  <dc:contributor>Brian J. Andraski</dc:contributor>
  <dc:contributor>Ryan E. Archibald</dc:contributor>
  <dc:creator>Patrick E. McGuire</dc:creator>
  <dc:date>2009</dc:date>
  <dc:description>&lt;div class="NLM_sec NLM_sec_level_1 hlFld-Abstract"&gt;&lt;p&gt;The design, construction, and performance analyses of a 6.1ha evapotranspiration (ET) landfill cover at the semiarid U.S. Army Fort Carson site, near Colorado Springs, Colo. are presented. Initial water-balance model simulations, using literature reported soil hydraulic data, aided selection of borrow-source soil type(s) that resulted in predictions of negligible annual drainage (⩽1mm∕year). Final construction design was based on refined water-balance simulations using laboratory determined soil hydraulic values from borrow area natural soil horizons that were described with USDA soil classification methods. Cover design components included a 122cm thick clay loam (USDA), compaction ⩽80% of the standard Proctor maximum dry density (dry bulk density ∼1.3Mg/m3), erosion control measures, top soil amended with biosolids, and seeding with native grasses. Favorable hydrologic performance for a 5year period was documented by lysimeter-measured and Richards’-based calculations of annual drainage that were all &amp;lt;0.4mm∕year. Water potential data suggest that ET removed water that infiltrated the cover and contributed to a persistent driving force for upward flow and removal of water from below the base of the cover.&lt;/p&gt;&lt;/div&gt;</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>10.1061/(ASCE)1090-0241(2009)135:3(316)</dc:identifier>
  <dc:language>en</dc:language>
  <dc:publisher>ASCE</dc:publisher>
  <dc:title>Case study of a full-scale evapotranspiration cover</dc:title>
  <dc:type>article</dc:type>