
    ParameterName     Text        125                255-character field describing specific result.
    ConstituentName   Text        50                 Element name or similar chemical group.
    ReportUnits       Text        10                 Units of measurement.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table QualResult is a table of qualitative chemical and physical data yielded from samples collected and analyzed for the Pebble project.
    FieldName                 FieldType    FieldSize-Format   FieldDescript
    
    QualResultID              AutoNumber   Long Integer       Unique qualitative value identifier.
    SampleID                  Number       Long Integer       Unique sample identifier.
    QualValue                 Text         50                 Qualitative result.
    ParameterCode             Text         25                 Species and unit of measurement.
    AnalyticMethodShortName   Text         15                 Short name of analytic method.
    LabShortName              Text         15                 Short name of laboratory that performed analysis.
    SampleAnalyzed            Text         100                Description of actual sample analyzed.
    QualValueComment          Text         75                 Miscellaneous comments about result.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table QuantResult is a table of quantitative chemical and physical data yielded from samples collected and analyzed for the Pebble project.
    FieldName                 FieldType    FieldSize-Format   FieldDescript
    
    QuantResultID             AutoNumber   Long Integer       Unique quantitative value identifier.
    SampleID                  Number       Long Integer       Unique sample identifier.
    QuantValue                Number       Double             Numeric result.
    QuantValueQual            Text         1                  Modifer for result; i.e., '<', '>'.
    QualifiedValue            Number       Double             Numeric result; qualified so that QuantValues with associated QuantValueQuals '<', 'N' or 'L' are expressed as negative values, and QuantValues with associated QuantValueQuals '>' or 'G' end in '111'.
    Parameter                 Text         35                 Chemical parameter that is a concatenation of ParameterCode, and AnalyticMethodShortName.
    ParameterCode             Text         25                 Species and unit of measurement.
    AnalyticMethodShortName   Text         15                 Short name of analytic method.
    LabShortName              Text         15                 Short name of laboratory that performed analysis.
    SampleAnalyzed            Text         100                Description of actual sample analyzed.
    AnalOrder                 Text         Long Integer       Initial order in which sample was run in job.
    QuantValueComment         Text         75                 Miscellaneous comments about result.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Rock_AddlChem is a table of chemical data from non-ICP analytic methods for rock samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Au_ppm_FA           Number      Double             Gold, in parts per million, by fire assay and direct current plasma-atomic emission spectroscopy.
    C_pct_Comb          Number      Double             Total carbon, in weight percent, by infrared detection after combustion at 1370å¡C in an automated carbon analyzer.
    CO2_pct_Titr        Number      Double             Carbon dioxide, in weight percent, by coulometric titration.
    C-CO3_pct_Titr      Number      Double             Carbonate carbon, in weight percent, by coulometric titration and computation (CO2/3.664).
    C-Org_pct_Comb      Number      Double             Organic carbon, in weight percent, by the calculated difference between total carbon and carbonate carbon.
    Cl_ppm_ISE          Number      Double             Chlorine, in parts per million, by ion specific electrode.
    F_ppm_ISE           Number      Double             Fluorine, in parts per million, by ion specific electrode.
    Hg_ppm_AA           Number      Double             Mercury, in parts per million, by cold vapor atomic absorption spectroscopy.
    Sb_ppm_AA           Number      Double             Antimony, in parts per million, by hydride generation atomic absorption spectroscopy.
    Se_ppm_AA           Number      Double             Selenium, in parts per million, by hydride generation atomic absorption spectroscopy.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Rock_ICPAES-MS42 is a table of inductively coupled plasma-atomic emission/mass spectroscopy chemical data after acid digestion for rock samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppm_AES-MS42     Number      Double             Silver, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Al_pct_AES-MS42     Number      Double             Aluminum, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    As_ppm_AES-MS42     Number      Double             Arsenic, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ba_ppm_AES-MS42     Number      Double             Barium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Be_ppm_AES-MS42     Number      Double             Beryllium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Bi_ppm_AES-MS42     Number      Double             Bismuth, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ca_pct_AES-MS42     Number      Double             Calcium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Cd_ppm_AES-MS42     Number      Double             Cadmium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ce_ppm_AES-MS42     Number      Double             Cerium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Co_ppm_AES-MS42     Number      Double             Cobalt, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Cr_ppm_AES-MS42     Number      Double             Chromium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Cs_ppm_AES-MS42     Number      Double             Cesium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Cu_ppm_AES-MS42     Number      Double             Copper, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Fe_pct_AES-MS42     Number      Double             Iron, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ga_ppm_AES-MS42     Number      Double             Gallium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    In_ppm_AES-MS42     Number      Double             Indium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    K_pct_AES-MS42      Number      Double             Potassium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    La_ppm_AES-MS42     Number      Double             Lanthanum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Li_ppm_AES-MS42     Number      Double             Lithium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Mg_pct_AES-MS42     Number      Double             Magnesium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Mn_ppm_AES-MS42     Number      Double             Manganese, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Mo_ppm_AES-MS42     Number      Double             Molybdenum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Na_pct_AES-MS42     Number      Double             Sodium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Nb_ppm_AES-MS42     Number      Double             Niobium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ni_ppm_AES-MS42     Number      Double             Nickel, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    P_pct_AES-MS42      Number      Double             Phosphorus, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Pb_ppm_AES-MS42     Number      Double             Lead, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Rb_ppm_AES-MS42     Number      Double             Rubidium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    S_pct_AES-MS42      Number      Double             Sulfur, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Sb_ppm_AES-MS42     Number      Double             Antimony, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Sc_ppm_AES-MS42     Number      Double             Scandium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Sn_ppm_AES-MS42     Number      Double             Tin, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Sr_ppm_AES-MS42     Number      Double             Strontium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Te_ppm_AES-MS42     Number      Double             Tellurium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Th_ppm_AES-MS42     Number      Double             Thorium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ti_pct_AES-MS42     Number      Double             Titanium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Tl_ppm_AES-MS42     Number      Double             Thallium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    U_ppm_AES-MS42      Number      Double             Uranium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    V_ppm_AES-MS42      Number      Double             Vanadium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    W_ppm_AES-MS42      Number      Double             Tungsten, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Y_ppm_AES-MS42      Number      Double             Yttrium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Zn_ppm_AES-MS42     Number      Double             Zinc, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Rock_ICPAES-MS55 is a table of inductively coupled plasma-atomic emission/mass spectroscopy chemical data after sinter digestion for rock samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSite           Number      Text               15   Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppm_AES-MS55     Number      Double             Silver, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Al_pct_AES-MS55     Number      Double             Aluminum, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    As_ppm_AES-MS55     Number      Double             Arsenic, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ba_ppm_AES-MS55     Number      Double             Barium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Be_ppm_AES-MS55     Number      Double             Beryllium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Bi_ppm_AES-MS55     Number      Double             Bismuth, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ca_pct_AES-MS55     Number      Double             Calcium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Cd_ppm_AES-MS55     Number      Double             Cadmium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ce_ppm_AES-MS55     Number      Double             Cerium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Co_ppm_AES-MS55     Number      Double             Cobalt, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Cr_ppm_AES-MS55     Number      Double             Chromium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Cs_ppm_AES-MS55     Number      Double             Cesium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Cu_ppm_AES-MS55     Number      Double             Copper, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Dy_ppm_AES-MS55     Number      Double             Dysprosium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Er_ppm_AES-MS55     Number      Double             Erbium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Eu_ppm_AES-MS55     Number      Double             Europium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Fe_pct_AES-MS55     Number      Double             Iron, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ga_ppm_AES-MS55     Number      Double             Gallium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Gd_ppm_AES-MS55     Number      Double             Gadolinium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ge_ppm_AES-MS55     Number      Double             Germanium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Hf_ppm_AES-MS55     Number      Double             Hafnium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ho_ppm_AES-MS55     Number      Double             Holmium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    In_ppm_AES-MS55     Number      Double             Indium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    K_pct_AES-MS55      Number      Double             Potassium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    La_ppm_AES-MS55     Number      Double             Lanthanum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Li_ppm_AES-MS55     Number      Double             Lithium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Lu_ppm_AES-MS55     Number      Double             Lutetium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Mg_pct_AES-MS55     Number      Double             Magnesium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Mn_ppm_AES-MS55     Number      Double             Manganese, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Mo_ppm_AES-MS55     Number      Double             Molybdenum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Nb_ppm_AES-MS55     Number      Double             Niobium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Nd_ppm_AES-MS55     Number      Double             Neodymium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ni_ppm_AES-MS55     Number      Double             Nickel, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    P_pct_AES-MS55      Number      Double             Phosphorus, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Pb_ppm_AES-MS55     Number      Double             Lead, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Pr_ppm_AES-MS55     Number      Double             Praseodymium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Rb_ppm_AES-MS55     Number      Double             Rubidium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sb_ppm_AES-MS55     Number      Double             Antimony, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sc_ppm_AES-MS55     Number      Double             Scandium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sm_ppm_AES-MS55     Number      Double             Samarium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sn_ppm_AES-MS55     Number      Double             Tin, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sr_ppm_AES-MS55     Number      Double             Strontium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ta_ppm_AES-MS55     Number      Double             Tantalum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Tb_ppm_AES-MS55     Number      Double             Terbium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Th_ppm_AES-MS55     Number      Double             Thorium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ti_pct_AES-MS55     Number      Double             Titanium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Tl_ppm_AES-MS55     Number      Double             Thallium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Tm_ppm_AES-MS55     Number      Double             Thulium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    U_ppm_AES-MS55      Number      Double             Uranium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    V_ppm_AES-MS55      Number      Double             Vanadium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    W_ppm_AES-MS55      Number      Double             Tungsten, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Y_ppm_AES-MS55      Number      Double             Yttrium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Yb_ppm_AES-MS55     Number      Double             Ytterbium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion
    Zn_ppm_AES-MS55     Number      Double             Zinc, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Zr_ppm_AES-MS55     Number      Double             Zirconium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Sample is a table of descriptive attributes for samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    IncrementsPerArea   Text        15                 Number of sub-sample increments : area sampled in square feet, for composite sample.
    SampleDate          Date/Time   Short Date         Day sample was taken, in mmddyyyy.
    SampleTime          Date/Time   Short Time         Time sample was taken, in military time.
    SampleMediaGross    Text        15                 General type of sample media.
    SampleMediaDetail   Text        75                 Detail type of sample media.
    SampleDesc          Memo        65,535             Further description of sample.
    OrganicContent      Text        50                 Relative organic content in sample collected.
    SpeciesGenus        Text        15                 Species and genus names for plant or animal samples.
    CommonName          Text        25                 Common name for sampled vegetation.
    CollectionMethod    Text        50                 Method used to collect sample, i.e. grab, composite, etc.
    SampleSource        Text        175                Source of sample.
    SampleZone          Text        15                 Soil horizon sampled
    SampleIntent        Text        50                 Intent of sample: GX, geochemistry; HS, hand sample; XRD, x-ray mineral identification; leach, water leach test; MIN, binocular mineralogy, etc.
    FieldSamplePrep     Text        200                Preparation of sample in field prior to submittal to lab for analysis.
    LabSamplePrep       Text        255                Preparation of sample done in the laboratory prior to analysis.
    SieveSize           Text        15                 Sieve size used in laboratory preparation; given in both mesh size and millimeter opening size.
    CollectorCode       Text        25                 Last name and first name initial of the scientist who collected the sample and the year the sample was collected.
    SampleCom           Text        255                Any additional note not captured elsewhere regarding the sample.
    FieldMnrlgy         Text        255                Minerals identified by handlens in the field.
    BinocMnrlgy         Text        255                Minerals identified in the lab with binocular microscope.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table SampleID_H2O is a table joining Sample table to derivative water media data tables of the Pebble project.
    FieldName   FieldType   FieldSize-Format   FieldDescript
    
    SampleID    Number      Long Integer       Unique sample identifier.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table SampleID_Soil is a table joining Sample table to derivative soil media data tables of the Pebble project.
    FieldName FieldType FieldSize-Format FieldDescript
    
