Determination of Antimycin-A in water by liquid chromatographic/mass spectrometry: single-laboratory validation
Links
- More information: Publisher Index Page (via DOI)
- Download citation as: RIS | Dublin Core
Abstract
An LC/MS method was developed and validated for the quantitative determination and confirmation of antimycin-A (ANT-A) in water from lakes or streams. Three different water sample volumes (25, 50, and 250 mL) were evaluated. ANT-A was stabilized in the field by immediately extracting it from water into anhydrous acetone using SPE. The stabilized concentrated samples were then transported to a laboratory and analyzed by LC/MS using negative electrospray ionization. The method was determined to have adequate accuracy (78 to 113% recovery), precision (0.77 to 7.5% RSD with samples ≥500 ng/L and 4.8 to 17% RSD with samples ≤100 ng/L), linearity, and robustness over an LOQ range from 8 to 51 600 ng/L.
Publication type | Article |
---|---|
Publication Subtype | Journal Article |
Title | Determination of Antimycin-A in water by liquid chromatographic/mass spectrometry: single-laboratory validation |
Series title | Journal of AOAC International |
DOI | 10.5740/jaoacint.12-286 |
Edition | 2 |
Volume | 96 |
Year Published | 2013 |
Language | English |
Publisher | Association of Analytical Communities (AOAC) International |
Contributing office(s) | Upper Midwest Environmental Sciences Center |
Description | 9 p. |
First page | 413 |
Last page | 421 |
Online Only (Y/N) | N |
Additional Online Files (Y/N) | N |
Google Analytic Metrics | Metrics page |