Analysis of picric acid in water by high-performance liquid chromatography
Links
- Document: Report (pdf)
- Download citation as: RIS | Dublin Core
Abstract
Methods for the determination of picric acid (2,4,6, trinitrophenol) in water employing high-performance liquid chromatography are presented. Ion-pair chromatography under an isocratic condition is performed on a reverse-phase column. Picric acid can be determined directly in water at a lower detection limit of 10 micrograms per liter. By use of an extraction procedure, detection down to 0.1 microgram per liter can be realized.
Publication type | Report |
---|---|
Publication Subtype | USGS Numbered Series |
Title | Analysis of picric acid in water by high-performance liquid chromatography |
Series title | Open-File Report |
Series number | 79-207 |
DOI | 10.3133/ofr79207 |
Year Published | 1979 |
Language | English |
Publisher | U.S. Geological Survey |
Description | iv, 7 p. |