Mira Catalina Elementary School

The data collected at Mira Catalina Elementary School are presented here. Figure 1 is a schematic of the school site that shows the rooms that were tested for indoor radon colored according to the amount of radon in the rooms. Figure 1 also show the approximate locations of the sites where field gamma-ray measurements were made. Table 1 lists the results of the field gamma-ray measurements. Samples of the top five inches of soil were collected and two of the gamma-ray sites and Table 2 lists the results of analyses of those samples. Table 3 lists the results of the indoor radon measurements.

 

Schematic of rooms at Soleado Elementary School with indoor radon and gamma-ray sites.

Figure 1. Schematic of rooms at Mira Catalina Elementary School showing indoor radon levels and sites at which gamma-ray measurements were made.

 

 

Table 1. Results of gamma-ray spectrometer measurements at Mira Catalina Elementary School. Site locations are indicated in Figure 1 (e.g. location number 1 refers to MCEP1). The column labeled "Group" identifies the group to which the measurement was assigned as a result of classification of the gamma-ray data.

 

Location

K

eU

eTh

Group

Latitude

Longitude

 

(%)

(ppm)

(ppm)

 

(degrees)

(degrees)

MCEP1

1.9

1.1

5.4

3

33.7406

-118.3339

MCEP2

1.6

1.5

5.4

3

33.7397

-118.3340

MCEP3

1.2

1.4

3.5

3

33.7401

-118.3340

MCEP4

1.6

1.8

4.6

3

33.7395

-118.3340

MCEP5

1.2

1.4

4.1

3

33.7394

-118.3342

MCEP6

1.1

1.2

3.3

3

33.7397

-118.3338

 

Table 2. Results of laboratory measurements of soil samples. The K, eU, and eTh concentrations were determined by a laboratory gamma-ray spectrometer and the field results are presented for comparison. Radon emanation fraction was determined as discussed in the section on methodologies.

 

Location

Laboratory

Field Spectrometer

Radon

Latitude

Longitude

 

K

eU

eTh

K

eU

eTh

Eman.

(degrees)

(degrees)

 

(%)

(ppm)

(ppm)

(%)

(ppm)

(ppm)

 

 

 

MCEP2

0.9

2.0

4.3

1.6

1.5

5.4

0.16

33.7397

-118.3340

MCEP5

1.0

2.0

4.1

1.2

1.4

4.1

0.25

33.7394

-118.3342

 

 

 

 

 

 

 

 

 

 

 

Bulk Density (g/cc)

Water Content

Porosity

 

 

 

MCEP2

0.96

17.7%

0.64

 

 

 

MCEP5

1.04

not determined

0.61

 

 

 

 

 

Table 3. Results of indoor radon measurements in classrooms.

 

Room

Radon

Start

Stop

Number

(pCi/L)

Date

Time

Date

Time

1

0.6

18-Apr-03

18:03

20-Apr-03

16:55

2

0.2

18-Apr-03

18:04

20-Apr-03

16:56

3

0.2

18-Apr-03

18:05

20-Apr-03

16:57

4

0.3

18-Apr-03

18:05

20-Apr-03

16:59

5

0.2

18-Apr-03

18:07

20-Apr-03

17:00

6

0.2

18-Apr-03

18:08

20-Apr-03

17:01

7

0.2

18-Apr-03

18:09

20-Apr-03

17:02

7

0.3

18-Apr-03

18:09

20-Apr-03

17:02

8

0.2

18-Apr-03

18:11

20-Apr-03

17:03

9

0.9

18-Apr-03

18:12

20-Apr-03

17:05

10

0.4

18-Apr-03

18:12

20-Apr-03

17:06

11

0.4

18-Apr-03

18:13

20-Apr-03

17:06

12

0.4

18-Apr-03

18:14

20-Apr-03

17:07

13

0.2

18-Apr-03

18:16

20-Apr-03

17:10

14

0.4

18-Apr-03

18:17

20-Apr-03

17:11

16

0.3

18-Apr-03

18:22

20-Apr-03

17:13

17

0.4

18-Apr-03

18:28

20-Apr-03

17:17

18

0.2

18-Apr-03

18:25

20-Apr-03

17:14

18

0.2

18-Apr-03

18:25

20-Apr-03

17:14

19

0.2

18-Apr-03

18:24

20-Apr-03

17:14

20

0.5

18-Apr-03

18:31

20-Apr-03

17:20

21

0.6

18-Apr-03

18:32

20-Apr-03

17:21

blank

0.2

20-Apr-03

20:23

20-Apr-03

20:23

main office

0.3

18-Apr-03

18:33

20-Apr-03

17:22

 