    
    SampleID Number Long Integer Unique sample identifier.
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Sed_AddlChem is a table of chemical data from non-ICP analytic methods for sediment samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleSource        Text        175                Source of sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    As_ppm_AA           Number      Double             Arsenic, in parts per million, by hydride generation atomic absorption spectrophotometry.
    Au_ppm_FA           Number      Double             Gold, in parts per million, by fire assay and direct current plasma-atomic emission spectroscopy.
    C_pct_Comb          Number      Double             Total carbon, in weight percent, by infrared detection after combustion at 1370å¡C in an automated carbon analyzer.
    CO2_pct_Titr        Number      Double             Carbon dioxide, in weight percent, by coulometric titration.
    C-CO3_pct_Titr      Number      Double             Carbonate carbon, in weight percent, by coulometric titration and computation (CO2/3.664).
    C-Org_pct_Comb      Number      Double             Organic carbon, in weight percent, by the calculated difference between total carbon and carbonate carbon.
    Cl_ppm_ISE          Number      Double             Chlorine, in parts per million, by ion specific electrode.
    F_ppm_ISE           Number      Double             Fluorine, in parts per million, by ion specific electrode.
    Hg_ppm_AA           Number      Double             Mercury, in parts per million, by cold vapor atomic absorption spectroscopy.
    Sb_ppm_AA           Number      Double             Antimony, in parts per million, by hydride generation atomic absorption spectroscopy.
    Se_ppm_AA           Number      Double             Selenium, in parts per million, by hydride generation atomic absorption spectroscopy.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Sed_ICPAES-MS42 is a table of inductively coupled plasma-atomic emission/mass spectroscopy chemical data after acid digestion for sediment samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleSource        Text        175                Source of sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppm_AES-MS42     Number      Double             Silver, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Al_pct_AES-MS42     Number      Double             Aluminum, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    As_ppm_AES-MS42     Number      Double             Arsenic, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ba_ppm_AES-MS42     Number      Double             Barium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Be_ppm_AES-MS42     Number      Double             Beryllium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Bi_ppm_AES-MS42     Number      Double             Bismuth, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ca_pct_AES-MS42     Number      Double             Calcium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Cd_ppm_AES-MS42     Number      Double             Cadmium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ce_ppm_AES-MS42     Number      Double             Cerium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Co_ppm_AES-MS42     Number      Double             Cobalt, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Cr_ppm_AES-MS42     Number      Double             Chromium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Cs_ppm_AES-MS42     Number      Double             Cesium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Cu_ppm_AES-MS42     Number      Double             Copper, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Fe_pct_AES-MS42     Number      Double             Iron, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ga_ppm_AES-MS42     Number      Double             Gallium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    In_ppm_AES-MS42     Number      Double             Indium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    K_pct_AES-MS42      Number      Double             Potassium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    La_ppm_AES-MS42     Number      Double             Lanthanum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Li_ppm_AES-MS42     Number      Double             Lithium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Mg_pct_AES-MS42     Number      Double             Magnesium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Mn_ppm_AES-MS42     Number      Double             Manganese, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Mo_ppm_AES-MS42     Number      Double             Molybdenum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Na_pct_AES-MS42     Number      Double             Sodium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Nb_ppm_AES-MS42     Number      Double             Niobium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ni_ppm_AES-MS42     Number      Double             Nickel, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    P_pct_AES-MS42      Number      Double             Phosphorus, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Pb_ppm_AES-MS42     Number      Double             Lead, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Rb_ppm_AES-MS42     Number      Double             Rubidium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    S_pct_AES-MS42      Number      Double             Sulfur, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Sb_ppm_AES-MS42     Number      Double             Antimony, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Sc_ppm_AES-MS42     Number      Double             Scandium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Sn_ppm_AES-MS42     Number      Double             Tin, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Sr_ppm_AES-MS42     Number      Double             Strontium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Te_ppm_AES-MS42     Number      Double             Tellurium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Th_ppm_AES-MS42     Number      Double             Thorium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ti_pct_AES-MS42     Number      Double             Titanium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Tl_ppm_AES-MS42     Number      Double             Thallium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    U_ppm_AES-MS42      Number      Double             Uranium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    V_ppm_AES-MS42      Number      Double             Vanadium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    W_ppm_AES-MS42      Number      Double             Tungsten, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Y_ppm_AES-MS42      Number      Double             Yttrium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Zn_ppm_AES-MS42     Number      Double             Zinc, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Sed_ICPAES-MS55 is a table of inductively coupled plasma-atomic emission/mass spectroscopy chemical data after sinter digestion for sediment samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleSource        Text        175                Source of sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppm_AES-MS55     Number      Double             Silver, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Al_pct_AES-MS55     Number      Double             Aluminum, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    As_ppm_AES-MS55     Number      Double             Arsenic, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ba_ppm_AES-MS55     Number      Double             Barium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Be_ppm_AES-MS55     Number      Double             Beryllium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Bi_ppm_AES-MS55     Number      Double             Bismuth, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ca_pct_AES-MS55     Number      Double             Calcium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Cd_ppm_AES-MS55     Number      Double             Cadmium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ce_ppm_AES-MS55     Number      Double             Cerium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Co_ppm_AES-MS55     Number      Double             Cobalt, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Cr_ppm_AES-MS55     Number      Double             Chromium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Cs_ppm_AES-MS55     Number      Double             Cesium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Cu_ppm_AES-MS55     Number      Double             Copper, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Dy_ppm_AES-MS55     Number      Double             Dysprosium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Er_ppm_AES-MS55     Number      Double             Erbium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Eu_ppm_AES-MS55     Number      Double             Europium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Fe_pct_AES-MS55     Number      Double             Iron, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ga_ppm_AES-MS55     Number      Double             Gallium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Gd_ppm_AES-MS55     Number      Double             Gadolinium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ge_ppm_AES-MS55     Number      Double             Germanium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Hf_ppm_AES-MS55     Number      Double             Hafnium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ho_ppm_AES-MS55     Number      Double             Holmium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    In_ppm_AES-MS55     Number      Double             Indium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    K_pct_AES-MS55      Number      Double             Potassium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    La_ppm_AES-MS55     Number      Double             Lanthanum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Li_ppm_AES-MS55     Number      Double             Lithium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Lu_ppm_AES-MS55     Number      Double             Lutetium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Mg_pct_AES-MS55     Number      Double             Magnesium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Mn_ppm_AES-MS55     Number      Double             Manganese, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Mo_ppm_AES-MS55     Number      Double             Molybdenum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Nb_ppm_AES-MS55     Number      Double             Niobium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Nd_ppm_AES-MS55     Number      Double             Neodymium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ni_ppm_AES-MS55     Number      Double             Nickel, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    P_pct_AES-MS55      Number      Double             Phosphorus, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Pb_ppm_AES-MS55     Number      Double             Lead, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Pr_ppm_AES-MS55     Number      Double             Praseodymium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Rb_ppm_AES-MS55     Number      Double             Rubidium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sb_ppm_AES-MS55     Number      Double             Antimony, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sc_ppm_AES-MS55     Number      Double             Scandium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sm_ppm_AES-MS55     Number      Double             Samarium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sn_ppm_AES-MS55     Number      Double             Tin, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sr_ppm_AES-MS55     Number      Double             Strontium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ta_ppm_AES-MS55     Number      Double             Tantalum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Tb_ppm_AES-MS55     Number      Double             Terbium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Th_ppm_AES-MS55     Number      Double             Thorium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ti_pct_AES-MS55     Number      Double             Titanium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Tl_ppm_AES-MS55     Number      Double             Thallium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Tm_ppm_AES-MS55     Number      Double             Thulium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    U_ppm_AES-MS55      Number      Double             Uranium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    V_ppm_AES-MS55      Number      Double             Vanadium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    W_ppm_AES-MS55      Number      Double             Tungsten, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Y_ppm_AES-MS55      Number      Double             Yttrium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Yb_ppm_AES-MS55     Number      Double             Ytterbium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion
    Zn_ppm_AES-MS55     Number      Double             Zinc, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Zr_ppm_AES-MS55     Number      Double             Zirconium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_AddlChem is a table of chemical data from non-ICP analytic methods for soil samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    As_ppm_AA           Number      Double             Arsenic, in parts per million, by hydride generation atomic absorption spectrophotometry.
    Au_ppm_FA           Number      Double             Gold, in parts per million, by fire assay and direct current plasma-atomic emission spectroscopy.
    C_pct_Comb          Number      Double             Total carbon, in weight percent, by infrared detection after combustion at 1370å¡C in an automated carbon analyzer.
    CO2_pct_Titr        Number      Double             Carbon dioxide, in weight percent, by coulometric titration.
    C-CO3_pct_Titr      Number      Double             Carbonate carbon, in weight percent, by coulometric titration and computation (CO2/3.664).
    C-Org_pct_Comb      Number      Double             Organic carbon, in weight percent, by the calculated difference between total carbon and carbonate carbon.
    Cl_ppm_ISE          Number      Double             Chlorine, in parts per million, by ion specific electrode.
    F_ppm_ISE           Number      Double             Fluorine, in parts per million, by ion specific electrode.
    Hg_ppm_AA           Number      Double             Mercury, in parts per million, by cold vapor atomic absorption spectroscopy.
    Sb_ppm_AA           Number      Double             Antimony, in parts per million, by hydride generation atomic absorption spectroscopy.
    Se_ppm_AA           Number      Double             Selenium, in parts per million, by hydride generation atomic absorption spectroscopy.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_GCMS-SGH is a table of gas chromatography/mass spectroscopy weak leach simulation chemical data from soil samples collected and analyzed for the Pebble project.
    FieldName             FieldType   FieldSize-Format   FieldDescript
    
