|
U.S. Geological Survey Open-File Report 2004-1350 |
Table 2.2 - Method for ultratrace elemental analyses
A 0.5 g sample is digested in aqua regia at 90°C in a microprocessor controlled digestion box for 2 hours. The solution is diluted and analyzed by ICP/MS using a Perkin Elmer SCIEX ELAN 6100. International certified reference materials USGS GXR-1, GXR-2, GXR-4 and GXR-6 are analyzed at the beginning and end of each batch of samples. Internal control standards are analyzed every 10 samples and a duplicate is run for every 10 samples.
Code Ultratrace-1 Elements and Detection Limits (ppm) |
Element |
Detection Limit |
Upper Limit |
Au* |
0.2 ppb |
20,000 ppb |
Ag* |
0.05 |
200 |
Cu |
0.1 |
10,000 |
Cd |
0.1 |
200 |
Mn* |
1 |
10,000 |
Mo |
0.01 |
1,000 |
Pb* |
0.01 |
1,000 |
Ni* |
0.1 |
5,000 |
Zn* |
0.1 |
10,000 |
As* |
0.1 |
10,000 |
B* |
1 |
5,000 |
Ba* |
0.5 |
6,000 |
Sb |
0.02 |
500 |
W* |
0.2 |
200 |
Al* |
0.01% |
10% |
Be* |
0.1 |
1,000 |
Bi |
0.02 |
2,000 |
Ca* |
0.01% |
50% |
Ce* |
0.01 |
200 |
Co |
0.1 |
500 |
Cr* |
0.5 |
500 |
Cs* |
0.1 |
100 |
Eu* |
0.1 |
100 |
Fe* |
0.01% |
50% |
Ga* |
0.02 |
500 |
Ge* |
0.1 |
500 |
Hf* |
0.1 |
500 |
In |
0.02 |
100 |
K* |
0.01% |
5 |
La* |
0.5 |
200 |
Li |
0.5 |
1,000 |
Lu* |
0.1 |
100 |
Mg* |
0.01% |
10% |
Na* |
0.001% |
1% |
Nb* |
0.1 |
500 |
Nd* |
0.1 |
200 |
Rb* |
0.1 |
500 |
Re |
0.001 |
100 |
Se |
0.1 |
1,000 |
Sm* |
0.1 |
100 |
Sn* |
0.05 |
200 |
Sr* |
0.5 |
1,000 |
Ta* |
0.05 |
50 |
Tb* |
0.1 |
100 |
Te |
0.02 |
500 |
Th* |
0.1 |
200 |
Tl* |
0.02 |
500 |
U* |
0.1 |
200 |
V* |
1 |
1,000 |
Y* |
0.1 |
500 |
Yb* |
0.1 |
200 |
Zr* |
0.1 |
5,000 |
0.5 g of sample is digested with aqua regia (0.5 ml H20, 0.6 ml concentrated HNO3 and 1.8 ml concentrated HCl) for 2 hours at 95°C. Sample is cooled then diluted to 10 ml with deionized water and homogenized. The samples are then analyzed using a Perkin Elmer OPTIMA 3000 Radial ICP for the 37 element suite. A matrix standard and blank are run every 13 samples.
A series of USGS-geochemical standards are used as controls. This digestion is near total for base metals however will only be partial for silicates and oxides.
Code 1E2 Elements and Detection Limits (ppm) |
Element |
Detection Limit |
Upper Limit |
Ag* |
0.1 |
100 |
Al* |
0.01% |
|
As* |
3 |
|
B* |
5 |
|
Ba* |
1 |
|
Be* |
1 |
|
Bi* |
2 |
|
Ca* |
0.01% |
|
Cd |
0.2 |
2,000 |
Co* |
1 |
|
Cr* |
2 |
|
Cu |
1 |
10,000 |
Fe* |
0.01% |
|
Hg |
1 |
|
K* |
0.01% |
|
La* |
1 |
|
Mg* |
0.01% |
|
Mn* |
1 |
10,000 |
Mo* |
2 |
10,000 |
Na* |
0.001% |
|
Ni* |
1 |
10,000 |
P* |
0.001% |
|
Pb* |
2 |
5,000 |
S* |
0.001% |
20% |
Sb* |
5 |
|
Sc* |
0.1 |
|
Sn* |
5 |
|
Sr* |
1 |
|
Te* |
1 |
|
Ti* |
0.01% |
|
Tl* |
2 |
|
V* |
1 |
|
W* |
1 |
|
Y* |
1 |
|
Zn* |
1 |
10,000 |
Zr* |
1 |
|