Open-File Report 2011–1081
ABSTRACTSoil gas and soil were assessed for contaminants at the Patterson Anti-Tank Range at Fort Gordon, Georgia, from October 2009 to September 2010. The assessment included identifying and delineating organic contaminants present in soil-gas samplers from the area estimated to be the Patterson Anti-Tank Range and in the hyporheic zone and floodplain of Brier Creek. This assessment was conducted to provide environmental contamination data to Fort Gordon personnel pursuant to requirements for the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Soil-gas samplers in the hyporheic zone and floodplain of Brier Creek contained total petroleum hydrocarbons, benzene, octane, and pentadecane concentrations above method detection levels. All soil-gas samplers within the boundary of the Patterson Anti-Tank Range contained total petroleum hydrocarbons above the method detection level. The highest total petroleum hydrocarbon mass detected was 147.09 micrograms in a soil-gas sampler located near the middle of the site and near the remnants of a manmade earthen mound and trench. The highest toluene mass detected was 1.04 micrograms and was located in the center of the Patterson Anti-Tank Range and coincides with a manmade earthen mound. Some soil-gas samplers installed detected undecane masses greater than the method detection level of 0.04 microgram, with the highest detection of soil-gas undecane mass of 58.64 micrograms collected along the southern boundary of the site. Some soil-gas samplers were installed in areas of high-contaminant mass to assess for explosives and chemical agents. Explosives or chemical agents were not detected above their respective method detection levels for all soil-gas samplers installed. |
First posted May 5, 2011 For additional information contact: Part or all of this report is presented in Portable Document Format (PDF); the latest version of Adobe Reader or similar software is required to view it. Download the latest version of Adobe Reader, free of charge. |
Caldwell, A.W., Falls, W.F., Guimaraes, W.B., Ratliff, W.H., Wellborn, J.B., and Landmeyer, J.E., 2011, Assessment of soil-gas and soil contamination at the Patterson Anti-Tank Range, Fort Gordon, Georgia, 2009–2010: U.S. Geological Survey Open-File Report 2011–1081, 40 p.
Abstract
Introduction
Purpose and Scope
Description of the Study Area
Methods
Passive Hyporheic Zone and Floodplain Survey
Passive Soil-Gas Survey
Soil Samples
Results
Passive Hyporheic Zone and Floodplain Survey
Passive Soil-Gas Survey
Soil Samples
Summary
References Cited