    SampleID              Number      Long Integer       Unique sample identifier.
    SampleNumber          Text        20                 Sample number provided by submitter.
    FieldSiteNumber       Text        15                 Unique field site ID assigned by scientist in the field.
    JOB_ID                Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD      Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD     Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName          Text        15                 Short name of laboratory that performed analysis.
    QA-QC                 Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed        Text        100                Description of actual sample analyzed.
    SGH001LA_ppt_GC-MS    Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH002LA_ppt_GC-MS    Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH003LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH004LA_ppt_GC-MS    Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH005LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH006LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH007LA_ppt_GC-MS    Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH008LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH009LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH010LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH011LA_ppt_GC-MS    Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH012LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH013LBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH014LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH015LAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH016LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH017LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH018LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH019LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH020LA_ppt_GC-MS    Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH021LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH022LBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH023LAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH024LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH025LAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH026LBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH027LB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH028ALK_ppt_GC-MS   Number      Double             alkyl-alkene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH029HB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH030HB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH031HB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH032HB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH033HB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH034HB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH035LAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH036LBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH037HB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH038LBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH039LAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH040LPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH041LBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH042LPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH043HB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH044HB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH045LA_ppt_GC-MS    Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH046LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH047LBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH048HB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH049HB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH050LBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH051LBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH052LPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH053LPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH054HB_ppt_GC-MS    Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH055LPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH056LBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH057ALK_ppt_GC-MS   Number      Double             alkyl-alkene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH058LPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH059LPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH060LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH061LBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH062LBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH063LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH064LBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH065HPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH066LBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH067LBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH068HPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH069LA_ppt_GC-MS    Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH070HPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH071HPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH072HPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH073HBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH074HBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH075HPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH076LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH077MAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH078ALK_ppt_GC-MS   Number      Double             alkyl-alkene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH079LBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH080LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH081MAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH082LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH083HBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH084HBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH085LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH086LBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH087MAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH088HBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH089THI_ppt_GC-MS   Number      Double             alkyl-divinylene sulfide compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH090HPB_ppt_GC-MS   Number      Double             alkyl-benzene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH091LBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH092LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH093LA_ppt_GC-MS    Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH094LBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH095MAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH096LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH097HBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH098THI_ppt_GC-MS   Number      Double             alkyl-divinylene sulfide compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH099LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH100LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH101MAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH102MBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH103LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH104MAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH105ALK_ppt_GC-MS   Number      Double             alkyl-alkene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH106MBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH107MBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH108LPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH109MAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH110HBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH111MAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH112MBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH113HBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH114MBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH115MBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH116MAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH117HA_ppt_GC-MS    Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH118MPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH119HBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH120THI_ppt_GC-MS   Number      Double             alkyl-divinylene sulfide compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH121MPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH122MPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH123MPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH124MBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH125HAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH126MPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH127MPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH128MPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH129HAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH130HAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH131MPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH132ALK_ppt_GC-MS   Number      Double             alkyl-alkene compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH133HAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH134HAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH135MPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH136MPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH137HBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH138HBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH139HPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH140HPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH141HBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH142HPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH143HA_ppt_GC-MS    Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH144HBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH145HBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH146HPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH147HBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH148HPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH149HBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH150HPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH151HBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH152HPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH153HPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH154HPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH155HPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH156HBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH157HAR_ppt_GC-MS   Number      Double             alkyl-aromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH158HBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH159HBA_ppt_GC-MS   Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH160HBI_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH161HA_ppt_GC-MS    Number      Double             alkyl-alkane compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    SGH162HPH_ppt_GC-MS   Number      Double             alkyl-polyaromatic compounds, specifics are proprietary, in parts per trillion, by gas chromatography-mass spectroscopy after weak leach.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_ICPAES-MS42 is a table of inductively coupled plasma-atomic emission/mass spectroscopy chemical data after acid digestion for soil samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppm_AES-MS42     Number      Double             Silver, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Al_pct_AES-MS42     Number      Double             Aluminum, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    As_ppm_AES-MS42     Number      Double             Arsenic, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ba_ppm_AES-MS42     Number      Double             Barium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Be_ppm_AES-MS42     Number      Double             Beryllium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Bi_ppm_AES-MS42     Number      Double             Bismuth, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ca_pct_AES-MS42     Number      Double             Calcium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Cd_ppm_AES-MS42     Number      Double             Cadmium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ce_ppm_AES-MS42     Number      Double             Cerium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Co_ppm_AES-MS42     Number      Double             Cobalt, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Cr_ppm_AES-MS42     Number      Double             Chromium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Cs_ppm_AES-MS42     Number      Double             Cesium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Cu_ppm_AES-MS42     Number      Double             Copper, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Fe_pct_AES-MS42     Number      Double             Iron, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ga_ppm_AES-MS42     Number      Double             Gallium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    In_ppm_AES-MS42     Number      Double             Indium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    K_pct_AES-MS42      Number      Double             Potassium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    La_ppm_AES-MS42     Number      Double             Lanthanum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Li_ppm_AES-MS42     Number      Double             Lithium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Mg_pct_AES-MS42     Number      Double             Magnesium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Mn_ppm_AES-MS42     Number      Double             Manganese, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Mo_ppm_AES-MS42     Number      Double             Molybdenum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Na_pct_AES-MS42     Number      Double             Sodium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Nb_ppm_AES-MS42     Number      Double             Niobium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ni_ppm_AES-MS42     Number      Double             Nickel, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    P_pct_AES-MS42      Number      Double             Phosphorus, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Pb_ppm_AES-MS42     Number      Double             Lead, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Rb_ppm_AES-MS42     Number      Double             Rubidium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    S_pct_AES-MS42      Number      Double             Sulfur, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Sb_ppm_AES-MS42     Number      Double             Antimony, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Sc_ppm_AES-MS42     Number      Double             Scandium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Sn_ppm_AES-MS42     Number      Double             Tin, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Sr_ppm_AES-MS42     Number      Double             Strontium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Te_ppm_AES-MS42     Number      Double             Tellurium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Th_ppm_AES-MS42     Number      Double             Thorium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Ti_pct_AES-MS42     Number      Double             Titanium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Tl_ppm_AES-MS42     Number      Double             Thallium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    U_ppm_AES-MS42      Number      Double             Uranium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    V_ppm_AES-MS42      Number      Double             Vanadium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    W_ppm_AES-MS42      Number      Double             Tungsten, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Y_ppm_AES-MS42      Number      Double             Yttrium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    Zn_ppm_AES-MS42     Number      Double             Zinc, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after 4-acid digestion.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_ICPAES-MS55 is a table of inductively coupled plasma-atomic emission/mass spectroscopy chemical data after sinter digestion for soil samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppm_AES-MS55     Number      Double             Silver, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Al_pct_AES-MS55     Number      Double             Aluminum, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    As_ppm_AES-MS55     Number      Double             Arsenic, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ba_ppm_AES-MS55     Number      Double             Barium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Be_ppm_AES-MS55     Number      Double             Beryllium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Bi_ppm_AES-MS55     Number      Double             Bismuth, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ca_pct_AES-MS55     Number      Double             Calcium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Cd_ppm_AES-MS55     Number      Double             Cadmium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ce_ppm_AES-MS55     Number      Double             Cerium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Co_ppm_AES-MS55     Number      Double             Cobalt, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Cr_ppm_AES-MS55     Number      Double             Chromium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Cs_ppm_AES-MS55     Number      Double             Cesium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Cu_ppm_AES-MS55     Number      Double             Copper, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Dy_ppm_AES-MS55     Number      Double             Dysprosium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Er_ppm_AES-MS55     Number      Double             Erbium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Eu_ppm_AES-MS55     Number      Double             Europium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Fe_pct_AES-MS55     Number      Double             Iron, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ga_ppm_AES-MS55     Number      Double             Gallium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Gd_ppm_AES-MS55     Number      Double             Gadolinium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ge_ppm_AES-MS55     Number      Double             Germanium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Hf_ppm_AES-MS55     Number      Double             Hafnium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ho_ppm_AES-MS55     Number      Double             Holmium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    In_ppm_AES-MS55     Number      Double             Indium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    K_pct_AES-MS55      Number      Double             Potassium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    La_ppm_AES-MS55     Number      Double             Lanthanum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Li_ppm_AES-MS55     Number      Double             Lithium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Lu_ppm_AES-MS55     Number      Double             Lutetium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Mg_pct_AES-MS55     Number      Double             Magnesium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Mn_ppm_AES-MS55     Number      Double             Manganese, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Mo_ppm_AES-MS55     Number      Double             Molybdenum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Nb_ppm_AES-MS55     Number      Double             Niobium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Nd_ppm_AES-MS55     Number      Double             Neodymium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ni_ppm_AES-MS55     Number      Double             Nickel, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    P_pct_AES-MS55      Number      Double             Phosphorus, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Pb_ppm_AES-MS55     Number      Double             Lead, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Pr_ppm_AES-MS55     Number      Double             Praseodymium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Rb_ppm_AES-MS55     Number      Double             Rubidium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sb_ppm_AES-MS55     Number      Double             Antimony, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sc_ppm_AES-MS55     Number      Double             Scandium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sm_ppm_AES-MS55     Number      Double             Samarium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sn_ppm_AES-MS55     Number      Double             Tin, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Sr_ppm_AES-MS55     Number      Double             Strontium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ta_ppm_AES-MS55     Number      Double             Tantalum, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Tb_ppm_AES-MS55     Number      Double             Terbium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Th_ppm_AES-MS55     Number      Double             Thorium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Ti_pct_AES-MS55     Number      Double             Titanium, in weight percent, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Tl_ppm_AES-MS55     Number      Double             Thallium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Tm_ppm_AES-MS55     Number      Double             Thulium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    U_ppm_AES-MS55      Number      Double             Uranium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    V_ppm_AES-MS55      Number      Double             Vanadium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    W_ppm_AES-MS55      Number      Double             Tungsten, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Y_ppm_AES-MS55      Number      Double             Yttrium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Yb_ppm_AES-MS55     Number      Double             Ytterbium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion
    Zn_ppm_AES-MS55     Number      Double             Zinc, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    Zr_ppm_AES-MS55     Number      Double             Zirconium, in parts per million, by inductively coupled plasma-atomic emission spectroscopy or mass spectroscopy after sinter digestion.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_ICPMS-AR is a table of inductively coupled plasma-mass spectroscopy aqua regia leach chemical data from soil samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppm_MS-AR        Number      Double             Silver, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Al_pct_MS-AR        Number      Double             Aluminum, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    As_ppm_MS-AR        Number      Double             Arsenic, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Au_ppb_MS-AR        Number      Double             Gold, in parts per billion, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    B_ppm_MS-AR         Number      Double             Boron, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ba_ppm_MS-AR        Number      Double             Barium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Be_ppm_MS-AR        Number      Double             Beryllium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Bi_ppm_MS-AR        Number      Double             Bismuth, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ca_pct_MS-AR        Number      Double             Calcium, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Cd_ppm_MS-AR        Number      Double             Cadmium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ce_ppm_MS-AR        Number      Double             Cerium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Co_ppm_MS-AR        Number      Double             Cobalt, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Cr_ppm_MS-AR        Number      Double             Chromium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Cs_ppm_MS-AR        Number      Double             Cesium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Cu_ppm_MS-AR        Number      Double             Copper, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Fe_pct_MS-AR        Number      Double             Iron, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ga_ppm_MS-AR        Number      Double             Gallium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ge_ppm_MS-AR        Number      Double             Germanium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Hf_ppm_MS-AR        Number      Double             Hafnium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Hg_ppm_MS-AR        Number      Double             Mercury, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    In_ppm_MS-AR        Number      Double             Indium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    K_pct_MS-AR         Number      Double             Potassium, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    La_ppm_MS-AR        Number      Double             Lanthanum, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Li_ppm_MS-AR        Number      Double             Lithium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Mg_pct_MS-AR        Number      Double             Magnesium, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Mn_ppm_MS-AR        Number      Double             Manganese, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Mo_ppm_MS-AR        Number      Double             Molybdenum, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Na_pct_MS-AR        Number      Double             Sodium, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Nb_ppm_MS-AR        Number      Double             Niobium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ni_ppm_MS-AR        Number      Double             Nickel, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    P_pct_MS-AR         Number      Double             Phosphorus, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Pb_ppm_MS-AR        Number      Double             Lead, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Pd_ppb_MS-AR        Number      Double             Palladium, in parts per billion, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Pt_ppb_MS-AR        Number      Double             Platinum, in parts per billion, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Rb_ppm_MS-AR        Number      Double             Rubidium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Re_ppb_MS-AR        Number      Double             Rhenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    S_pct_MS-AR         Number      Double             Sulfur, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sb_ppm_MS-AR        Number      Double             Antimony, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sc_ppm_MS-AR        Number      Double             Scandium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Se_ppm_MS-AR        Number      Double             Selenium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sn_ppm_MS-AR        Number      Double             Tin, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sr_ppm_MS-AR        Number      Double             Strontium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ta_ppm_MS-AR        Number      Double             Tantalum, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Te_ppm_MS-AR        Number      Double             Tellurium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Th_ppm_MS-AR        Number      Double             Thorium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ti_pct_MS-AR        Number      Double             Titanium, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Tl_ppm_MS-AR        Number      Double             Thallium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    U_ppm_MS-AR         Number      Double             Uranium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    V_ppm_MS-AR         Number      Double             Vanadium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    W_ppm_MS-AR         Number      Double             Tungsten, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Y_ppm_MS-AR         Number      Double             Yttrium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Zn_ppm_MS-AR        Number      Double             Zinc, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Zr_ppm_MS-AR        Number      Double             Zirconium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_ICPMS-BLch is a table of inductively coupled plasma-mass spectroscopy BioLeach chemical data from soil samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppb_MS-BL        Number      Double             Silver, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    As_ppb_MS-BL        Number      Double             Arsenic, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Au_ppb_MS-BL        Number      Double             Gold, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Ba_ppb_MS-BL        Number      Double             Barium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Be_ppb_MS-BL        Number      Double             Beryllium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Bi_ppb_MS-BL        Number      Double             Bismuth, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Br_ppb_MS-BL        Number      Double             Bromine, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Cd_ppb_MS-BL        Number      Double             Cadmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Ce_ppb_MS-BL        Number      Double             Cerium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Co_ppb_MS-BL        Number      Double             Cobalt, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Cr_ppb_MS-BL        Number      Double             Chromium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Cs_ppb_MS-BL        Number      Double             Cesium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Cu_ppb_MS-BL        Number      Double             Copper, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Dy_ppb_MS-BL        Number      Double             Dysprosium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Er_ppb_MS-BL        Number      Double             Erbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Eu_ppb_MS-BL        Number      Double             Europium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Ga_ppb_MS-BL        Number      Double             Gallium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Gd_ppb_MS-BL        Number      Double             Gadolinium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Ge_ppb_MS-BL        Number      Double             Germanium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Hf_ppb_MS-BL        Number      Double             Hafnium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Hg_ppb_MS-BL        Number      Double             Mercury, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Ho_ppb_MS-BL        Number      Double             Holmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    I_ppb_MS-BL         Number      Double             Iodine, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    In_ppb_MS-BL        Number      Double             Indium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    La_ppb_MS-BL        Number      Double             Lanthanum, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Li_ppb_MS-BL        Number      Double             Lithium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Lu_ppb_MS-BL        Number      Double             Lutetium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Mn_ppb_MS-BL        Number      Double             Manganese, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Mo_ppb_MS-BL        Number      Double             Molybdenum, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Nb_ppb_MS-BL        Number      Double             Niobium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Nd_ppb_MS-BL        Number      Double             Neodymium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Ni_ppb_MS-BL        Number      Double             Nickel, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Os_ppb_MS-BL        Number      Double             Osmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Pb_ppb_MS-BL        Number      Double             Lead, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Pd_ppb_MS-BL        Number      Double             Palladium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Pr_ppb_MS-BL        Number      Double             Praseodymium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Pt_ppb_MS-BL        Number      Double             Platinum, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Rb_ppb_MS-BL        Number      Double             Rubidium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Re_ppb_MS-BL        Number      Double             Rhenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Ru_ppb_MS-BL        Number      Double             Ruthenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Sb_ppb_MS-BL        Number      Double             Antimony, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Sc_ppb_MS-BL        Number      Double             Scandium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Se_ppb_MS-BL        Number      Double             Selenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Sm_ppb_MS-BL        Number      Double             Samarium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Sr_ppb_MS-BL        Number      Double             Strontium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Ta_ppb_MS-BL        Number      Double             Tantalum, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Tb_ppb_MS-BL        Number      Double             Terbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Te_ppb_MS-BL        Number      Double             Tellurium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Th_ppb_MS-BL        Number      Double             Thorium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Tl_ppb_MS-BL        Number      Double             Thallium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Tm_ppb_MS-BL        Number      Double             Thulium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    U_ppb_MS-BL         Number      Double             Uranium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    V_ppb_MS-BL         Number      Double             Vanadium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    W_ppb_MS-BL         Number      Double             Tungsten, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Y_ppb_MS-BL         Number      Double             Yttrium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Yb_ppb_MS-BL        Number      Double             Ytterbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Zn_ppb_MS-BL        Number      Double             Zinc, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    Zr_ppb_MS-BL        Number      Double             Zirconium, in parts per billion, by inductively coupled plasma-mass spectroscopy after BioLeach.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_ICPMS-CHHLch is a table of inductively coupled plasma-mass spectroscopy cold hydroxylamine hydrochloride leach chemical data from soil samples collected and analyzed for the Pebble project.
    FieldName                 FieldType   FieldSize-Format   FieldDescript
    
