Link to USGS home page.

Table 3. Differences of precipitation measurements between the Belfort Universal Precipitation Gage 5-780, OTT PLUVIO Precipitation Gage, and the NovaLynx Model 260-2510 Standard Rain and Snow Gage, using the paired t-test and Wilcoxon signed-rank test at sites IL11, for 63 comparisons and PA15 for 64 comparisons.

[Abbreviations: --, no data; Belfort, Belfort Universal Precipitation Gage 5-780; OP, OTT PLUVIO precipitation gage; NovaLynx, NovaLynx Model 260-2510 Standard Rain and Snow Gage.]


Gage and site Mean precipitation (inches) Median precipitation (inches) Total precipitation (inches) Paired t-test Wilcoxon signed-rank test


Mean difference p-value Mean difference equals zero p-value Median difference equals zero
Belfort,
IL11
0.28 0.06 17.33 0.037 ~0 Reject ~0 Reject
OP,
IL11 East
0.33 0.07 20.93 0.305 ~0 Reject 0.112 Do not
reject
OP,
IL11 West
0.33 0.11 20.58 -0.015 0.002 Reject 0.078 Do not
reject
NovaLynx,
IL11
0.32 0.08 19.66 -- -- -- -- --
Belfort,
PA15
0.37 0.19 23.94 -0.011 0.026 Reject 0.003 Reject
OP,
PA15
0.38 0.20 24.49 -0.003 0.661 Do not
reject
0.203 Do not
reject
NovaLynx,
PA15
0.38 0.20 24.69 -- -- -- -- --

Return to FS 077-03 Report or Home.


For more information about USGS activities in Nevada, visit the USGS Nevada District home page.



FirstGov button  Take Pride in America button