The U.S. Geological Survey in cooperation with the U.S. Army Corps of Engineers, Chicago District did field-scale tests in August-September 1996 to determine mixing patterns associated with different configurations of coarse-bubble air diffusers. The tests were done in an approximately 13-meter deep quarry near Chicago, Ill. Three-dimensional velocity, water-temperature, dissolved oxygen concentration, and specific-conductivity profiles were collected from locations between approximately 2 to 30 meters from the diffusers for two sets of five test configurations; one set for stratified and one set for destratified conditions in the quarry. The data-collection methods and instrumentation used to characterize mixing patterns and interactions of coarse-bubble diffusers were successful. An extensive data set was collected and is available to calibrate and verify aeration and stratification models, and to characterize basic features of bubble-plume interaction.