Skip Links

USGS - science for a changing world

Open-File Report 2008–1358

Analytical Results for Municipal Biosolids Samples from a Monitoring Program near Deer Trail, Colorado (U.S.A.), 2007

By J.G. Crock, D.B. Smith, T.J.B. Yager, C.J. Berry, and M.G. Adams

Abstract

Thumbnail of and link to report PDF (2.2 MB)

Since late 1993, the Metro Wastewater Reclamation District of Denver (Metro District), a large wastewater treatment plant in Denver, Colorado, has applied Grade I, Class B biosolids to about 52,000 acres of nonirrigated farmland and rangeland near Deer Trail, Colorado (U.S.A.). In cooperation with the Metro District in 1993, the U.S. Geological Survey (USGS) began monitoring ground water at part of this site. In 1999, the USGS began a more comprehensive monitoring study of the entire site to address stakeholder concerns about the potential chemical effects of biosolids applications to water, soil, and vegetation. This more comprehensive monitoring program recently has been extended through 2010. Monitoring components of the more comprehensive study include biosolids collected at the wastewater treatment plant, soil, crops, dust, alluvial and bedrock ground water, and streambed sediment. Streams at the site are dry most of the year, so samples of streambed sediment deposited after rain were used to indicate surface-water effects. This report will present only analytical results for the biosolids samples collected at the Metro District wastewater treatment plant in Denver and analyzed during 2007. We have presented earlier a compilation of analytical results for the biosolids samples collected and analyzed for 1999 through 2006. More information about the other monitoring components is presented elsewhere in the literature. Priority parameters for biosolids identified by the stakeholders and also regulated by Colorado when used as an agricultural soil amendment include the total concentrations of nine trace elements (arsenic, cadmium, copper, lead, mercury, molybdenum, nickel, selenium, and zinc), plutonium isotopes, and gross alpha and beta activity. Nitrogen and chromium also were priority parameters for ground water and sediment components.

In general, the objective of each component of the study was to determine whether concentrations of priority parameters (1) were higher than regulatory limits, (2) were increasing with time, or (3) were significantly higher in biosolids-applied areas than in a similar farmed area where biosolids were not applied.

Previous analytical results indicate that the elemental composition of the biosolids from the Denver plant was consistent during 1999–2006 and this consistency continues with the samples for 2007; total concentrations of regulated trace elements remained consistently lower than the regulatory limits for the entire monitoring period.

See Report PDF for full abstract.

Version 1.0

Posted December 2008

Part or all of this report is presented in Portable Document Format (PDF); the latest version of Adobe Reader or similar software is required to view it. Download the latest version of Adobe Reader, free of charge.


Suggested citation:

Crock, J.G., Smith, D.B., Yager, T.J.B., Berry, C.J., and Adams, M.G., 2008, Analytical results for municipal biosolids samples from a monitoring program near Deer Trail, Colorado (U.S.A.), 2007: U.S. Geological Survey Open-File Report 2008–1358, 35 p.



Contents

Abstract

Introduction

Methology

Discussion and Results

Acknowledgments

References Cited


Accessibility FOIA Privacy Policies and Notices

Take Pride in America home page. FirstGov button U.S. Department of the Interior | U.S. Geological Survey
URL: http://pubsdata.usgs.gov/pubs/of/2008/1358/index.html
Questions or Assistance: Contact USGS
Last modified: Wednesday, 07-Dec-2016 21:35:57 EST