Scientific Investigations Report 2011–5153
AbstractProper interpretation of water quality requires consideration of the effects that contamination bias and sampling variability might have on measured analyte concentrations. The effect of contamination bias and sampling variability on major ion and total dissolved solids data in water samples collected in 48 of the 52 National Water-Quality Assessment Program study units from 1992–2010 is discussed in this report. Contamination bias and sampling variability can occur as a result of sample collection, processing, shipping, and analysis. Contamination bias can adversely affect interpretation of measured concentrations in comparison to standards or criteria. Sampling variability can help determine the reproducibility of an individual measurement or whether two measurements are different. Field blank samples help determine the frequency and magnitude of contamination bias, and replicate samples help determine the sampling variability (error) of measured analyte concentrations. Quality control data were evaluated for calcium, magnesium, sodium, potassium, chloride, sulfate, fluoride, silica, and total dissolved solids. A 99-percent upper confidence limit is calculated from field blanks to assess the potential for contamination bias. For magnesium, potassium, chloride, sulfate, and fluoride, potential contamination in more than 95 percent of environmental samples is less than or equal to the common maximum reporting level. Contamination bias has little effect on measured concentrations greater than 4.74 mg/L (milligrams per liter) for calcium, 14.98 mg/L for silica, 4.9 mg/L for sodium, and 120 mg/L for total dissolved solids. Estimates of sampling variability are calculated for high and low ranges of concentration for major ions and total dissolved solids. Examples showing the calculation of confidence intervals and how to determine whether measured differences between two water samples are significant are presented. |
First posted February 7, 2012 For additional information contact: Part or all of this report is presented in Portable Document Format (PDF); the latest version of Adobe Reader or similar software is required to view it. Download the latest version of Adobe Reader, free of charge. |
Gross, E.L., Lindsey, B.D., and Rupert, M.G., 2012, Quality of major ion and total dissolved solids data from groundwater sampled by the National Water-Quality Assessment Program, 1992–2010: U.S. Geological Survey Scientific Investigations Report 2011–5153, 26 p.
Abstract
Introduction
Purpose and Scope
Environmental and Quality-Control Data
Types of Quality-Control Samples
Compilation of Data
Methods of Data Analysis
Methods Used to Determine Contamination Bias
Methods Used to Determine Sampling Variability
Quality of Major Ion and Total Dissolved Solids Data
Contamination Bias
Sampling Variability
Trends in Sampling Variability
Confidence Intervals
Implications for Interpreting Environmental Data
Potential Effects of Contamination Bias
Potential Effects of Sampling Variability
Summary
Acknowledgments
References Cited