<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:contributor>Christa A. Kelleher</dc:contributor>
  <dc:contributor>Seth J. K. Mason</dc:contributor>
  <dc:contributor>Thorsten Wagener</dc:contributor>
  <dc:contributor>Neil McIntyre</dc:contributor>
  <dc:contributor>Brian L. McGlynn</dc:contributor>
  <dc:contributor>Robert L. Runkel</dc:contributor>
  <dc:contributor>Robert A. Payn</dc:contributor>
  <dc:creator>Adam S. Ward</dc:creator>
  <dc:date>2017</dc:date>
  <dc:description>&lt;p&gt;&lt;span&gt;Researchers and practitioners alike often need to understand and characterize how water and solutes move through a stream in terms of the relative importance of in-stream and near-stream storage and transport processes. In-channel and subsurface storage processes are highly variable in space and time and difficult to measure. Storage estimates are commonly obtained using transient-storage models (TSMs) of the experimentally obtained solute-tracer test data. The TSM equations represent key transport and storage processes with a suite of numerical parameters. Parameter values are estimated via inverse modeling, in which parameter values are iteratively changed until model simulations closely match observed solute-tracer data. Several investigators have shown that TSM parameter estimates can be highly uncertain. When this is the case, parameter values cannot be used reliably to interpret stream-reach functioning. However, authors of most TSM studies do not evaluate or report parameter certainty. Here, we present a software tool linked to the One-dimensional Transport with Inflow and Storage (OTIS) model that enables researchers to conduct uncertainty analyses via Monte-Carlo parameter sampling and to visualize uncertainty and sensitivity results. We demonstrate application of our tool to 2 case studies and compare our results to output obtained from more traditional implementation of the OTIS model. We conclude by suggesting best practices for transient-storage modeling and recommend that future applications of TSMs include assessments of parameter certainty to support comparisons and more reliable interpretations of transport processes.&lt;/span&gt;&lt;/p&gt;</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>10.1086/690444</dc:identifier>
  <dc:language>en</dc:language>
  <dc:publisher>University of Chicago Press</dc:publisher>
  <dc:title>A software tool to assess uncertainty in transient-storage model parameters using Monte Carlo simulations</dc:title>
  <dc:type>article</dc:type>
</oai_dc:dc>