WRIR 00-4014
Quality Assurance and Analysis of Water Levels in Wells on Pahute Mesa and Vicinity, Nevada Test Site


CONTENTS

Abstract
Introduction
Water-Level Measurements
Sources of Water-Level Fluctuations
Analysis of Water Levels

Summary
References Cited
Appendix 1
Appendix 2

Appendix 2. Water-level measurements for selected wells on Pahute Mesa and vicinity, Nevada Test Site, 1963-98

Method used to determine depth to water: L, interpreted from geophysical log; R, reported, method not known; S, calibrated steel-tape measurement; T, calibrated electric tape; V, calibrated electric cable (wire line or iron horse).

Quality-assurance flag: A, anomalous value; AT, water level does not agree with second access tube in same open interval; C, affected by  well construction, queried where uncertain; D, dry hole; H or L, static water level in well is elevated above (H) or depressed below (L) regional ground-water level; R, well pumping or recently pumped; N, water level affected by nuclear test; X, water level corrected for borehole deviation; --, no flag applied

Water above bottom of open interval: length of water column in well from top of water to bottom of open interval listed in table 1.

USGS
well name
USGS site identification
number
Water-level measurement Water above
bottom of
open interval
(feet)
Date Depth below
land surface
(feet)
Altitude
(feet above
sea level)
Method Quality-
assurance
flag
U -20ar 1 371852116281701 02-09-1987 1,836.8 4,482 V -- 448
    03-10-1987 1,841.2 4,478 V -- 444
    03-16-1987 1,842.6 4,476 V -- 442
    03-24-1987 1,843.6 4,475 V -- 441
    03-25-1987 1,842.4 4,477 V -- 443
 
    03-31-1987 1,843.3 4,476 V -- 442
    04-07-1987 1,840.9 4,478 V -- 444
    05-04-1987 1,845.6 4,473 V -- 439
    05-08-1987 1,841.0 4,478 V -- 444

Table of Contents
USGS Water home page || USGS home page 

The pathname for this page is <app2_u20ar1.htm> 
These pages are maintained by S.C. DeMeo <email: scdemeo@usgs.gov> 
Last modified: Tuesday, July 18, 2000