    SampleID                  Number      Long Integer       Unique sample identifier.
    SampleNumber              Text        20                 Sample number provided by submitter.
    FieldSiteNumber           Text        15                 Unique field site ID assigned by scientist in the field.
    JOB_ID                    Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD          Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD         Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName              Text        15                 Short name of laboratory that performed analysis.
    QA-QC                     Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed            Text        100                Description of actual sample analyzed.
    Ag_ppm_MS-CH              Number      Double             Silver, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Al_ppm_MS-CH              Number      Double             Aluminum, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    As_ppm_MS-CH              Number      Double             Arsenic, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Au_ppm_MS-CH              Number      Double             Gold, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    B_ppm_MS-CH               Number      Double             Boron, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Ba_ppm_MS-CH              Number      Double             Barium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Be_ppm_MS-CH              Number      Double             Beryllium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Bi_ppm_MS-CH              Number      Double             Bismuth, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Br_ppm_MS-CH              Number      Double             Bromine, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Ca_ppm_MS-CH              Number      Double             Calcium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Cd_ppm_MS-CH              Number      Double             Cadmium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Ce_ppm_MS-CH              Number      Double             Cerium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Co_ppm_MS-CH              Number      Double             Cobalt, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Cr_ppm_MS-CH              Number      Double             Chromium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Cs_ppm_MS-CH              Number      Double             Cesium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Cu_ppm_MS-CH              Number      Double             Copper, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Dy_ppm_MS-CH              Number      Double             Dysprosium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Er_ppm_MS-CH              Number      Double             Erbium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Eu_ppm_MS-CH              Number      Double             Europium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Fe_ppm_MS-CH              Number      Double             Iron, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Ga_ppm_MS-CH              Number      Double             Gallium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Gd_ppm_MS-CH              Number      Double             Gadolinium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Ge_ppm_MS-CH              Number      Double             Germanium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Hf_ppm_MS-CH              Number      Double             Hafnium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Hg_ppm_MS-CH              Number      Double             Mercury, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Ho_ppm_MS-CH              Number      Double             Holmium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    I_ppm_MS-CH               Number      Double             Iodine, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    In_ppm_MS-CH              Number      Double             Indium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    K_ppm_MS-CH               Number      Double             Potassium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    La_ppm_MS-CH              Number      Double             Lanthanum, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Li_ppm_MS-CH              Number      Double             Lithium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Lu_ppm_MS-CH              Number      Double             Lutetium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Mg_ppm_MS-CH              Number      Double             Magnesium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Mn_ppm_MS-CH              Number      Double             Manganese, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Mo_ppm_MS-CH              Number      Double             Molybdenum, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Na_ppm_MS-CH              Number      Double             Sodium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Nb_ppm_MS-CH              Number      Double             Niobium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Nd_ppm_MS-CH              Number      Double             Neodymium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Ni_ppm_MS-CH              Number      Double             Nickel, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    P_ppm_MS-CH               Number      Double             Phosphorus, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Pb_ppm_MS-CH              Number      Double             Lead, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Pr_ppm_MS-CH              Number      Double             Praseodymium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Rb_ppm_MS-CH              Number      Double             Rubidium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Re_ppm_MS-CH              Number      Double             Rhenium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Sb_ppm_MS-CH              Number      Double             Antimony, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Se_ppm_MS-CH              Number      Double             Selenium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Sm_ppm_MS-CH              Number      Double             Samarium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Sn_ppm_MS-CH              Number      Double             Tin, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Sr_ppm_MS-CH              Number      Double             Strontium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Ta_ppm_MS-CH              Number      Double             Tantalum, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Tb_ppm_MS-CH              Number      Double             Terbium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Te_ppm_MS-CH              Number      Double             Tellurium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Th_ppm_MS-CH              Number      Double             Thorium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Ti_ppm_MS-CH              Number      Double             Titanium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Tl_ppm_MS-CH              Number      Double             Thallium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Tm_ppm_MS-CH              Number      Double             Thulium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    U_ppm_MS-CH               Number      Double             Uranium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    V_ppm_MS-CH               Number      Double             Vanadium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    W_ppm_MS-CH               Number      Double             Tungsten, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Y_ppm_MS-CH               Number      Double             Yttrium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Yb_ppm_MS-CH              Number      Double             Ytterbium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Zn_ppm_MS-CH              Number      Double             Zinc, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    Zr_ppm_MS-CH              Number      Double             Zirconium, in parts per million, by inductively coupled plasma-mass spectroscopy after cold hydroxylamine hydrochloride leach.
    pH-paste_SI_ISE           Number      Double             pH of paste, in standard units, by digital pH meter in the lab.
    SpCon-paste_uS/cm_Instr   Number      Double             Specific conductivity of paste, in micro-Siemens per centimeter, by conductivity meter.
    pH-lch-fin_SI_ISE         Number      Double             pH of leachate following acid extraction, in standard units, by digital pH meter in the lab.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_ICPMS-EELch is a table of inductively coupled plasma-mass spectroscopy enhanced enzyme leach chemical data from soil samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppb_MS-EZ        Number      Double             Silver, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Al_ppm_MS-EZ        Number      Double             Aluminum, in parts per million, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    As_ppb_MS-EZ        Number      Double             Arsenic, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Au_ppb_MS-EZ        Number      Double             Gold, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Ba_ppb_MS-EZ        Number      Double             Barium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Be_ppb_MS-EZ        Number      Double             Beryllium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Bi_ppb_MS-EZ        Number      Double             Bismuth, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Br_ppb_MS-EZ        Number      Double             Bromine, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Ca_ppm_MS-EZ        Number      Double             Calcium, in parts per million, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Cd_ppb_MS-EZ        Number      Double             Cadmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Ce_ppb_MS-EZ        Number      Double             Cerium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Cl_ppb_MS-EZ        Number      Double             Chlorine, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Co_ppb_MS-EZ        Number      Double             Cobalt, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Cr_ppb_MS-EZ        Number      Double             Chromium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Cs_ppb_MS-EZ        Number      Double             Cesium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Cu_ppb_MS-EZ        Number      Double             Copper, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Dy_ppb_MS-EZ        Number      Double             Dysprosium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Er_ppb_MS-EZ        Number      Double             Erbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Eu_ppb_MS-EZ        Number      Double             Europium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Fe_ppm_MS-EZ        Number      Double             Iron, in parts per million, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Ga_ppb_MS-EZ        Number      Double             Gallium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Gd_ppb_MS-EZ        Number      Double             Gadolinium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Ge_ppb_MS-EZ        Number      Double             Germanium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Hf_ppb_MS-EZ        Number      Double             Hafnium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Hg_ppb_MS-EZ        Number      Double             Mercury, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Ho_ppb_MS-EZ        Number      Double             Holmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    I_ppb_MS-EZ         Number      Double             Iodine, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    In_ppb_MS-EZ        Number      Double             Indium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    K_ppm_MS-EZ         Number      Double             Potassium, in parts per million, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    La_ppb_MS-EZ        Number      Double             Lanthanum, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Li_ppb_MS-EZ        Number      Double             Lithium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Lu_ppb_MS-EZ        Number      Double             Lutetium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Mg_ppm_MS-EZ        Number      Double             Magnesium, in parts per million, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Mn_ppb_MS-EZ        Number      Double             Manganese, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Mo_ppb_MS-EZ        Number      Double             Molybdenum, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Na_ppm_MS-EZ        Number      Double             Sodium, in parts per million, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Nb_ppb_MS-EZ        Number      Double             Niobium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Nd_ppb_MS-EZ        Number      Double             Neodymium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Ni_ppb_MS-EZ        Number      Double             Nickel, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Os_ppb_MS-EZ        Number      Double             Osmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Pb_ppb_MS-EZ        Number      Double             Lead, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Pd_ppb_MS-EZ        Number      Double             Palladium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Pr_ppb_MS-EZ        Number      Double             Praseodymium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Pt_ppb_MS-EZ        Number      Double             Platinum, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Rb_ppb_MS-EZ        Number      Double             Rubidium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Re_ppb_MS-EZ        Number      Double             Rhenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Ru_ppb_MS-EZ        Number      Double             Ruthenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    S_ppm_MS-EZ         Number      Double             Sulfur, in parts per million, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Sb_ppb_MS-EZ        Number      Double             Antimony, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Sc_ppb_MS-EZ        Number      Double             Scandium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Se_ppb_MS-EZ        Number      Double             Selenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Sm_ppb_MS-EZ        Number      Double             Samarium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Sn_ppb_MS-EZ        Number      Double             Tin, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Sr_ppb_MS-EZ        Number      Double             Strontium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Ta_ppb_MS-EZ        Number      Double             Tantalum, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Tb_ppb_MS-EZ        Number      Double             Terbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Te_ppb_MS-EZ        Number      Double             Tellurium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Th_ppb_MS-EZ        Number      Double             Thorium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Ti_ppb_MS-EZ        Number      Double             Titanium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Tl_ppb_MS-EZ        Number      Double             Thallium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Tm_ppb_MS-EZ        Number      Double             Thulium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    U_ppb_MS-EZ         Number      Double             Uranium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    V_ppb_MS-EZ         Number      Double             Vanadium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    W_ppb_MS-EZ         Number      Double             Tungsten, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Y_ppb_MS-EZ         Number      Double             Yttrium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Yb_ppb_MS-EZ        Number      Double             Ytterbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Zn_ppb_MS-EZ        Number      Double             Zinc, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    Zr_ppb_MS-EZ        Number      Double             Zirconium, in parts per billion, by inductively coupled plasma-mass spectroscopy after enhanced enzyme leach.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_ICPMS-FLT is a table of inductively coupled plasma-mass spectroscopy deionized water leach chemical data from soil samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppb_MS-FLT       Number      Double             Silver, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Al_ppm_MS-FLT       Number      Double             Aluminum, in parts per million, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    As_ppb_MS-FLT       Number      Double             Arsenic, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Ba_ppb_MS-FLT       Number      Double             Barium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Be_ppb_MS-FLT       Number      Double             Beryllium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Bi_ppb_MS-FLT       Number      Double             Bismuth, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Ca_ppm_MS-FLT       Number      Double             Calcium, in parts per million, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Cd_ppb_MS-FLT       Number      Double             Cadmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Ce_ppb_MS-FLT       Number      Double             Cerium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Co_ppb_MS-FLT       Number      Double             Cobalt, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Cr_ppb_MS-FLT       Number      Double             Chromium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Cs_ppb_MS-FLT       Number      Double             Cesium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Cu_ppb_MS-FLT       Number      Double             Copper, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Dy_ppb_MS-FLT       Number      Double             Dysprosium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Er_ppb_MS-FLT       Number      Double             Erbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Eu_ppb_MS-FLT       Number      Double             Europium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Fe_ppm_MS-FLT       Number      Double             Iron, in parts per million, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Ga_ppb_MS-FLT       Number      Double             Gallium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Gd_ppb_MS-FLT       Number      Double             Gadolinium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Ge_ppb_MS-FLT       Number      Double             Germanium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Ho_ppb_MS-FLT       Number      Double             Holmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    K_ppm_MS-FLT        Number      Double             Potassium, in parts per million, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    La_ppb_MS-FLT       Number      Double             Lanthanum, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Li_ppb_MS-FLT       Number      Double             Lithium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Lu_ppb_MS-FLT       Number      Double             Lutetium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Mg_ppm_MS-FLT       Number      Double             Magnesium, in parts per million, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Mn_ppb_MS-FLT       Number      Double             Manganese, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Mo_ppb_MS-FLT       Number      Double             Molybdenum, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Na_ppm_MS-FLT       Number      Double             Sodium, in parts per million, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Nb_ppb_MS-FLT       Number      Double             Niobium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Nd_ppb_MS-FLT       Number      Double             Neodymium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Ni_ppb_MS-FLT       Number      Double             Nickel, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    P_ppm_MS-FLT        Number      Double             Phosphorus, in parts per million, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Pb_ppb_MS-FLT       Number      Double             Lead, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Pr_ppb_MS-FLT       Number      Double             Praseodymium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Rb_ppb_MS-FLT       Number      Double             Rubidium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Sb_ppb_MS-FLT       Number      Double             Antimony, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Sc_ppb_MS-FLT       Number      Double             Scandium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Se_ppb_MS-FLT       Number      Double             Selenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    SiO2_ppm_MS-FLT     Number      Double             Silicon, as silicon dioxide, in parts per million, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Sm_ppb_MS-FLT       Number      Double             Samarium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    SO4_ppm_MS-FLT      Number      Double             Sulfate, in parts per million, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Sr_ppb_MS-FLT       Number      Double             Strontium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Ta_ppb_MS-FLT       Number      Double             Tantalum, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Tb_ppb_MS-FLT       Number      Double             Terbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Th_ppb_MS-FLT       Number      Double             Thorium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Ti_ppb_MS-FLT       Number      Double             Titanium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Tl_ppb_MS-FLT       Number      Double             Thallium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Tm_ppb_MS-FLT       Number      Double             Thulium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    U_ppb_MS-FLT        Number      Double             Uranium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    V_ppb_MS-FLT        Number      Double             Vanadium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    W_ppb_MS-FLT        Number      Double             Tungsten, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Y_ppb_MS-FLT        Number      Double             Yttrium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Yb_ppb_MS-FLT       Number      Double             Ytterbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Zn_ppb_MS-FLT       Number      Double             Zinc, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    Zr_ppb_MS-FLT       Number      Double             Zirconium, in parts per billion, by inductively coupled plasma-mass spectroscopy after de-ionized water Field Leach Test.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_ICPMS-ILch is a table of inductively coupled plasma-mass spectroscopy ionic leach chemical data from soil samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppb_MS-IL        Number      Double             Silver, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    As_ppb_MS-IL        Number      Double             Arsenic, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Au_ppb_MS-IL        Number      Double             Gold, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Ba_ppb_MS-IL        Number      Double             Barium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Be_ppb_MS-IL        Number      Double             Beryllium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Bi_ppb_MS-IL        Number      Double             Bismuth, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Br_ppm_MS-IL        Number      Double             Bromine, in parts per million, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Ca_ppm_MS-IL        Number      Double             Calcium, in parts per million, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Cd_ppb_MS-IL        Number      Double             Cadmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Ce_ppb_MS-IL        Number      Double             Cerium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Co_ppb_MS-IL        Number      Double             Cobalt, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Cr_ppb_MS-IL        Number      Double             Chromium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Cs_ppb_MS-IL        Number      Double             Cesium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Cu_ppb_MS-IL        Number      Double             Copper, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Dy_ppb_MS-IL        Number      Double             Dysprosium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Er_ppb_MS-IL        Number      Double             Erbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Eu_ppb_MS-IL        Number      Double             Europium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Fe_ppm_MS-IL        Number      Double             Iron, in parts per million, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Ga_ppb_MS-IL        Number      Double             Gallium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Gd_ppb_MS-IL        Number      Double             Gadolinium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Ge_ppb_MS-IL        Number      Double             Germanium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Hf_ppb_MS-IL        Number      Double             Hafnium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Hg_ppb_MS-IL        Number      Double             Mercury, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Ho_ppb_MS-IL        Number      Double             Holmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    I_ppm_MS-IL         Number      Double             Iodine, in parts per million, by inductively coupled plasma-mass spectroscopy after ionic leach.
    In_ppb_MS-IL        Number      Double             Indium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    La_ppb_MS-IL        Number      Double             Lanthanum, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Li_ppb_MS-IL        Number      Double             Lithium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Lu_ppb_MS-IL        Number      Double             Lutetium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Mg_ppm_MS-IL        Number      Double             Magnesium, in parts per million, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Mn_ppm_MS-IL        Number      Double             Manganese, in parts per million, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Mo_ppb_MS-IL        Number      Double             Molybdenum, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Nb_ppb_MS-IL        Number      Double             Niobium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Nd_ppb_MS-IL        Number      Double             Neodymium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Ni_ppb_MS-IL        Number      Double             Nickel, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Pb_ppb_MS-IL        Number      Double             Lead, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Pb-206_ppb_MS-IL    Number      Double             Lead-206, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Pb-207_ppb_MS-IL    Number      Double             Lead-207, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Pb-208_ppb_MS-IL    Number      Double             Lead-208, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Pd_ppb_MS-IL        Number      Double             Palladium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Pr_ppb_MS-IL        Number      Double             Praseodymium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Rb_ppb_MS-IL        Number      Double             Rubidium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Re_ppb_MS-IL        Number      Double             Rhenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Sb_ppb_MS-IL        Number      Double             Antimony, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Se_ppb_MS-IL        Number      Double             Selenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Sm_ppb_MS-IL        Number      Double             Samarium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Sn_ppb_MS-IL        Number      Double             Tin, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Sr_ppb_MS-IL        Number      Double             Strontium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Ta_ppb_MS-IL        Number      Double             Tantalum, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Tb_ppb_MS-IL        Number      Double             Terbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Te_ppb_MS-IL        Number      Double             Tellurium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Th_ppb_MS-IL        Number      Double             Thorium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Ti_ppb_MS-IL        Number      Double             Titanium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Tl_ppb_MS-IL        Number      Double             Thallium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Tm_ppb_MS-IL        Number      Double             Thulium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    U_ppb_MS-IL         Number      Double             Uranium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    W_ppb_MS-IL         Number      Double             Tungsten, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Y_ppb_MS-IL         Number      Double             Yttrium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Yb_ppb_MS-IL        Number      Double             Ytterbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Zn_ppb_MS-IL        Number      Double             Zinc, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    Zr_ppb_MS-IL        Number      Double             Zirconium, in parts per billion, by inductively coupled plasma-mass spectroscopy after ionic leach.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_ICPMS-MMILch is a table of inductively coupled plasma-mass spectroscopy mobile metal ion leach chemical data from soil samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppb_MS-MM        Number      Double             Silver, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Al_ppm_MS-MM        Number      Double             Aluminum, in parts per million, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    As_ppb_MS-MM        Number      Double             Arsenic, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Au_ppb_MS-MM        Number      Double             Gold, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Ba_ppb_MS-MM        Number      Double             Barium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Bi_ppb_MS-MM        Number      Double             Bismuth, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Ca_ppm_MS-MM        Number      Double             Calcium, in parts per million, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Cd_ppb_MS-MM        Number      Double             Cadmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Ce_ppb_MS-MM        Number      Double             Cerium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Co_ppb_MS-MM        Number      Double             Cobalt, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Cr_ppb_MS-MM        Number      Double             Chromium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Cu_ppb_MS-MM        Number      Double             Copper, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Dy_ppb_MS-MM        Number      Double             Dysprosium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Er_ppb_MS-MM        Number      Double             Erbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Eu_ppb_MS-MM        Number      Double             Europium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Fe_ppm_MS-MM        Number      Double             Iron, in parts per million, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Gd_ppb_MS-MM        Number      Double             Gadolinium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    La_ppb_MS-MM        Number      Double             Lanthanum, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Li_ppb_MS-MM        Number      Double             Lithium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Mg_ppm_MS-MM        Number      Double             Magnesium, in parts per million, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Mo_ppb_MS-MM        Number      Double             Molybdenum, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Nb_ppb_MS-MM        Number      Double             Niobium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Nd_ppb_MS-MM        Number      Double             Neodymium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Ni_ppb_MS-MM        Number      Double             Nickel, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Pb_ppb_MS-MM        Number      Double             Lead, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Pd_ppb_MS-MM        Number      Double             Palladium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Pr_ppb_MS-MM        Number      Double             Praseodymium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Pt_ppb_MS-MM        Number      Double             Platinum, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Rb_ppb_MS-MM        Number      Double             Rubidium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Sb_ppb_MS-MM        Number      Double             Antimony, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Sc_ppb_MS-MM        Number      Double             Scandium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Sm_ppb_MS-MM        Number      Double             Samarium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Sn_ppb_MS-MM        Number      Double             Tin, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Sr_ppb_MS-MM        Number      Double             Strontium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Ta_ppb_MS-MM        Number      Double             Tantalum, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Tb_ppb_MS-MM        Number      Double             Terbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Te_ppb_MS-MM        Number      Double             Tellurium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Th_ppb_MS-MM        Number      Double             Thorium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Ti_ppb_MS-MM        Number      Double             Titanium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Tl_ppb_MS-MM        Number      Double             Thallium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    U_ppb_MS-MM         Number      Double             Uranium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    W_ppb_MS-MM         Number      Double             Tungsten, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Y_ppb_MS-MM         Number      Double             Yttrium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Yb_ppb_MS-MM        Number      Double             Ytterbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Zn_ppb_MS-MM        Number      Double             Zinc, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    Zr_ppb_MS-MM        Number      Double             Zirconium, in parts per billion, by inductively coupled plasma-mass spectroscopy after mobile metal ion leach.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_ICPMS-NaPLch is a table of inductively coupled plasma-mass spectroscopy sodium pyrophosphate leach chemical data from soil samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppm_MS-SP        Number      Double             Silver, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Al_ppm_MS-SP        Number      Double             Aluminum, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    As_ppm_MS-SP        Number      Double             Arsenic, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Au_ppm_MS-SP        Number      Double             Gold, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    B_ppm_MS-SP         Number      Double             Boron, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Ba_ppm_MS-SP        Number      Double             Barium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Be_ppm_MS-SP        Number      Double             Beryllium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Bi_ppm_MS-SP        Number      Double             Bismuth, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Br_ppm_MS-SP        Number      Double             Bromine, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Ca_ppm_MS-SP        Number      Double             Calcium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Cd_ppm_MS-SP        Number      Double             Cadmium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Ce_ppm_MS-SP        Number      Double             Cerium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Co_ppm_MS-SP        Number      Double             Cobalt, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Cr_ppm_MS-SP        Number      Double             Chromium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Cs_ppm_MS-SP        Number      Double             Cesium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Cu_ppm_MS-SP        Number      Double             Copper, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Dy_ppm_MS-SP        Number      Double             Dysprosium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Er_ppm_MS-SP        Number      Double             Erbium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Eu_ppm_MS-SP        Number      Double             Europium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Fe_ppm_MS-SP        Number      Double             Iron, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Ga_ppm_MS-SP        Number      Double             Gallium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Gd_ppm_MS-SP        Number      Double             Gadolinium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Ge_ppm_MS-SP        Number      Double             Germanium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Hf_ppm_MS-SP        Number      Double             Hafnium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Hg_ppm_MS-SP        Number      Double             Mercury, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Ho_ppm_MS-SP        Number      Double             Holmium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    I_ppm_MS-SP         Number      Double             Iodine, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    In_ppm_MS-SP        Number      Double             Indium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    K_ppm_MS-SP         Number      Double             Potassium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    La_ppm_MS-SP        Number      Double             Lanthanum, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Li_ppm_MS-SP        Number      Double             Lithium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Lu_ppm_MS-SP        Number      Double             Lutetium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Mg_ppm_MS-SP        Number      Double             Magnesium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Mn_ppm_MS-SP        Number      Double             Manganese, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Mo_ppm_MS-SP        Number      Double             Molybdenum, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Nb_ppm_MS-SP        Number      Double             Niobium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Nd_ppm_MS-SP        Number      Double             Neodymium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Ni_ppm_MS-SP        Number      Double             Nickel, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Pb_ppm_MS-SP        Number      Double             Lead, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Pr_ppm_MS-SP        Number      Double             Praseodymium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Rb_ppm_MS-SP        Number      Double             Rubidium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Re_ppm_MS-SP        Number      Double             Rhenium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Sb_ppm_MS-SP        Number      Double             Antimony, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Se_ppm_MS-SP        Number      Double             Selenium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Sm_ppm_MS-SP        Number      Double             Samarium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Sn_ppm_MS-SP        Number      Double             Tin, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Sr_ppm_MS-SP        Number      Double             Strontium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Ta_ppm_MS-SP        Number      Double             Tantalum, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Tb_ppm_MS-SP        Number      Double             Terbium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Te_ppm_MS-SP        Number      Double             Tellurium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Th_ppm_MS-SP        Number      Double             Thorium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Ti_ppm_MS-SP        Number      Double             Titanium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Tl_ppm_MS-SP        Number      Double             Thallium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Tm_ppm_MS-SP        Number      Double             Thulium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    U_ppm_MS-SP         Number      Double             Uranium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    V_ppm_MS-SP         Number      Double             Vanadium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    W_ppm_MS-SP         Number      Double             Tungsten, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Y_ppm_MS-SP         Number      Double             Yttrium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Yb_ppm_MS-SP        Number      Double             Ytterbium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Zn_ppm_MS-SP        Number      Double             Zinc, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    Zr_ppm_MS-SP        Number      Double             Zirconium, in parts per million, by inductively coupled plasma-mass spectroscopy after sodium pyrophosphate leach.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_ICPMS-TSLch is a table of inductively coupled plasma-mass spectroscopy TerraSol leach chemical data from soil samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    LAB_ID              Text        10                 Number assigned by analytical lab, from LIMS.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppb_MS-TL        Number      Double             Silver, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Al_ppm_MS-TL        Number      Double             Aluminum, in parts per million, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    As_ppb_MS-TL        Number      Double             Arsenic, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Au_ppb_MS-TL        Number      Double             Gold, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Ba_ppb_MS-TL        Number      Double             Barium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Be_ppb_MS-TL        Number      Double             Beryllium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Bi_ppb_MS-TL        Number      Double             Bismuth, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Ca_ppm_MS-TL        Number      Double             Calcium, in parts per million, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Cd_ppb_MS-TL        Number      Double             Cadmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Ce_ppb_MS-TL        Number      Double             Cerium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Cl_ppb_MS-TL        Number      Double             Chlorine, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Co_ppb_MS-TL        Number      Double             Cobalt, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Cr_ppb_MS-TL        Number      Double             Chromium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Cs_ppb_MS-TL        Number      Double             Cesium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Cu_ppb_MS-TL        Number      Double             Copper, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Dy_ppb_MS-TL        Number      Double             Dysprosium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Er_ppb_MS-TL        Number      Double             Erbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Eu_ppb_MS-TL        Number      Double             Europium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Fe_ppm_MS-TL        Number      Double             Iron, in parts per million, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Ga_ppb_MS-TL        Number      Double             Gallium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Gd_ppb_MS-TL        Number      Double             Gadolinium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Ge_ppb_MS-TL        Number      Double             Germanium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Hf_ppb_MS-TL        Number      Double             Hafnium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Hg_ppb_MS-TL        Number      Double             Mercury, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Ho_ppb_MS-TL        Number      Double             Holmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    In_ppb_MS-TL        Number      Double             Indium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Ir_ppb_MS-TL        Number      Double             Iridium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    K_ppm_MS-TL         Number      Double             Potassium, in parts per million, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    La_ppb_MS-TL        Number      Double             Lanthanum, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Li_ppb_MS-TL        Number      Double             Lithium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Lu_ppb_MS-TL        Number      Double             Lutetium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Mg_ppm_MS-TL        Number      Double             Magnesium, in parts per million, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Mn_ppb_MS-TL        Number      Double             Manganese, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Mo_ppb_MS-TL        Number      Double             Molybdenum, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Na_ppm_MS-TL        Number      Double             Sodium, in parts per million, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Nb_ppb_MS-TL        Number      Double             Niobium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Nd_ppb_MS-TL        Number      Double             Neodymium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Ni_ppb_MS-TL        Number      Double             Nickel, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Os_ppb_MS-TL        Number      Double             Osmium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Pb_ppb_MS-TL        Number      Double             Lead, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Pd_ppb_MS-TL        Number      Double             Palladium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Pr_ppb_MS-TL        Number      Double             Praseodymium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Pt_ppb_MS-TL        Number      Double             Platinum, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Rb_ppb_MS-TL        Number      Double             Rubidium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Re_ppb_MS-TL        Number      Double             Rhenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Rh_ppb_MS-TL        Number      Double             Rhodium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Ru_ppb_MS-TL        Number      Double             Ruthenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    S_ppm_MS-TL         Number      Double             Sulfur, in parts per million, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Sb_ppb_MS-TL        Number      Double             Antimony, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Sc_ppb_MS-TL        Number      Double             Scandium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Se_ppb_MS-TL        Number      Double             Selenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Sm_ppb_MS-TL        Number      Double             Samarium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Sn_ppb_MS-TL        Number      Double             Tin, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Sr_ppb_MS-TL        Number      Double             Strontium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Ta_ppb_MS-TL        Number      Double             Tantalum, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Te_ppb_MS-TL        Number      Double             Tellurium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Th_ppb_MS-TL        Number      Double             Thorium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Ti_ppb_MS-TL        Number      Double             Titanium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Tl_ppb_MS-TL        Number      Double             Thallium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Tm_ppb_MS-TL        Number      Double             Thulium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    U_ppb_MS-TL         Number      Double             Uranium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    V_ppb_MS-TL         Number      Double             Vanadium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    W_ppb_MS-TL         Number      Double             Tungsten, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Y_ppb_MS-TL         Number      Double             Yttrium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Yb_ppb_MS-TL        Number      Double             Ytterbium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Zn_ppb_MS-TL        Number      Double             Zinc, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    Zr_ppb_MS-TL        Number      Double             Zirconium, in parts per billion, by inductively coupled plasma-mass spectroscopy after TerraSol leach.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Soil_pH-SpCond is a table of pH and conductance data for soil samples collected and analyzed for the Pebble project.
    FieldName                 FieldType   FieldSize-Format   FieldDescript
    
