The evaluation of uncertainty in low-flow data collected from three streamflow-gaging stations on the upper Verde River, Arizona, was presented. In downstream order, the stations are Verde River near Paulden, Verde River near Clarkdale, and Verde River near Camp Verde. A monitoring objective of the evaluation was to characterize discharge of the lower flow regime through a variety of procedures such as frequency analysis and base-flow analysis. For Verde River near Paulden and near Camp Verde, the uncertainty of daily low flows can be reduced by decreasing the uncertainty of discharge-measurement frequency, or building an artificial control that would have a stable stage-discharge relation over time.