Skip to main content
U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Results

294 results.

Alternate formats: Download search results as RIS  |  CSV | TSV | Excel  |  RSS feed based on this search  |  JSON version of this page of results

Page 5, results 101 - 125

Show results on a map

Publication Extents

Not all publications have extents, not all extents are completely accurate
Flood magnitude and frequency of Franklin Pond tributary at the culvert on New Jersey Route 23, Franklin Borough, Sussex County, New Jersey
Thomas Barringer
1996, Open-File Report 96-327
Flood magnitude and frequency values are presented for Franklin Pond tributary at the culvert at milepost 32.2 of New Jersey Route 23, Franklin Borough, New Jersey. The values were determined by using the New Jersey Department of Environmental Protection Special Report 38 method. A description of the drainage-basin characteristics also...
Flood magnitude and frequency of Little Mantual Creek at the culvert at milepost 7.8 on New Jersey Route 44, and at the Conrail culvert 0.20 miles downstream, West Deptford Township, Gloucester County, New Jersey
Thomas Barringer
1996, Open-File Report 96-326
The magnitude and frequency of floods at Little Mantua Creek at the culvert on New Jersey Route 44 at milepost 7.8 and at the Conrail culvert 0.20 miles downstream, in West Deptford Township, New Jersey, were determined by using the New Jersey Department of Environmental Protection Special Report 38 method....
Flood magnitude and frequency of Main Ditch at the culvert on New Jersey Route 44 and at the Conrail culvert downstream, West Deptford Township, Gloucester County, New Jersey
Thomas Barringer
1996, Open-File Report 96-325
The magnitude and frequency of floods at Main Ditch at the culvert on New Jersey Route 44 at milepost 8.3 and at the Conrail culvert 0.21 miles downstream, in West Deptford Township, New Jersey, were determined by using the New Jersey Department of Environmental Protection Special Report 38 method. Flood-magnitude...
Flood magnitude and frequency of Little Timber Creek at the culvert on Interstate Route 295, Haddon Heights Township, Camden County, New Jersey
T. H. Barringer
1996, Open-File Report 96-321
The magnitude and frequency of floods at the Little Timber Creek at the culvert on Interstate 295, at milepost 28.9, in Haddon Heights Township, New Jersey, were determined by using the New Jersey Department of Environmental Protection Special Report 38 method. Flood-magnitude and -frequency estimates, as well as drainage-basin characteristics,...
Flood magnitude and frequency of Monongahela Brook at the culvert on New Jersey Route 41, Deptford Township, Gloucester County, New Jersey
Thomas Barringer
1996, Open-File Report 96-320
Flood magnitude and frequency of Monongahela Brook in Deptford Township, Gloucester County, New Jersey, were determined by using the rational method. Flood-magnitude and -frequency estimates, as well as drainage-basin characteristics, are included in this report. The 100-year-flood estimate is 80 cubic feet per second....
Computer model of Raritan River Basin water-supply system in central New Jersey
Paul Dunne, Gary D. Tasker
1996, Open-File Report 96-360
This report describes a computer model of the Raritan River Basin water-supply system in central New Jersey. The computer model provides a technical basis for evaluating the effects of alternative patterns of operation of the Raritan River Basin water-supply system during extended periods of below-average precipitation. The computer model is...
Use of an ultra-clean sampling technique with inductively coupled plasma-mass spectrometry to determine trace-element concentrations in water from the Kirkwood-Cohansey Aquifer system, coastal plain, New Jersey
Tamara Ivahnenko, Zoltan Szabo, G.S. Hall
1996, Open-File Report 96-142
Water samples were collected during 1993 from 22 public supply wells screened in the Kirkwood-Cohansey aquifer system; concentrations of 18 trace elements were determined primarily by using inductively coupled plasma-mass spectrometry (ICP-MS) techniques, though graphite furnace atomic adsorption, hydride generation, and cold- vapor flameless atomic adsorption techniques were used for...
Reconnaissance of volatile organic compounds in the subsurface at Rutgers University, Busch Campus, Piscataway Township, New Jersey
Vincent T. DePaul
1996, Open-File Report 95-729
During 1991-92, the U.S. Geological Survey conducted a hydrogeologic reconnaissance at a site near the Rutgers University, Busch Campus, Chemical Engineering building, C-Wing. Results of analyses of the soil-gas samples, which were collected at 43 locations, indicated the presence of volatile organic compounds, primarily carbon tetrachloride, near the C-Wing building...