Link to USGS Home Page

METHODS FOR SAMPLING AND INORGANIC ANALYSIS OF COAL
U.S. Geological Survey Bulletin 1823

Edited by D.W. Golightly and F.O. Simon


Table 19. Operating parameters: flame and graphite-furnace atomization

Element Wavelength
(nm)
Bandpass
(nm)
Background
Correction
Cella Matrix
Cd 228.8 0.7 Yes Graphite Furnace 0.5% ash solution; extract in 5% HCl
Cu 324.7 0.7 No Flame 1% ash solution in 5% HCl
Li 670.8 1.4 No Flame 1% ash solution in 5% HCl
Mg 285.2 0.7 No Flame 0.01% ash solution in 5% HCl
Mn 279.5 0.2 No Flame 1% ash solution in 5% HCl
Na 589.0 0.2 No Flame 0.1% ash solution in 5% HCl
Pb 217.0 0.7 Yes Flame 0.1% ash solution in 5% HCl
Zn 213.9 0.7 Yes Flame 1% ash solution in 5% HCl
aFlame: Fuel-lean air-acetylene.
Graphite furnace: 20--,uL sample, argon sheath gas, conventional graphite tube. Furnace sequence: (1) Dry for 20 s at 110° C. (2) Char for 25 s at 250° C. (3) Atomize for 5 s at 2,100° C with 1 s ramp to temperature. Interrupt gas flow (default to 50 mL/min with the model 2100 HGA).