Scientific Investigations Report 2007–5216
U.S. GEOLOGICAL SURVEY
Scientific Investigations Report 2007–5216
Table 5. Results of test scenarios using thin-walled packaging collection bags.
[cm, centimeter; mL, milliliter]
Test number |
Seepage meter |
Test scenario description |
Test scenario |
Measured vertical flux rate (cm/day) |
Known test tank vertical flux (cm/day) |
Percent difference |
---|---|---|---|---|---|---|
9 | Large | 0 initial volume, tubing filled | 1 | 23.0 | 18.2 | 26.4 |
Large | 0 initial volume, tubing filled | 1 | 22.5 | 18.2 | 23.6 | |
Small | 0 initial volume, tubing filled | 1 | 15.2 | 18.2 | 16.5 | |
Small | 0 initial volume, tubing filled | 1 | 15.1 | 18.2 | 17.0 | |
10 | Large | 50 mL initial volume, tubing filled | 2 | 19.5 | 18.2 | 7.1 |
Large | 50 mL initial volume, tubing not filled | 3 | 21.4 | 18.2 | 17.6 | |
Small | 50 mL initial volume, tubing filled | 2 | 16.7 | 18.2 | 8.2 | |
Small | 50 mL initial volume, tubing not filled | 3 | 11.6 | 18.2 | 36.3 | |
11 | Large | 50 mL initial volume, tubing filled | 2 | 4.5 | 4.8 | 6.3 |
Large | 50 mL initial volume, tubing not filled | 3 | 7.4 | 4.8 | 54.2 | |
Small | 50 mL initial volume, tubing filled | 2 | 4.9 | 4.8 | 2.1 | |
Small | 50 mL initial volume, tubing not filled | 3 | 1.8 | 4.8 | 62.5 | |
12 | Large | 0 initial volume, empty tubing | 4 | 13.8 | 5.2 | 165 |
Large | 0 initial volume, empty tubing | 4 | 13.9 | 5.2 | 167 | |
Small | 0 initial volume, empty tubing | 4 | 1.9 | 5.2 | 63.5 | |
Small | 0 initial volume, empty tubing | 4 | 2.5 | 5.2 | 51.9 |