Three-dimensional temperature maps of the Williston Basin, USA: Implications for deep hot sedimentary and enhanced geothermal resources

Geothermics
By:  and 

Links

Abstract

As part of U.S. Geological Survey's (USGS) efforts to identify and assess geothermal energy resources of the US, a three-dimensional (3D) geologic and thermal model has been constructed for the Williston Basin, USA. The geologic model consists of all sedimentary units above the Proterozoic and Archean crystalline rock (called basement herein), with a total sedimentary thickness of up to 5 km near the basin center. Twenty-nine geologic units were mapped from interpreted formation tops from 16,465 wells. A 3D temperature model was constructed to a depth of 7 km by constructing a 3D heat flow model for the sedimentary units, followed by estimating underlying temperature using a one-dimensional (1D) analytic solution for heat flow within the underlying crystalline basement. Using the sedimentary basin model, heat flow was simulated in 3D and was calibrated using three temperature datasets: 1) 24 high-confidence static temperature logs (equilibrium thermal profiles), 2) more than15,000 drill stem test (DST) measurements from >7,000 wells, and 3) more than 45,000 bottomhole temperature (BHT) measurements from >14,000 wells. The DST and BHT datasets provide broad spatial coverage, but are lower confidence, primarily because measurements were made prior to attaining thermal equilibrium. DST and BHT measurements were binned regionally to develop representative thermal profiles that generally agree with these lower quality data (hereafter called pseudowell temperature profiles). Layer properties (primarily thermal conductivity and compaction curves) were set to best estimate values, then the heat flow model was calibrated to fit pseudowell and static temperature logs primarily by adjusting basal heat flow to approximate the overall temperature profile. Minor adjustments to thermal conductivity allowed adjusting changes in slope at lithologic contacts. Resulting maps include 3D temperature and basal (bottom of sedimentary units) heat flow estimates, which are used as input for the temperature model of the basement. The crystalline basement temperature model uses an analytic 1D solution to the heat flow equation that requires estimates of heat flow and temperature at the upper boundary (i.e., the sediment/basement contact), radiogenic heat production within the crystalline basement, and reference thermal conductivity (i.e., uncorrected for temperature). Two regions of high heat flow are identified: 1) in western North Dakota along the North American Central Plains Conductivity Anomaly and 2) in eastern Montana near the Poplar dome. Within the sedimentary column in the center of the basin of the basin, an area of approximately 100,000 km2 is predicted to have moderate- to high-temperature geothermal resources (>90 °C) under the thickest sequences of sediments. Where thick insulation and high heat flow coincide, electric-grade resources can be less than 4 km deep. Assuming a maximum feasible drilling depth of 7 km, temperatures are predicted to be as high as 175 °C. The geologic model may be used to identify strata at sufficient temperatures that may have natural permeability or that may have conditions that favor development of enhanced/engineered geothermal systems resources.

Study Area

Publication type Article
Publication Subtype Journal Article
Title Three-dimensional temperature maps of the Williston Basin, USA: Implications for deep hot sedimentary and enhanced geothermal resources
Series title Geothermics
DOI 10.1016/j.geothermics.2024.103196
Volume 125
Year Published 2024
Language English
Publisher Elsevier
Contributing office(s) Central Energy Resources Science Center
Description 103196, 9 p.
Country United States
State Montana, North Dakota, South Dakota
Other Geospatial Williston Basin
Google Analytic Metrics Metrics page
Additional publication details