    SampleID                  Number      Long Integer       Unique sample identifier.
    SampleNumber              Text        20                 Sample number provided by submitter.
    FieldSiteNumber           Text        15                 Unique field site ID assigned by scientist in the field.
    FieldLatitude_DD          Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD         Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName              Text        15                 Short name of laboratory that performed analysis.
    QA-QC                     Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed            Text        100                Description of actual sample analyzed.
    pH-paste_SI_ISE           Number      Double             pH of paste, in standard units, by digital pH meter in the lab.
    SpCon-paste_uS/cm_Instr   Number      Double             Specific conductivity of paste, in micro-Siemens per centimeter, by conductivity meter.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Veg_ICPMS-AR is a table of inductively coupled plasma-mass spectroscopy aqua regia leach chemical data from vegetation samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppb_MS-AR        Number      Double             Silver, in parts per billion, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Al_pct_MS-AR        Number      Double             Aluminum, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    As_ppm_MS-AR        Number      Double             Arsenic, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Au_ppb_MS-AR        Number      Double             Gold, in parts per billion, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    B_ppm_MS-AR         Number      Double             Boron, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ba_ppm_MS-AR        Number      Double             Barium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Be_ppm_MS-AR        Number      Double             Beryllium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Bi_ppm_MS-AR        Number      Double             Bismuth, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ca_pct_MS-AR        Number      Double             Calcium, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Cd_ppm_MS-AR        Number      Double             Cadmium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ce_ppm_MS-AR        Number      Double             Cerium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Co_ppm_MS-AR        Number      Double             Cobalt, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Cr_ppm_MS-AR        Number      Double             Chromium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Cs_ppm_MS-AR        Number      Double             Cesium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Cu_ppm_MS-AR        Number      Double             Copper, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Fe_pct_MS-AR        Number      Double             Iron, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ga_ppm_MS-AR        Number      Double             Gallium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ge_ppm_MS-AR        Number      Double             Germanium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Hf_ppm_MS-AR        Number      Double             Hafnium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Hg_ppb_MS-AR        Number      Double             Mercury, in parts per billion, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    In_ppm_MS-AR        Number      Double             Indium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    K_pct_MS-AR         Number      Double             Potassium, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    La_ppm_MS-AR        Number      Double             Lanthanum, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Li_ppm_MS-AR        Number      Double             Lithium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Mg_pct_MS-AR        Number      Double             Magnesium, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Mn_ppm_MS-AR        Number      Double             Manganese, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Mo_ppm_MS-AR        Number      Double             Molybdenum, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Na_pct_MS-AR        Number      Double             Sodium, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Nb_ppm_MS-AR        Number      Double             Niobium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ni_ppm_MS-AR        Number      Double             Nickel, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    P_pct_MS-AR         Number      Double             Phosphorus, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Pb_ppm_MS-AR        Number      Double             Lead, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Pd_ppb_MS-AR        Number      Double             Palladium, in parts per billion, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Pt_ppb_MS-AR        Number      Double             Platinum, in parts per billion, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Rb_ppm_MS-AR        Number      Double             Rubidium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Re_ppb_MS-AR        Number      Double             Rhenium, in parts per billion, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    S_pct_MS-AR         Number      Double             Sulfur, in weight percent, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sb_ppm_MS-AR        Number      Double             Antimony, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sc_ppm_MS-AR        Number      Double             Scandium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Se_ppm_MS-AR        Number      Double             Selenium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sn_ppm_MS-AR        Number      Double             Tin, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sr_ppm_MS-AR        Number      Double             Strontium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ta_ppm_MS-AR        Number      Double             Tantalum, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Te_ppm_MS-AR        Number      Double             Tellurium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Th_ppm_MS-AR        Number      Double             Thorium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ti_ppm_MS-AR        Number      Double             Titanium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Tl_ppm_MS-AR        Number      Double             Thallium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    U_ppm_MS-AR         Number      Double             Uranium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    V_ppm_MS-AR         Number      Double             Vanadium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    W_ppm_MS-AR         Number      Double             Tungsten, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Y_ppm_MS-AR         Number      Double             Yttrium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Zn_ppm_MS-AR        Number      Double             Zinc, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Zr_ppm_MS-AR        Number      Double             Zirconium, in parts per million, by inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.
    Entity_and_Attribute_Overview:
    The table Veg_ICPMS-HR-AR is a table of high resolution inductively coupled plasma-mass spectroscopy aqua regia leach chemical data from vegetation samples collected and analyzed for the Pebble project.
    FieldName           FieldType   FieldSize-Format   FieldDescript
    
