Hydrologic testing was conducted at wells WIPP-25, WIPP-26, WIPP-27, WIPP-28, WIPP-29, and WIPP-30 in Nash Draw near the Waste Isolation Pilot Plant site in southeastern New Mexico. The three water-bearing zones tested were the Magenta Dolomite Member of the Rustler Formation, Culebra Dolomite Member of the Rustler Formation, and the Rustler Formation-Salado Formation contact zone. Inflatable packers were used in a variety of test configurations. Tests conducted include bailing, recovery after perforation, shut in, slug, flow, and pressure pulse. Water pressure response in the tested zone was monitored by a pressure-transducer system. Preliminary hydrologic-test data are tabulated in chronological order for each well. (Lantz-PTT)