Evidence of CFC degradation in groundwater under pyrite-oxidizing conditions
Links
- More information: Publisher Index Page (via DOI)
- Download citation as: RIS | Dublin Core
Abstract
A detailed local-scale monitoring network was used to assess CFC distribution in an unconfined sand aquifer in southwestern Ontario where the zone of 1–5-year-old groundwater was known with certainty because of prior use of a bromide tracer. Groundwater ⩽5 years old was confined to an aerobic zone at ⩽5 m depth and had CFC concentrations consistent with modern atmospheric mixing ratios at recharge temperatures of 7–11 °C, as was observed in the 3-m thick vadose zone at the site. At depths below 6 m, the groundwater became progressively more reducing, however, with a denitrifying horizon at 6–7 m depth, and a Mn and Fe reducing zone below 7 m depth. In the anaerobic zone, 3H/3He ratios indicated that groundwater-age continued to increase uniformly with depth, to a maximum value of 27 years at 13 m depth. CFC concentrations, however, decreased abruptly within the denitrifying zone, leading to substantial age overestimation compared to the 3H/3He ages. Noble gas data indicated that the apparent CFC mass loss was not likely the result of gas stripping from possible bubble formation; thus, CFC degradation was indicated in the anoxic zone. The field data are consistent with first-order degradation rates of 0.3 yr−1 for CFC-12, 0.7 yr−1 for CFC-11, and 1.6 yr−1 for CFC-113. CFC attenuation at this site coincides with a zone where reduced S (pyrite) is actively oxidized by NO3 and dissolved oxygen (DO). Similar behavior has been observed at other sites [Tesoriero, A.J., Liebscher, H., Cox, S.E., 2000. Mechanism and rate of denitrification in an agricultural watershed: electron and mass balance along groundwater flow path. Water Resour. Res. 36 (6), 1545–1559; Hinsby, K., Hojberg, A.L., Engesgaard, P., Jensen, K.H., Larsen, F., Plummer, L.N., Busenberg, E., Accepted for publication. Transport and degradation of chlorofluorocarbons (CFCs) in a pyritic aquifer, Rabis Creek, Denmark. Water Resour. Res.], further demonstrating that the use of CFCs for age-dating anaerobic groundwater should be approached with caution, particularly if the sediment contains pyrite.
Suggested Citation
Sebol, L., Robertson, W., Busenberg, E., Plummer, N., Ryan, M., and Schiff, S., 2007, Evidence of CFC degradation in groundwater under pyrite-oxidizing conditions: Journal of Hydrology, v. 347, no. 1-2, p. 1-12, https://doi.org/10.1016/j.jhydrol.2007.08.009.
| Publication type | Article |
|---|---|
| Publication Subtype | Journal Article |
| Title | Evidence of CFC degradation in groundwater under pyrite-oxidizing conditions |
| Series title | Journal of Hydrology |
| DOI | 10.1016/j.jhydrol.2007.08.009 |
| Volume | 347 |
| Issue | 1-2 |
| Year Published | 2007 |
| Language | English |
| Publisher | Elsevier |
| Contributing office(s) | Toxic Substances Hydrology Program |
| Description | 12 p. |
| Larger Work Type | Article |
| Larger Work Subtype | Journal Article |
| Larger Work Title | Journal of Hydrology |
| First page | 1 |
| Last page | 12 |