WRIR 00-4014
Quality Assurance and Analysis of Water Levels in Wells on Pahute Mesa and Vicinity, Nevada Test Site


CONTENTS

Abstract
Introduction
Water-Level Measurements
Sources of Water-Level Fluctuations
Analysis of Water Levels

Summary
References Cited
Appendix 1
Appendix 2

Appendix 2. Water-level measurements for selected wells on Pahute Mesa and vicinity, Nevada Test Site, 1963-98

Method used to determine depth to water: L, interpreted from geophysical log; R, reported, method not known; S, calibrated steel-tape measurement; T, calibrated electric tape; V, calibrated electric cable (wire line or iron horse).

Quality-assurance flag: A, anomalous value; AT, water level does not agree with second access tube in same open interval; C, affected by  well construction, queried where uncertain; D, dry hole; H or L, static water level in well is elevated above (H) or depressed below (L) regional ground-water level; R, well pumping or recently pumped; N, water level affected by nuclear test; X, water level corrected for borehole deviation; --, no flag applied

Water above bottom of open interval: length of water column in well from top of water to bottom of open interval listed in table 1.

USGS
well name

USGS site identification
number

Water-level measurement

Water above
bottom of
open interval
(feet)

Date

Depth below
land surface
(feet)

Altitude
(feet above
sea level)

Method

Quality-
assurance
flag

U -20y 371315116282701 12-18-1974 2,068 4,189 L -- 534
    12-26-1974 2,068 4,189 L -- 534
    01-04-1975 2,069 4,188 L -- 533
    01-09-1975 2,064 4,193 L -- 538
    01-17-1975 2,066 4,191 L -- 536
 
    01-21-1975 2,073 4,184 L -- 529
    02-01-1975 2,067 4,190 L -- 535
    02-07-1975 2,066 4,191 L -- 536
    02-18-1975 2,067 4,190 L -- 535

Table of Contents
USGS Water home page || USGS home page 

The pathname for this page is <app2_u20y.htm> 
These pages are maintained by S.C. DeMeo <email: scdemeo@usgs.gov> 