Evidence of CFC degradation in groundwater under pyrite-oxidizing conditions
Links
- More information: Publisher Index Page (via DOI)
- Download citation as: RIS | Dublin Core
Abstract
A detailed local-scale monitoring network was used to assess CFC distribution in an unconfined sand aquifer in southwestern Ontario where the zone of 1–5-year-old groundwater was known with certainty because of prior use of a bromide tracer. Groundwater ⩽5 years old was confined to an aerobic zone at ⩽5 m depth and had CFC concentrations consistent with modern atmospheric mixing ratios at recharge temperatures of 7–11 °C, as was observed in the 3-m thick vadose zone at the site. At depths below 6 m, the groundwater became progressively more reducing, however, with a denitrifying horizon at 6–7 m depth, and a Mn and Fe reducing zone below 7 m depth. In the anaerobic zone, 3H/3He ratios indicated that groundwater-age continued to increase uniformly with depth, to a maximum value of 27 years at 13 m depth. CFC concentrations, however, decreased abruptly within the denitrifying zone, leading to substantial age overestimation compared to the 3H/3He ages. Noble gas data indicated that the apparent CFC mass loss was not likely the result of gas stripping from possible bubble formation; thus, CFC degradation was indicated in the anoxic zone. The field data are consistent with first-order degradation rates of 0.3 yr−1 for CFC-12, 0.7 yr−1 for CFC-11, and 1.6 yr−1 for CFC-113. CFC attenuation at this site coincides with a zone where reduced S (pyrite) is actively oxidized by NO3 and dissolved oxygen (DO). Similar behavior has been observed at other sites [Tesoriero, A.J., Liebscher, H., Cox, S.E., 2000. Mechanism and rate of denitrification in an agricultural watershed: electron and mass balance along groundwater flow path. Water Resour. Res. 36 (6), 1545–1559; Hinsby, K., Hojberg, A.L., Engesgaard, P., Jensen, K.H., Larsen, F., Plummer, L.N., Busenberg, E., Accepted for publication. Transport and degradation of chlorofluorocarbons (CFCs) in a pyritic aquifer, Rabis Creek, Denmark. Water Resour. Res.], further demonstrating that the use of CFCs for age-dating anaerobic groundwater should be approached with caution, particularly if the sediment contains pyrite.
Publication type | Article |
---|---|
Publication Subtype | Journal Article |
Title | Evidence of CFC degradation in groundwater under pyrite-oxidizing conditions |
Series title | Journal of Hydrology |
DOI | 10.1016/j.jhydrol.2007.08.009 |
Volume | 347 |
Issue | 1-2 |
Year Published | 2007 |
Language | English |
Publisher | Elsevier |
Contributing office(s) | Toxic Substances Hydrology Program |
Description | 12 p. |
Larger Work Type | Article |
Larger Work Subtype | Journal Article |
Larger Work Title | Journal of Hydrology |
First page | 1 |
Last page | 12 |
Google Analytic Metrics | Metrics page |