Abstract

Peltier coolers were modified and calibrated to serve as soil heat flux transducers. The modification was to fill their interiors with epoxy. The average calibration constant on 21 units was 13.6 ± 0.8 kW m−2 V−1 at 20°C. This sensitivity is about eight times that of the two thermopile transducers with which comparisons were made. The temperature coefficients of the Peltier cooler transducers avg −0.034 kW m−2 V−1 °C−1, whereas those of the two thermopile transducers were only 25% as large, relative to their calibration constants. The thermal conductivity of the Peltier cooler transducers was 0.4 W m−1 °C−1, which is comparable to that of dry soil. The cost of an unmodified Peltier cooler is around 20 dollars.

Publication type Article
Publication Subtype Journal Article
Title Use of Peltier coolers as soil heat flux transducers
Series title Soil Science Society of America Journal
DOI 10.2136/sssaj1985.03615995004900040054x
Volume 49
Issue 4
Year Published 1985
Language English
Publisher Wiley
Description 3 p.
First page 1065
Last page 1067