    SampleID            Number      Long Integer       Unique sample identifier.
    SampleNumber        Text        20                 Sample number provided by submitter.
    FieldSiteNumber     Text        15                 Unique field site ID assigned by scientist in the field.
    JOB_ID              Text        20                 Job or lot number assigned by analytical lab, from LIMS.
    FieldLatitude_DD    Number      Decimal            Latitude from field, in decimal degrees.
    FieldLongitude_DD   Number      Decimal            Longitude from field, in decimal degrees.
    LabShortName        Text        15                 Short name of laboratory that performed analysis.
    QA-QC               Text        50                 Quality assurance and quality control information regarding sample.
    SampleAnalyzed      Text        100                Description of actual sample analyzed.
    Ag_ppb_MS-HR-AR     Number      Double             Silver, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    As_ppb_MS-HR-AR     Number      Double             Arsenic, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Au_ppb_MS-HR-AR     Number      Double             Gold, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    B_ppb_MS-HR-AR      Number      Double             Boron, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ba_ppm_MS-HR-AR     Number      Double             Barium, in parts per million, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Be_ppb_MS-HR-AR     Number      Double             Beryllium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Bi_ppb_MS-HR-AR     Number      Double             Bismuth, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ca_ppm_MS-HR-AR     Number      Double             Calcium, in parts per million, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Cd_ppb_MS-HR-AR     Number      Double             Cadmium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ce_ppb_MS-HR-AR     Number      Double             Cerium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Co_ppb_MS-HR-AR     Number      Double             Cobalt, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Cr_ppb_MS-HR-AR     Number      Double             Chromium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Cs_ppb_MS-HR-AR     Number      Double             Cesium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Cu_ppb_MS-HR-AR     Number      Double             Copper, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Dy_ppb_MS-HR-AR     Number      Double             Dysprosium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Er_ppb_MS-HR-AR     Number      Double             Erbium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Eu_ppb_MS-HR-AR     Number      Double             Europium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Fe_ppm_MS-HR-AR     Number      Double             Iron, in parts per million, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ga_ppb_MS-HR-AR     Number      Double             Gallium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Gd_ppb_MS-HR-AR     Number      Double             Gadolinium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ge_ppm_MS-HR-AR     Number      Double             Germanium, in parts per million, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Hf_ppb_MS-HR-AR     Number      Double             Hafnium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Hg_ppb_MS-HR-AR     Number      Double             Mercury, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ho_ppb_MS-HR-AR     Number      Double             Holmium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    In_ppb_MS-HR-AR     Number      Double             Indium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    K_ppm_MS-HR-AR      Number      Double             Potassium, in parts per million, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    La_ppb_MS-HR-AR     Number      Double             Lanthanum, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Li_ppb_MS-HR-AR     Number      Double             Lithium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Lu_ppb_MS-HR-AR     Number      Double             Lutetium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Mg_ppm_MS-HR-AR     Number      Double             Magnesium, in parts per million, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Mn_ppb_MS-HR-AR     Number      Double             Manganese, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Mo_ppb_MS-HR-AR     Number      Double             Molybdenum, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Na_ppm_MS-HR-AR     Number      Double             Sodium, in parts per million, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Nb_ppb_MS-HR-AR     Number      Double             Niobium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Nd_ppb_MS-HR-AR     Number      Double             Neodymium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ni_ppm_MS-HR-AR     Number      Double             Nickel, in parts per million, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Pb_ppb_MS-HR-AR     Number      Double             Lead, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Pr_ppb_MS-HR-AR     Number      Double             Praseodymium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Rb_ppb_MS-HR-AR     Number      Double             Rubidium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Re_ppb_MS-HR-AR     Number      Double             Rhenium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sb_ppb_MS-HR-AR     Number      Double             Antimony, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sc_ppb_MS-HR-AR     Number      Double             Scandium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Se_ppm_MS-HR-AR     Number      Double             Selenium, in parts per million, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sm_ppb_MS-HR-AR     Number      Double             Samarium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sn_ppb_MS-HR-AR     Number      Double             Tin, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Sr_ppb_MS-HR-AR     Number      Double             Strontium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ta_ppb_MS-HR-AR     Number      Double             Tantalum, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Tb_ppb_MS-HR-AR     Number      Double             Terbium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Te_ppb_MS-HR-AR     Number      Double             Tellurium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Th_ppb_MS-HR-AR     Number      Double             Thorium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Ti_ppb_MS-HR-AR     Number      Double             Titanium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Tl_ppb_MS-HR-AR     Number      Double             Thallium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Tm_ppb_MS-HR-AR     Number      Double             Thulium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    U_ppb_MS-HR-AR      Number      Double             Uranium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    V_ppb_MS-HR-AR      Number      Double             Vanadium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    W_ppb_MS-HR-AR      Number      Double             Tungsten, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Y_ppb_MS-HR-AR      Number      Double             Yttrium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Yb_ppb_MS-HR-AR     Number      Double             Ytterbium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Zn_ppm_MS-HR-AR     Number      Double             Zinc, in parts per million, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    Zr_ppb_MS-HR-AR     Number      Double             Zirconium, in parts per billion, by high resolution inductively coupled plasma-mass spectroscopy after aqua regia digestion.
    
