  <dc:contributor>Michael A. Ivanoff</dc:contributor>
  <dc:creator>Lora K. Striker</dc:creator>
  <dc:date>1997</dc:date>
  <dc:description>This report provides the results of a detailed Level II analysis of scour potential at structure 
WALDTH00180022 on Town Highway 18 crossing Coles Brook also known as Joes 
Brook, Walden, Vermont (figures 1–8). A Level II study is a basic engineering analysis of 
the site, including a quantitative analysis of stream stability and scour (U.S. Department of 
Transportation, 1993). Results of a Level I scour investigation also are included in 
Appendix E of this report. A Level I investigation provides a qualitative geomorphic 
characterization of the study site. Information on the bridge, gleaned from Vermont Agency 
of Transportation (VTAOT) files, was compiled prior to conducting Level I and Level II 
analyses and is found in Appendix D.
The site is in the New England Upland section of the New England physiographic province 
in northeastern Vermont. The 12.5-mi&lt;sup&gt;2&lt;/sup&gt;
 drainage area is in a predominantly rural and 
forested basin. In the vicinity of the study site, the surface cover is predominantly forested 
while the downstream left bank is shrub and brushland.
In the study area, the Coles Brook has an incised, sinuous channel with a slope of 
approximately 0.004 ft/ft, an average channel top width of 54 ft and an average bank height 
of 4 ft. The channel bed material ranges from gravel to bedrock with a median grain size 
(D50) of 124.1 mm (0.407 ft). The D&lt;sub&gt;50&lt;/sub&gt; was taken from a pebble count in the downstream 
channel, because the upstream channel is primarily bedrock. The geomorphic assessment at 
the time of the Level I and Level II site visit on August 8, 1995, indicated that the reach was 
stable.
The Town Highway 18 crossing of the Coles Brook is a 46-ft-long, one-lane bridge 
consisting of one 44-foot steel-beam span with a wooden deck (Vermont Agency of 
Transportation, written communication, April 5, 1995). The opening length of the structure 
parallel to the bridge face is 41.4 ft. The bridge is supported by a vertical, concrete abutment 
with wingwalls on the left and by a vertical, stone abutment with stone wingwalls with a 
concrete cap on the right. The channel is skewed approximately 5 degrees to the opening 
while the computed opening-skew-to-roadway is 10 degrees. 
The only scour protection measure at the site was a stone wall along the upstream left bank 
and type-2 stone fill (less than 36 inches diameter) along the entire base length of the 
upstream left wingwall, left abutment, and downstream left wing wall. Additional details 
describing conditions at the site are included in the Level II Summary and Appendices D 
and E.
Scour depths and recommended rock rip-rap sizes were computed using the general 
guidelines described in Hydraulic Engineering Circular 18 (Richardson and others, 1995) 
for the 100-year and 500-year discharges. Total scour at a highway crossing is comprised of 
three components: 1) long-term streambed degradation; 2) contraction scour (due to 
accelerated flow caused by a reduction in flow area at a bridge) and; 3) local scour (caused 
by accelerated flow around piers and abutments). Total scour is the sum of the three 
components. Equations are available to compute depths for contraction and local scour and 
a summary of the results of these computations follows.
Contraction scour for all modelled flows was 0.0 ft. Abutment scour ranged from 6.4 to 7.9 
ft at the left abutment and from 11.8 to 14.9 ft at the right abutment. The worst-case 
abutment scour occurred at the 500-year discharge. Additional information on scour depths 
and depths to armoring are included in the section titled “Scour Results”. Scouredstreambed elevations, based on the calculated scour depths, are presented in tables 1 and 2. 
A cross-section of the scour computed at the bridge is presented in figure 8. Scour depths 
were calculated assuming an infinite depth of erosive material and a homogeneous particlesize distribution. 
It is generally accepted that the Froehlich equation (abutment scour) gives “excessively 
conservative estimates of scour depths” (Richardson and others, 1995, p. 47). Usually, 
computed scour depths are evaluated in combination with other information including (but 
not limited to) historical performance during flood events, the geomorphic stability 
assessment, existing scour protection measures, and the results of the hydraulic analyses. 
Therefore, scour depths adopted by VTAOT may differ from the computed values 
documented herein.</dc:description>