  <dc:description>&lt;html&gt;&lt;body&gt;
&lt;p&gt;When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of dissolved gases. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected dissolved-gas and water-temperature data at eight monitoring stations on the lower Columbia River in Oregon and Washington in 2009. Significant findings from the data include:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;During the spill season of April through August 2009, hourly values of total dissolved gas (TDG) were occasionally larger than 115-percent saturation for the forebay stations (John Day navigation lock, The Dalles forebay, Bonneville forebay, and Camas). Hourly values of total dissolved gas were occasionally larger than 120-percent saturation for two tailwater stations (John Day Dam tailwater and Cascade Island).&lt;/li&gt;
&lt;li&gt;From mid- to late July to mid-September 2009, water temperatures were greater than 20°C (degrees Celsius) at seven stations on the lower Columbia River. According to the State of Oregon temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20°C; Washington regulations state that the 1-day maximum should not exceed 20°C as a result of human activities.&lt;/li&gt;
&lt;li&gt;All 96 laboratory checks of the TDG sensors with a certified pressure gage were within 0.4 percent saturation after 3 to 4 weeks of deployment in the river.&lt;/li&gt;
&lt;li&gt;All but 2 of the 73 in situ field checks of TDG sensors with a secondary standard were within ± (plus or minus) 1.0-percent saturation after 3-4 weeks of deployment in the river. All 74 of the field checks of barometric pressure were within ±2.0 millimeters of mercury of a secondary standard, and all 65 water-temperature field checks were within ±0.2°C. &lt;/li&gt;
&lt;li&gt;For the eight monitoring stations in water year 2009, a total of 99.2 percent of the TDG data were received in real time by the USGS satellite downlink and were within 1-percent saturation of the expected value on the basis of calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites. Data received from the individual stations ranged from 97.0 to 100.0 percent complete.&lt;/li&gt;
&lt;/ul&gt;&lt;/body&gt;&lt;/html&gt;</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>10.3133/ofr20091288</dc:identifier>
  <dc:language>en</dc:language>
  <dc:publisher>U.S. Geological Survey</dc:publisher>
  <dc:title>Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, water year 2009: Quality-assurance data and comparison to water-quality standards</dc:title>