    Entity_and_Attribute_Detail_Citation:
    database designer/metadata author Matthew Granitto; see Data_Quality_Information/Lineage/Process_Step/Process_Contact/Contact_Information.


Who produced the data set?

  1. Who are the originators of the data set? (may include formal authors, digital compilers, and editors)

  2. Who also contributed to the data set?

    Matthew Granitto

  3. To whom should users address questions about the data?

    Matthew Granitto
    U.S. Geological Survey
    Box 25046, Denver Federal Center, MS 973
    Denver, Colorado 80225
    United States of America

    1-303-236-1412 (voice)
    1-303-236-3200 (FAX)
    granitto@usgs.gov


Why was the data set created?

This database was initiated, designed, and populated to collect and integrate geochemical data from Pebble deposit area, Alaska in order to facilitate geologic mapping, petrologic studies, mineral resource assessment, defining geochemical baseline values and statistics, environmental impact assessment, and medical geology.


How was the data set created?

  1. From what previous works were the data drawn?

  2. How were the data generated, processed, and modified?

    Date: 2008 (process 1 of 1)
    The data were generated by the analytical laboratories of the USGS and USGS contractors during 2007-2011. Data were transmitted to a data-staging database during 2008-2011 where data were mapped to uniform field definitions.

    Person who carried out this activity:

    Matthew Granitto
    U.S. Geological Survey
    Box 25046, Denver Federal Center, MS 973
    Denver, Colorado 80225
    United States of America

    1-303-236-1412 (voice)
    1-303-236-3200 (FAX)
    granitto@usgs.gov

  3. What similar or related data should the user be aware of?

    U.S. Geological Survey (USGS), 2011, Geophysical, Geochemical, and Mineralogical Data from the Pebble Cu-Au-Mo Porphyry Deposit Area, Southwest Alaska: Contributions to Assessment Techniques for Concealed Mineral Resources: U.S. Geological Survey Data Series 608, U.S. Geological Survey, Denver, CO.


How reliable are the data; what problems remain in the data set?

  1. How well have the observations been checked?

    The data of this dataset represent analyses of geologic, aqueous, and organic material samples collected in support of the Pebble porphyry copper-gold-molydenum (Cu-Au-Mo) deposit in southwest Alaska. The samples in this dataset were chemically and mineralogically analyzed by USGS laboratories and USGS-contracted laboratories over the period 2007-2011. Analytical techniques have been documented in USGS and private laboratory publications. For some elements, the methods of chemical analysis were the same throughout the study, while for others, the methods were used during one year of the study.

    1) Coordinates: When samples were brought in for analysis, the submitter was required to include information about the sample for the database; descriptions, geocoding, and latitude-longitude coordinates. The sample location field sites were located using GPS receivers.  The locations determined by GPS should be accurate to the nearest latitude or longitude second.
    2) Geocoding: The submission of sample descriptive information (geocoding) with samples was mandatory for some fields and optional for others.
    3) Analytical Data: The samples in this data set were chemically analyzed by a variety of techniques over a period of time from 2007 to 2011. The accuracy of the data varies with the analytical methodology and with the concentration of the element being analyzed.
    4) Qualifiers: A qualifier such as "<" (less than the detection limit of the analytical method) or ">" (greater than the upper determination limit of the analytical method) accompanies some analytical data values. These qualifiers are defined as follows:
    "<" = the element concentration was determined to be less than the lower determination limit for the method for this element. The value of the lower limit of determination is given in the adjacent data field.
    ">" = the element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field.
    

  2. How accurate are the geographic locations?

    1) Coordinates: submitted samples were located using GPS receivers. The locations determined by GPS should be accurate to the nearest latitude or longitude second.
    2) Datum and Earth Ellipsoid or Spheroid: the datum and spheroid are WGS84 and are identified in two fields that accompany the locational coordinates.

