CONTENTS
Abstract
Introduction
Water-Level Measurements
Sources of Water-Level Fluctuations
Analysis of Water Levels
Summary
References Cited
Appendix
1
Appendix 2
|
Appendix 2. Water-level
measurements for selected wells on Pahute Mesa and vicinity, Nevada
Test Site, 1963-98
Method used to determine depth to
water: L, interpreted from geophysical log; R, reported, method
not known; S, calibrated steel-tape measurement; T, calibrated
electric tape; V, calibrated electric cable (wire line or iron horse).
Quality-assurance flag: A, anomalous value; AT, water level
does not agree with second access tube in same open interval; C,
affected by well construction, queried where uncertain; D, dry
hole; H or L, static water level in well is elevated above (H) or
depressed below (L) regional ground-water level; R, well pumping or
recently pumped; N, water level affected by nuclear test; X, water
level corrected for borehole deviation; --, no flag applied
Water above bottom of open interval: length of water column in
well from top of water to bottom of open interval listed in table
1.
USGS
well
name
|
USGS site
identification
number
|
Water-level
measurement
|
Water
above
bottom of
open interval
(feet)
|
Date
|
Depth below
land surface
(feet)
|
Altitude
(feet above
sea level)
|
Method
|
Quality-assurance
flag
|
U -20av |
371359116252301 |
08-04-1986 |
2,080.0 |
4,384 |
V |
-- |
20 |
|
|
08-05-1986 |
2,080.1 |
4,384 |
V |
-- |
20 |
|
|
08-07-1986 |
2,079.9 |
4,384 |
V |
-- |
20 |
|
|
08-15-1986 |
2,080.1 |
4,384 |
V |
-- |
20 |
|
|
10-07-1986 |
2,073 |
4,391 |
L |
-- |
27 |
|
|
12-08-1986 |
2,075.5 |
4,389 |
V |
-- |
25 |
|