Table 4. Distribution of underground tests relative to water table and estimated number of tests that have introduced test-generated contaminants into the ground-water flow system by major test area at the Nevada Test Site

[Working point is depth at which nuclear device is detonated; water table is estimated or measured altitude of regional water table prior to underground test; cavity radius (CR) is estimated or measured radius of cavity formed after underground test (typically determined by post-shot drilling as distance between working point and lower surface of the radioactive glass "puddle" formed in bottom of cavity). Source is U.S. Department of Energy (1994). Calculations based on measurements of cavity radius, and on working-point and static borehole water-level depths, as summarized in classified listing of test parameters (Lawrence Livermore National Laboratory, written commun., 1991).]
 

NTS area (figure 2) Number of underground tests
Location of working point relative to water table Tests that introduced contaminats into the ground-water flow system
Below Above
Less than or equal to CR Greater than one and less than or equal to two CR Greater than two and less than or equal to five CR1 Greater than five CR Certain or probable2 Maximum3 Total4
Yucca Flat
1
2
3
4
6
0
19
9
16
0
0
10
5
3
0
0
6
12
2
0
0
21
43
5
1
3
81
183
8
4
0
35
26
21
0
0
56
69
26
1
3
137
252
34
5
7
8
9
10
15
30
0
1
1
0
8
1
2
2
0
8
0
1
2
0
6
1
5
6
6
10
8
90
45
0
46
1
4
5
3
52
2
9
11
0
62
10
99
56
3
Subtotal 76 31 31 88 435 138 226 661
Pahute Mesa
19
20
14
20
15
22
3
3
2
1
2
3
32
45
34
46
36
49
Subtotal 34 37 6 3 5 77 80 85
Rainier Mesa
12 0 0 0 0 62 0 0 62
Frenchman Flat
5
11
1
0
2
1
1
1
1
3
0
0
4
2
5
5
5
5
Subtotal 1 3 2 4 0 6 10 10
Shoshone Mesa
16 0 0 0 0 6 0 0 6
Buckboard Mesa
18 0 0 0 0 3 0 0 3
Dome Mountain
30 0 0 0 0 1 0 0 1
Total 111 71 39 95 512 221 316 828

1 Zone includes region of widespread fracturing caused by detonation.

 2 Category defined as tests that certainly or probably have introduced test-generated contaminants directly into ground-water flow system; includes all tests detonated below water table and detonated above but within two cavity radii of water table.

 3 Category defined as the maximum number of tests (includes certain or probable category) likely to have introduced test-generated contaminants into ground-water flow system; includes all tests detonated below water table and detonated above but within five cavity radii of water table.

 4 Category includes all underground (and shallow cratering) tests. Number of tests is less than total number of detonations at Nevada Test Site because some tests include multiple detonations (U.S. Department of Energy, 1994).



Return to WRIR 96-4109||Return to the Index||Go to WRIR 96-4109 Plates

USGS Water home page || USGS home page

The pathname for this page is <table4.htm>
These pages are maintained by S.C. DeMeo
Last modified Wednesday, 07-Dec-2016 12:41:14 EST