  3. How accurate are the heights or depths?

  4. Where are the gaps in the data? What is missing?

    This data set provides chemical data for Ag, Al, As, Au, B, Ba, Be, Bi, Br, Ca, Cd, Ce, Cl, Co, Cr, Cs, Cu, Dy, Er, Eu, Fe, Fe(II), Fe(III), Ga, Gd, Ge, F, Hf, Hg, Ho, I, In, Ir, K, La, Li, Lu, Mg, Mn, Mo, Na, Nb, Nd, Ni, NO3, Os, P, Pb, Pd, Pr, Pt, Rb, Re, Rh, Ru, S, Sb, Sc, Se, Si, Sm, Sn, SO4, Sr, Ta, Tb, Te, Th, Ti, Tl, Tm, U, V, W, Y, Yb, Zn, Zr, forms of carbon, acidity, alkalinity, conductance, dissolved oxygen, turbidity, stream discharge and pH. It also provides mineralogic data for a wide range of parameters such as relative mineral abundance, mineral grain count, gold grain measurement, sample fraction weight, sample fraction abundance, sample fraction color, sample fraction particle size, and sample fraction composition. In addition, the data set provides location and descriptive information for each sample. Not all the descriptive fields contain information for a particular sample because it was not recorded by the submitter or because it was never entered into the database. No sample will contain analyses for all possible elements. The analytical methods used were selected by the sample submitter based on the goals of the individual project and will vary throughout the data set. The analytical methods, sample preparation protocols, and quality control protocols used for various sample media by the USGS are documented in the following publications:
    Acme Analytical Laboratories (Vancouver) Ltd., 852 East Hastings Street, Vancouver, BC V6A 1R6 Canada, 2011, Thirty-six elements are determined in solids by inductively coupled plasma-mass spectroscopy after aqua regia digestion: Acme analytic method Group 1VE1-MS, p. 29-31; accessed January 12, 2011 at <http://acmelab.com/pdfs/Acme_Price_Brochure.pdf>.
    Acme Analytical Laboratories (Vancouver) Ltd., 852 East Hastings Street, Vancouver, BC V6A 1R6 Canada, 2011, Fifty-three elements are determined in raw organic media by inductively coupled plasma-mass spectroscopy after aqua regia digestion: Acme analytic method Group 1VE2-MS, p. 29-31; accessed January 12, 2011 at <http://acmelab.com/pdfs/Acme_Price_Brochure.pdf>.
    Activation Laboratories Ltd., 1336 Sandhill Drive, Ancaster, ON L9G 4V5, Canada, 2011, Hydrocarbon compounds in solids are determined by proprietary method using gas chromatography and mass spectroscopy in a weak leach simulation: Actlabs analytic method accessed January 12, 2011 at <http://www.Actlabs.com/page.aspx?menu=74&app=244&cat1=591&tp=2&lk=no>.
    Activation Laboratories Ltd., 1336 Sandhill Drive, Ancaster, ON L9G 4V5, Canada, 2011, Fifty-eight constituents are determined in proprietary BioLeach leachates of solids by inductively coupled plasma-mass spectroscopy: Actlabs analytic method accessed January 12, 2011 at <http://www.Actlabs.com/page.aspx?menu=74&app=244&cat1=599&tp=2&lk=no>.
    Activation Laboratories Ltd., 1336 Sandhill Drive, Ancaster, ON L9G 4V5, Canada, 2011, Sixty elements are determined in water by high resolution inductively coupled plasma-mass spectroscopy: Actlabs analytic method accessed January 12, 2011 at <http://www.Actlabs.com/page.aspx?menu=74&app=244&cat1=760&tp=2&lk=no>.
    Activation Laboratories Ltd., 1336 Sandhill Drive, Ancaster, ON L9G 4V5, Canada, 2011, Sixty elements are determined in raw organic media by high resolution inductively coupled plasma-mass spectroscopy after 2-stage HNO3 and aqua regia digestion: Actlabs analytic method accessed January 12, 2011 at <http://www.Actlabs.com/page.aspx?menu=74&app=244&cat1=592&tp=2&lk=no>.
    ALS Minerals, 5420 Mainway Drive - Unit 5, Burlington, ON L7L 6A4 Canada, 2011, Sixty-three constituents are determined in cold hydroxylamine hydrochloride leachates of solids by inductively coupled plasma-mass spectroscopy: ALS-Minerals analytic method accessed January 12, 2011 at <http://www.alsglobal.com/mineralDownloads.aspx>.
    ALS Minerals, 5420 Mainway Drive - Unit 5, Burlington, ON L7L 6A4 Canada, 2011, Fifty-eight elements are determined in pH controlled ionic leachates of solids by inductively coupled plasma-mass spectroscopy: ALS-Minerals analytic method accessed January 12, 2011 at <http://www.alsglobal.com/mineralDownloads.aspx>.
    ALS Minerals, 5420 Mainway Drive - Unit 5, Burlington, ON L7L 6A4 Canada, 2011, Sixty-one constituents are determined in sodium pyrophosphate leachates of solids by inductively coupled plasma-mass spectroscopy: ALS-Minerals analytic method accessed January 12, 2011 at <http://www.alsglobal.com/mineralDownloads.aspx>.
    Arbogast, Belinda F., editor, 1996, Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey: U.S. Geological Survey open-file report 96-525, xi, 248 leaves; 28 cm, accessed January 12, 2011 at <http://pubs.er.usgs.gov/usgspubs/ofr/ofr96525>.
    Aruscavage, Philip J., 1996, Choride by ion-selective electrode following KMnO4-H2SO4-HF dissolution, in Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey: U.S. Geological Survey open-file report 96-525, p. 191-194, accessed January 12, 2011 at <http://pubs.er.usgs.gov/usgspubs/ofr/ofr96525>.
    Briggs, Paul H., 2002, The determination of twenty-seven elements in aqueous samples by inductively coupled plasma-atomic emission spectrometry, in Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey: U.S. Geological Survey open-file report 02-223, p. F1-F11, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/F0203ICPAES_M.pdf>.
    Briggs, Paul H., and Meier, Allen L., 1999, The determination of forty two elements in geological materials by inductively coupled plasma - mass spectrometry: U.S. Geological Survey open-file report 99-166, 15 leaves; 28 cm, accessed January 12, 2011 at <http://pubs.er.usgs.gov/usgspubs/ofr/ofr99166>.
    Briggs, Paul H., and Meier, Allen L., 2002, The determination of forty-two elements in geological materials by inductively coupled plasma-mass spectrometry, in Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey: U.S. Geological Survey open-file report 02-223, p. I1-I14, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/I20NAWQAPlus_M.pdf>.
    Brown, Zoe Ann, and Curry, Kenneth J., 2002, Total carbon by combustion, in Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey: U.S. Geological Survey open-file report 02-223, p. R1-R4, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/R10TotalCarbon_M.pdf>.
    Brown, Zoe Ann, O'Leary, Richard M., Hageman, Philip L., and Crock, James G., 2002, Mercury in water, geologic, and plant materials by continuous flow-cold vapor-atomic absorption spectrometry, in Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey: U.S. Geological Survey open-file report 02-223, p. M1-M9, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/M12HgCV_M.pdf>.
    Brown, Zoe Ann, Papp, Clara S.E., Brandt, Elaine L., and Aruscavage, Philip J., 2002, Carbonate carbon by coulometric titration, in Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey: U.S. Geological Survey open-file report 02-223, p. S1-S6, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/S08CarbonateCarbon_S.pdf>.
    Burt, Rebecca, editor, 2004, Saturated paste pH, analytic method 4C1a1a2, in Soil Survey Laboratory Methods Manual, Soil Survey Investigations Report, No. 42, Version 4.0, November 2004; accessed January 12, 2011 at <ftp://ftp-fc.sc.egov.usda.gov/NSSC/Lab_Methods_Manual/SSIR42_2004_view.pdf>.
    Burt, Rebecca, editor, 2004, Saturated paste conductivity, analytic method 8A1a, in Soil Survey Laboratory Methods Manual, Soil Survey Investigations Report, No. 42, Version 4.0, November 2004; accessed January 12, 2011 at <ftp://ftp-fc.sc.egov.usda.gov/NSSC/Lab_Methods_Manual/SSIR42_2004_view.pdf>.
    Crock, James G., 2005, Determination of total mercury in biological and geological samples a presentation for the 2004 Teledyne Leeman Labs "Seminar on Low-Level Mercury Data and Analyses": U.S. Geological Survey open-file report 2005-1030, , accessed January 12, 2011 at <http://pubs.usgs.gov/of/2005/1030/>.
    Curry, Kenneth J., 1996, Total carbon by combustion, in Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey: U.S. Geological Survey open-file report 96-525, p. 173-176, accessed January 12, 2011 at <http://pubs.er.usgs.gov/usgspubs/ofr/ofr96525>.
    d'Angelo, William M., and Ficklin, Walter H., 1996, Fluoride, chloride, nitrate, and sulfate in aqeous solution by chemically suppressed ion chromatography, in Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey: U.S. Geological Survey open-file report 96-525, p. 149-153, accessed January 12, 2011 at <http://pubs.er.usgs.gov/usgspubs/ofr/ofr96525>.
    Ficklin, Walter H., and Mosier, Elwin L., 1999, Field methods for sampling and analysis of environmental samples for unstable and selected stable constituents, in Plumlee, G.S., and Logsdon, M.J., The environmental geochemistry of mineral deposits: Society of Economic Geologists, Reviews in Economic Geology, v. 6A, p. 249-264.
    Hageman, Philip L., 2002, Mercury in water by flow injection-cold vapor-atomic fluorescence spectrometry, in Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey: U.S. Geological Survey open-file report 02-223, p. N1-N5, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/N13HagemanMercury_M.pdf>.
    Hageman, Philip L., 2007, U.S. Geological Survey field leach test for assessing water reactivity and leaching potential of mine wastes, soils, and other geologic and environmental materials: Techniques of water resources investigations of the United States Geological Survey bk. 5, D-3, v, 14 p.: ill. (some col.); 28 cm, accessed January 12, 2011 at <http://pubs.usgs.gov/tm/2007/05D03/>.
    Hageman, Philip L., and Briggs, Paul H., 2000, A simple field leach test for rapid screening and qualitative characterization of mine waste dump material on abandoned mine lands: U.S. Geological Survey open-file report 00-15, 13 leaves: ill.; 28 cm, accessed January 12, 2011 at <http://pubs.er.usgs.gov/usgspubs/ofr/ofr0015>.
    Hageman, Philip L., and Welsch, Eric P., 1996, Arsenic, antimony, and selenium by flow injection or continuous flow-hydride generation-atomic absorption spectrophometry, in Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey: U.S. Geological Survey open-file report 96-525, p. 24-30, accessed January 12, 2011 at <http://pubs.er.usgs.gov/usgspubs/ofr/ofr96525>.
    Hageman, Philip L., Brown, Zoe Ann, and Welsch, Eric P., 2002, Arsenic and selenium by flow injection or continuous flow-hydride generation-atomic absorption spectrophotometry, in Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey: U.S. Geological Survey open-file report 02-223, p. L1-L7, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/L06AS24Se_M.pdf>.
    Lamothe, Paul J., Meier, Allen L., and Wilson, Stephen A., 1999, The determination of forty four elements in aqueous samples by inductively coupled plasma-mass spectrometry: U.S. Geological Survey open-file report 99-151, 14 leaves; 28 cm, accessed January 12, 2011 at <http://pubs.er.usgs.gov/usgspubs/ofr/ofr99151>.
    Lamothe, Paul J., Meier, Allen L., and Wilson, Stephen A., 2002, The determination of forty elements in aqueous samples by inductively coupled plasma-mass spectrometry, in Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey: U.S. Geological Survey open-file report 02-223, p. H1-H11, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/H21&23OFR99-151_M.pdf>.
    O'Leary, Richard M., Hageman, Philip L., and Crock, James G., 1996, Mercury in water, geologic, and plant materials by continuous flow-cold vapor-atomic absorption spectrometry, in Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey: U.S. Geological Survey open-file report 96-525, p. 42-50, accessed January 12, 2011 at <http://pubs.er.usgs.gov/usgspubs/ofr/ofr96525>.
    Papp, Clara S.E., Brandt, Elaine L., and Aruscavage, Philip J., 1996, Carbonate carbon by coulometric titration, in Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey: U.S. Geological Survey open-file report 96-525, p. 60-66, accessed January 12, 2011 at <http://pubs.er.usgs.gov/usgspubs/ofr/ofr96525>.
    Peacock, Thomas R., 1992, The preparation of plant material and determination of weight percent ash: U.S. Geological Survey open-file report 92-345, 9 leaves: ill.; 28 cm, accessed January 12, 2011 at <http://pubs.er.usgs.gov/usgspubs/ofr/ofr92345>.
    Peacock, Thomas R., 1996, The preparation of plant material and determination of weight percent ash; in Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Taggart, Joseph E., editor, 2002, Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Sur: U.S. Geological Survey open-file report 02-223, , accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/>.
    SGS Minerals Services, 1885 Leslie Street, Toronto, ON M3B 2M3, Canada, 2011, 42 Element ICP-AES-MS multi-acid, total: SGS Analytical Contract Laboratory Method 19, , accessed January 12, 2011 at <http://minerals.cr.usgs.gov/intranet/chem/labmethods.html#M19>.
    SGS Minerals Services, 1885 Leslie Street, Toronto, ON M3B 2M3, Canada, 2011, 55 Element ICP-AES-MS sodium peroxide sinter: SGS Analytical Contract Laboratory Method 22, , accessed January 12, 2011 at <http://minerals.cr.usgs.gov/intranet/chem/labmethods.html#m22>.
    SGS Minerals Services, 1885 Leslie Street, Toronto, ON M3B 2M3, Canada, 2011, Arsenic and Antimony: SGS Analytical Contract Laboratory Methods 9 & 11, , accessed January 12, 2011 at <http://minerals.cr.usgs.gov/intranet/chem/labmethods.html#M9>.
    SGS Minerals Services, 1885 Leslie Street, Toronto, ON M3B 2M3, Canada, 2011, Carbonate Carbon: SGS Analytical Contract Laboratory Method 3-B, , accessed January 12, 2011 at <http://minerals.cr.usgs.gov/intranet/chem/labmethods.html#M3b>.
    SGS Minerals Services, 1885 Leslie Street, Toronto, ON M3B 2M3, Canada, 2011, Chloride (Cl): SGS Analytical Contract Laboratory Method 18, , accessed January 12, 2011 at <http://minerals.cr.usgs.gov/intranet/chem/labmethods.html#M18>.
    SGS Minerals Services, 1885 Leslie Street, Toronto, ON M3B 2M3, Canada, 2011, Fluoride: SGS Analytical Contract Laboratory Method 16, , accessed January 12, 2011 at <http://minerals.cr.usgs.gov/intranet/chem/labmethods.html#M16>.
    SGS Minerals Services, 1885 Leslie Street, Toronto, ON M3B 2M3, Canada, 2011, Gold: SGS Analytical Contract Laboratory Method 7, , accessed January 12, 2011 at <http://minerals.cr.usgs.gov/intranet/chem/labmethods.html#M7>.
    SGS Minerals Services, 1885 Leslie Street, Toronto, ON M3B 2M3, Canada, 2011, Mercury: SGS Analytical Contract Laboratory Method 8, , accessed January 12, 2011 at <http://minerals.cr.usgs.gov/intranet/chem/labmethods.html#M8>.
    SGS Minerals Services, 1885 Leslie Street, Toronto, ON M3B 2M3, Canada, 2011, Selenium (Se): SGS Analytical Contract Laboratory Method 10, , accessed January 12, 2011 at <http://minerals.cr.usgs.gov/intranet/chem/labmethods.html#M10>.
    SGS Minerals Services, 1885 Leslie Street, Toronto, ON M3B 2M3, Canada, 2011, Total Carbon: SGS Analytical Contract Laboratory Method 3-A, , accessed January 12, 2011 at <http://minerals.cr.usgs.gov/intranet/chem/labmethods.html#M3a>.
    SGS Minerals Services, 1885 Leslie Street, Toronto, ON M3B 2M3, Canada, 2011, Forty-six elements are determined in a proprietary mobile metal ion leachates of solids by inductively coupled plasma-mass spectroscopy: SGS analytical method accessed January 12, 2011 at <http://www.geochem.sgs.com/mmi.htm>.
    Skyline Assayers & Laboratories, 1775 W Sahuaro Drive, P.O. Box 85670, Tucson, AZ 85754-5670, 2011, Sixty-nine constituents are determined in a proprietary enhanced enzyme leachates of solids by inductively coupled plasma-mass spectroscopy: Skyline analytic method SLE-1, p. 8, accessed January 12, 2011 at <http://www.skylinelab.com/docs/Skyline_Labs-2010_Schedule_of_Services_and_Fees-20091229-EN-WEB.pdf>.
    Skyline Assayers & Laboratories, 1775 W Sahuaro Drive, P.O. Box 85670, Tucson, AZ 85754-5670, 2011, Sixty-seven constituents in proprietary TerraSol leachates of solids by inductively coupled plasma-mass spectroscopy: Skyline analytic method SLE-3, p. 8, accessed January 12, 2011 at <http://www.skylinelab.com/docs/Skyline_Labs-2010_Schedule_of_Services_and_Fees-20091229-EN-WEB.pdf>.
    Taylor, Cliff D., Theodorakos, Peter M., and Peacock, Thomas R., 2002, Sample Preparation, in Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey: U.S. Geological Survey open-file report 02-223, p. A2-1 - A3-4, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/A1RxSampPrep_M.pdf>.
    Theodorakos, Peter M., 2002, Colorometric determination of ferrous iron, Fe(II), in natural water, wastewater, and seawater, in Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey: U.S. Geological Survey open-file report 02-223, p. W1-W2, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/W11Fe(II>)Hach_M.pdf.
    Theodorakos, Peter M., 2002, Conductivity measured using a self contained Digital Meter, in Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey: U.S. Geological Survey open-file report 02-223, p. D1-D2, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/D28Cond_M.pdf>.
    Theodorakos, Peter M., 2002, Determination of Total Alkalinity using a preset endpoint (pH 4.5) Autotitration System, in Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey: U.S. Geological Survey open-file report 02-223, p. E1-E3, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/E04PresetEndpoint_M.pdf>.
    Theodorakos, Peter M., 2002, Fluoride, chloride, nitrate, and sulfate in aqueous solution utilizing AutoSuppression chemically suppressed ion chromatography: U.S. Geological Survey open-file report 02-223, p. V1-V7, accessed January 12, 2011 at <http://pubs.usgs.gov/of/2002/ofr-02-0223/OFR-02-0223.pdf>.
    US EPA, Dissolved organic carbon in water is determined by a Shimadzu 5000A carbon analyzer using an infrared detector: US EPA SW-846 Method 9060A: Total Organic Carbon, 08-04-2008, accessed January 12, 2011 at <http://www.epa.gov/wastes/hazard/testmethods/sw846/pdfs/9060a.pdf>.

  5. How consistent are the relationships among the observations, including topology?

    Data have been analyzed using uniform documented techniques. For some elements, the methods of chemical analysis were the same throughout the study, while for others, the methods changed as analytical technology improved. Some of the methods used were specifically designed to give a concentration value based on a partial digestion or extraction of the sample. For these methods elements tightly bound in the structure of silicates in the sample are not measured. Therefore, the analytical results from these partial extraction techniques may not be comparable with results from methods designed to measure the total concentration of an element in a sample.


How can someone get a copy of the data set?

Are there legal restrictions on access or use of the data?

Access_Constraints: none
Use_Constraints:
none

  1. Who distributes the data set? (Distributor 1 of 1)

    Matthew Granitto
    U.S. Geological Survey
    Box 25046; Denver Federal Center, MS 973
    Denver, Colorado 80225
    United States of America

    1-303-236-1412 (voice)
    1-303-236-3200 (FAX)
    granitto@usgs.gov

  2. What's the catalog number I need to order this data set?

  3. What legal disclaimers am I supposed to read?

    These data are released on the condition that neither the U.S. Geological Survey (USGS) nor the United States Government may be held liable for any damages resulting from authorized or unauthorized use. The USGS provides these data "as is" and makes no guarantee or warranty concerning the accuracy of information contained in the data. The USGS further makes no warranties, either expressed or implied as to any other matter, whatsoever, including, without limitation, the condition of the product, or its fitness for any particular purpose. The burden for determining fitness for use lies entirely with the user.

  4. How can I download or order the data?


Who wrote the metadata?

Dates:
Last modified: 14-Dec-2009
Metadata author:
Matthew Granitto
U.S. Geological Survey
Box 25046, Denver Federal Center, MS 973
Denver, Colorado 80225
United States of America

1-303-236-1412 (voice)
1-303-236-3200 (FAX)
granitto@usgs.gov

Metadata standard:
FGDC Content Standards for Digital Geospatial Metadata (FGDC-STD-001-1998)