Palos Verdes Intermediate School

The data collected at Palos Verdes Intermediate School are presented here. Figure 1 is a schematic of the school site that shows the rooms that were tested for indoor radon colored according to the amount of radon in the rooms. Figure 1 also show the approximate locations of the sites where field gamma-ray measurements were made. Table 1 lists the results of the field gamma-ray measurements. Samples of the top five inches of soil were collected at two of the gamma-ray sites and Table 2 lists the results of analyses of those samples. Table 3 lists the results of the indoor radon measurements.

 

Image of Palos Verdes Intermediate School site with radon and gamma-ray locations.

Figure 1. Schematic of rooms at Palos Verdes Intermediate School showing indoor radon levels and sites at which gamma-ray measurements were made.

 

Table 1. Results of gamma-ray spectrometer measurements at Palos Verdes Intermediate School. Site locations are indicated in Figure 1 (e.g. location number 1 refers to PVIP1). The column labeled "Group" identifies the group to which the measurement was assigned as a result of classification of the gamma-ray data.

 

Location

K

eU

eTh

Group

Latitude

Longitude

 

(%)

(ppm)

(ppm)

 

(degrees)

(degrees)

PVIP1

1.5

1.8

4.5

3

33.7766

-118.4115

PVIP2

1.2

2.5

4.2

3

33.7769

-118.4116

PVIP3

0.9

2.2

4.3

3

33.7766

-118.4120

PVIP4

1.3

2.1

4.0

3

33.7769

-118.4120

PVIP5

1.2

2.8

3.4

3

33.7767

-118.4128

PVIP6

1.3

2.4

4.6

3

33.7773

-118.4121

 

Table 2. Results of laboratory measurements of soil samples. The K, eU, and eTh concentrations were determined by a laboratory gamma-ray spectrometer and the field results are presented for comparison. Radon emanation fraction was determined as discussed in the section on methodologies.

 

Location

Laboratory

Field Spectrometer

Radon

Latitude

Longitude

 

K

eU

eTh

K

eU

eTh

Eman.

(degrees)

(degrees)

 

(%)

(ppm)

(ppm)

(%)

(ppm)

(ppm)

 

 

 

PVIP4

0.9

2.8

4.4

1.3

2.1

4.0

0.22

33.7769

-118.4120

PVIP6

1.1

3.4

6.4

1.3

2.4

4.6

0.24

33.7773

-118.4121

 

 

 

 

 

 

 

 

 

 

 

Bulk Density (g/cc)

Water Content

Porosity

 

 

 

PVIP4

1.08

22.3%

0.59

 

 

 

PVIP6

1.10

13.6%

0.59

 

 

 

 

 

Table 3. Results of indoor radon measurements in classrooms.

 

Room

Radon

Start

Stop

Number

(pCi/L)

Date

Time

Date

Time

602

0.2

14-Mar-03

16:16

16-Mar-03

16:09

603

0.4

14-Mar-03

16:14

16-Mar-03

16:07

610

0.2

14-Mar-03

16:13

16-Mar-03

16:06

701

0.2

14-Mar-03

16:18

16-Mar-03

16:10

703

0.2

14-Mar-03

16:19

16-Mar-03

16:11

708

0.6

14-Mar-03

16:20

16-Mar-03

16:13

710

0.2

14-Mar-03

16:22

16-Mar-03

16:14

710

0.3

14-Mar-03

16:22

16-Mar-03

16:14

711

0.2

14-Mar-03

16:23

16-Mar-03

16:15

801

0.3

14-Mar-03

16:31

16-Mar-03

16:21

802

0.2

14-Mar-03

16:32

16-Mar-03

16:22

803

0.2

14-Mar-03

16:33

16-Mar-03

16:23

804

0.2

14-Mar-03

16:34

16-Mar-03

16:24

808

0.2

14-Mar-03

16:26

16-Mar-03

16:16

809

1.0

14-Mar-03

16:27

16-Mar-03

16:17

810

0.6

14-Mar-03

16:28

16-Mar-03

16:25

811

0.2

14-Mar-03

16:29

16-Mar-03

16:20

812

0.2

14-Mar-03

16:30

16-Mar-03

16:20

904

0.4

14-Mar-03

16:11

16-Mar-03

16:05

905

0.2

14-Mar-03

16:10

16-Mar-03

16:02

906

0.8

14-Mar-03

16:08

16-Mar-03

16:01

906

1.1

14-Mar-03

16:08

16-Mar-03

16:01

908

0.4

14-Mar-03

16:06

16-Mar-03

16:00

Blank

0.2

16-Mar-03

20:23

18-Mar-03

20:23

 

[an error occurred while processing this directive]