Impedance file format

 The Z_file is an ASCII file containing the results of impedance calculations performed on the X and Y files bearing the same root file name and extension. The results are ordered by frequency and the values for each frequency occupy 2 lines with a total of 15 values per frequency. Each value is 11 characters long. An example of the format of data for a single frequency is:

11.2

0.5841

257

25.7

0.5052

168

43.5

 

153.379

34.161

11.034

-215.523

10.252

-129.447

-164.482

-86.834

 The impedance variables are listed by column number in the table below.

 

Column

 Line 1

 Line 2

1

Frequency in Hz

re Zxx

2

ExHy coherency

im Zxx

3

ExHy scalar apparent resistivity

re Zxy

4

ExHy scalar phase

im Zxy

5

EyHz coherency

re Zyx

6

EyHx scalar apparent resistivity

im Zyx

7

EyHx scalar phase

re Zyy

8

<blank>

im Zyy

 