A method for adjusting values of Manning's roughness coefficient for flooded urban areas
Links
- Document: Report (17.16 MB pdf)
- Download citation as: RIS | Dublin Core
Abstract
A method is presented for adjusting values of Manning's roughness coefficient for flooded urban areas on the basis of the density of buildings on a flood plain and verified roughness coefficients for natural conditions. An urban roughness coefficient can be calculated to emulate the water-surface profiles to within 0.06 meter for depths of flow less than 0.6 meter and plus or minus 10 percent for depths between 0.6 and 2 meters.
Publication type | Article |
---|---|
Publication Subtype | Journal Article |
Title | A method for adjusting values of Manning's roughness coefficient for flooded urban areas |
Series title | Journal of Research of the U.S. Geological Survey |
Volume | 5 |
Issue | 5 |
Year Published | 1977 |
Language | English |
Publisher | U.S. Geological Survey |
Publisher location | Reston, VA |
Description | 5 p. |
First page | 541 |
Last page | 545 |
Online Only (Y/N) | N |
Additional Online Files (Y/N) | N |
Google Analytic Metrics | Metrics page |