Figure 5. A view of the two types of filter holders used on the McLane Water Transfer Systems. Prior to use, the top frits are removed from both types of filter holders. The top frits were found to pre-filter particles before they reached the filter paper resulting in erroneously low determinations of suspended matter concentrations (see Appendix 2.)
|